Overview

The nVent Allen-Bradley 1494 Cutout Disconnect Enclosure (SKU A60AB3816LP) is a Type 12, NEMA-rated enclosure designed to house Allen-Bradley Bulletin 1494F flange-mount disconnect switches and Bulletin 1494D flange-mount operators for circuit breakers. This heavy-duty steel enclosure measures 60 inches in height, 38 inches in width, and 16 inches in depth, providing ample space for complex disconnect switch configurations and associated wiring. The ANSI 61 gray powder-coated finish ensures durability in industrial environments, while the Type 12 rating (UL 508A Listed, cUL Listed per CSA C22.2 No. 94) protects against falling dirt and dripping or light-running water. The enclosure features a removable door with a continuous hinge, Type 12-rated door gasket, and external welded-on mounting brackets for easy installation. Pre-welded guide brackets, door catch, and locking bars simplify mounting of disconnect switches and operators. Ideal for motor control centers, machine tool applications, conveyor systems, and process control equipment, this enclosure ensures operational continuity and compliance with safety regulations. The enclosure is manufactured in the US and distributed by Gross Automation.
  • Holes provided in body and door for mounting disconnect switch, operating mechanism and door hardware
  • Type 12 rated door gasket
  • Seams continuously welded and ground smooth
  • Includes locking bar(s) for door hardware, spacers and screws to support disconnect panel, and instructions for installing disconnects
  • Collar studs provided for mounting optional panels
  • Removable door with continuous hinge
  • External mounting brackets
  • Data pocket is high impact thermoplastic
  • External-formed flange around all sides of enclosure opening
  • Guide bracket(s) and door catch welded to door

Specifications

Application
Power Distribution; Controls and Drives; Arc Flash Safety
Color
Gray
Conductive Panel
A60P36G
Data Pocket Size
305 x 305 mm
Data Pocket Size
12.00 x 12.00 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Interior Color
White
IP Rating
IP65
Material
Mild Steel
Material
Steel
Modification Services
Yes
Nema Rating
Type 12
NEMA Rating
12 Indoor, dust-resistant
Panel
A60P36
Panel Size
1448 x 838 mm
Panel Size
57.00 x 33.00 in
Series
1494
Size
60.00x37.38x16.00 in
Size
60x37x16 mm
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 13
Weight
180 lb
Package Dimensions (L x W x H)
64.5 IN x 38.5 IN x 18.25 IN
Package Dimensions (L x W x H)
163.83 cm x 97.79 cm x 46.355 cm
Package Weight (Imperial)
180.000 L
Package Weight (Metric)
81.648 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A60AB3816LP Enclosure

This guide provides step-by-step instructions for mounting and wiring the A60AB3816LP enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Level

Supplies needed:

Mounting screws, Metal shims, Terminal connectors

  1. Prepare the mounting surface

    Ensure the surface where the enclosure will be mounted is clean and level. Use a level to verify the surface is flat.

  2. Mount the enclosure

    Secure the enclosure to the wall or floor using appropriate fasteners in all mounting holes. Ensure it is level and firmly attached.

  3. Adjust door alignment

    If the door does not close properly, use metal shims to adjust the mounting feet until the door aligns evenly. Tighten all screws securely.

  4. Install terminal blocks

    Position the terminal blocks on the interior panel and secure them using the provided mounting hardware.

  5. Connect wiring

    Connect the electrical wiring to the terminal blocks according to the manufacturer's specifications. Ensure all connections are tight and secure.

  6. Verify connections

    Use a multimeter to check all electrical connections for continuity and proper voltage levels before powering on the enclosure.

  7. Calibrate the enclosure

    Follow the manufacturer's calibration procedures to ensure the enclosure operates within specified parameters.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.