The nVent Allen-Bradley 1494 Cutout Disconnect Enclosure (SKU: A60AB3812LP) is a robust Type 12 rated enclosure engineered to house Allen-Bradley Bulletin 1494F flange-mount disconnect switches. Constructed from durable 14-gauge steel with a protective ANSI 61 gray finish, this enclosure measures 60.00 x 37.38 x 12.00 inches. It meets stringent industry standards including UL 508A, cUL, NEMA/EEMAC Type 12, 13, and IEC 60529 IP65, providing reliable protection against dust and non-corrosive liquids. Key features include external welded-on mounting brackets for straightforward installation, a removable door with a continuous hinge and a Type 12 gasket for a secure seal, and collar studs for mounting optional panels. The enclosure is pre-drilled with holes for mounting operating handles and hardware. It is specifically designed for compatibility with fixed-depth Allen-Bradley devices up to the 1494F Series C. Supplied with guide brackets, a door catch, locking bars, and spacers for disconnect support, this enclosure ensures a secure and organized installation. Distributed by Gross Automation.
  • Type 12 rated enclosure for Allen-Bradley 1494F disconnect switches
  • Constructed from 14-gauge steel with ANSI 61 gray finish
  • Dimensions: 60.00 x 37.38 x 12.00 inches
  • Meets UL 508A, cUL, NEMA/EEMAC Type 12, 13, and IEC 60529 IP65 standards
  • Includes external mounting brackets, removable door with Type 12 gasket, and collar studs
  • Removable door with continuous hinge
  • External mounting brackets
  • Data pocket is high impact thermoplastic
  • External-formed flange around all sides of enclosure opening
  • Guide bracket(s) and door catch welded to door

Specifications

Application
Arc Flash Safety; Power Distribution; Controls and Drives
Color
Gray
Conductive Panel
A60P36G
Data Pocket Size
12.00 x 12.00 in
Data Pocket Size
305 x 305 mm
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Interior Color
White
IP Rating
IP65
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
External welded-on mounting brackets
Nema Rating
Type 12
Nema Rating
Type 12, 13
NEMA Rating
12 Indoor, dust-resistant
Panel
A60P36
Panel Size
1448 x 838 mm
Panel Size
57.00 x 33.00 in
Series
Allen-Bradley 1494
Series
1494F
Size
60.00x37.38x12.00 in
Size
60.00 x 37.38 x 12.00 inches
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 13
Weight
134 lb
Package Dimensions (L x W x H)
60 IN x 38 IN x 12 IN
Package Dimensions (L x W x H)
152.4 cm x 96.52 cm x 30.48 cm
Package Weight (Imperial)
134.000 L
Package Weight (Metric)
60.782 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the A60AB3812LP Controller

This guide provides step-by-step instructions for installing and wiring the A60AB3812LP Controller securely and correctly.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter, Hole saw or Greenlee-type punch

Supplies needed:

Mounting screws, External toothed lockwashers, Watertight conduit hubs

  1. Prepare the installation site

    Select an appropriate location for the controller, ensuring it is accessible and complies with local regulations. Use a hole saw or Greenlee-type punch to cut the required holes for conduit entry.

  2. Install the conduit hub

    Install a CSA approved, watertight conduit hub into the holes you have cut, following the manufacturer's instructions. Ensure the hub is securely fastened and watertight.

  3. Mount the controller

    Secure the A60AB3812LP Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  4. Connect wiring

    Connect the wiring to the controller according to the wiring diagram provided in the manual. Use terminal connectors as needed and ensure all connections are secure.

  5. Verify connections

    Use a multimeter to verify that all electrical connections are correct and that there are no short circuits before powering on the controller.

  6. Power on and configure

    Power on the A60AB3812LP Controller and follow the initial setup instructions in the manual to configure the device settings.

  7. Calibrate the controller

    Perform any necessary calibration procedures as outlined in the manual to ensure the controller operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.