Overview

The **nVent Type 4X Two-Door Floorstand Enclosure (SKU: A60H6018SSLPQT)** is a **60x60x18-inch stainless steel enclosure** designed to protect sensitive electronic controls, instrumentation, and automation components in demanding industrial environments. Constructed from **304 stainless steel** with a durable brushed finish, this enclosure resists corrosion, staining, and pitting, ensuring long-term performance in noncorrosive or mildly corrosive indoor and outdoor settings. Certified to **Type 4X/NEMA 4X, IP66, and UL 508A** standards, it provides superior resistance to dust, water, and hose-directed liquids, meeting NEMA Type 3R, 4, 4X, and 12 requirements. The **two-door design** with **quarter-turn latches** enables quick and secure access for maintenance, reducing downtime in critical operations. Ideal for industries such as **food & beverage processing, water & wastewater treatment, petroleum & chemical processing, and pharmaceutical manufacturing**, this enclosure safeguards control panels, PLCs, VFDs, and sensor arrays from moisture, chemicals, and mechanical stress. Its **floorstand mounting** allows flexible installation in tight spaces or integration into larger control systems. Pair with nVent accessories like gland plates and ventilation solutions for customized protection.
  • Floor-standing enclosure with 1/4 turn latching
  • Seams continuously welded and ground smooth
  • Flange trough collar on all four sides of door openings
  • Seamless foam-in-place one-piece gasket provides water-, oil- and dust-tight seal against contaminants
  • Black die-cast quarter-turn latches with slotted insert provided on three sides of each door
  • Concealed hinges provide 180-degree door opening and allow easy door removal and cleaning of hinge area
  • Bolt-on 12-in.-high stainless steel floor stands
  • Heavy-duty Type 316L stainless steel lifting eyes
  • Collar studs on inside of enclosure back for mounting optional panels
  • Removable centerpost for easy panel installation

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Body Thickness
2.8 mm
Body Thickness
12 ga
Body Thickness
16 ga
Color
Unpainted
Conductive Panel
A60P60G
Depth
459 mm
Depth
18.06
Depth
459
Door Thickness
14 ga
Door Thickness
1.98 mm
Finish
Brushed #4
Height
1,526 mm
Height
60.06
Height
1,526
IP Rating
IP66
Latch Quantity
10
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
NEMA Rating
12
NEMA Rating
12 Indoor, dust-resistant
Panel
A60P60
Panel Size
1422 x 1422 mm
Panel Size
56.00 x 56.00 in
Protection Rating
NEMA Type 12
Size
60.06x60.06x18.06 in
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 3R
Weight
473 lb
Width
60.06
Width
1,526
Width
1,526 mm
Package Dimensions (L x W x H)
68 IN x 38 IN x 81.5 IN
Package Dimensions (L x W x H)
172.72 cm x 96.52 cm x 207.01 cm
Package Weight (Imperial)
473.000 L
Package Weight (Metric)
214.553 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A903636SSFSDAN4 Controller

This guide provides step-by-step instructions for installing and configuring the A903636SSFSDAN4 Controller, ensuring proper wiring and setup for optimal performance.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Wire connectors, DIN rail clips

  1. Mount the controller

    Attach the A903636SSFSDAN4 Controller to the DIN rail using the provided clips. Ensure it is securely fastened and level.

  2. Connect the power supply

    Using wire connectors, connect the power supply wires to the designated terminals on the controller. Verify that the connections are tight and secure.

  3. Wire the input/output terminals

    Connect the input and output devices to the corresponding terminals on the controller. Use a multimeter to check for continuity and ensure proper connections.

  4. Configure the controller settings

    Power on the controller and access the configuration menu. Set the required parameters according to your application needs.

  5. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance. Adjust settings as necessary.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.