Overview
- Steel construction with gray powder-coat finish for corrosion resistance
- NEMA Type 12 rating for protection against dust, falling dirt, and light liquid splashing
- Dimensions: 60.00 x 37.38 x 16.00 inches for ample interior space
- Compatible with disconnect switches and circuit breakers from major manufacturers
- No pre-installed handle for flexible handle selection per application needs
- Removable door with continuous hinge
- Data pocket is high impact thermoplastic
- Oil-resistant gasket
- Collar studs for mounting optional panels
- Holes in body and door for mounting disconnect operating handle, operating mechanism, and door hardware
Specifications
Application | Controls and Drives; Arc Flash Safety; Power Distribution |
Color | Gray |
Conductive Panel | A60P36G |
Data Pocket Size | 305 x 305 mm |
Data Pocket Size | 12.00 x 12.00 in |
Depth | 16 IN |
Exterior Color | Gray |
Exterior Color Code | ANSI 61 |
Finish | Powder Coated |
Height | 60 in |
Interior Color | White |
IP Rating | IP65 |
Material | Steel |
Material | Mild Steel |
Modification Services | Yes |
Nema Rating | Type 12 |
NEMA Rating | 12 Indoor, dust-resistant |
Panel | A60P36 |
Panel Size | 57.00 x 33.00 in |
Panel Size | 1448 x 838 mm |
Protection Rating | NEMA Type 12 |
Series | nVent HOFFMAN Disconnect Enclosure |
Size | 60.00x37.38x16.00 in |
Size | 60.00x37.38x16.00 inches |
Thickness | 1.9 mm |
Thickness | 14 ga |
Type | Mild Steel Wall Mounted Industrial Disconnect Enclosures |
Type Number | Type 13 |
Weight | 105 lb |
Width | 37.38 |
Width | 949 |
With or Without Handle | Without |
Package Dimensions (L x W x H) | 64 IN x 40 IN x 18 IN |
Package Dimensions (L x W x H) | 162.56 cm x 101.6 cm x 45.72 cm |
Package Weight (Imperial) | 105.000 L |
Package Weight (Metric) | 47.628 kg |

LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install Hubs on the A60SA3816LP Enclosure
Instructions for installing watertight conduit hubs into the A60SA3816LP enclosure for secure and compliant electrical connections.
Estimated time: 30m
Tools needed:
Hole saw or Greenlee-type punch, Wrench (for hub manufacturer's instructions)
Supplies needed:
CSA approved, watertight, rigid conduit hubs
- Prepare Enclosure for Hub Installation
Determine the desired location for conduit entry (top, bottom, or side). Use a hole saw or Greenlee-type punch to cut the required hole size for the conduit hub. Refer to the provided table for recommended opening diameters based on the trade size of the conduit.
- Install Conduit Hub
Install the conduit hub according to the hub manufacturer's specific instructions. Ensure the hub is designed to fit the standard conduit opening and is CSA approved, watertight, and rigid.
- Ensure Panel Bonding
If securing the panel with nuts, install the enclosed external toothed lockwasher under one of the nuts. This ensures proper bonding between the panel and the enclosure.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.