The nVent A604808SSLP is a robust, two-door floorstand enclosure engineered for superior protection of critical industrial control and automation systems. Constructed from high-quality SS304 brushed stainless steel, this enclosure offers exceptional resistance to corrosion and harsh environmental conditions, making it an ideal choice for demanding applications across various industries. Its substantial dimensions of 60 inches high, 48 inches wide, and 8 inches deep provide ample space for housing large components, complex wiring configurations, and multiple sub-assemblies, ensuring efficient and organized system integration. The hallmark of the A604808SSLP is its advanced three-point latching mechanism. This system, combined with a continuous gasket seal, delivers industry-leading protection against ingress of dust, dirt, oil, and water, meeting Type 12 environmental ratings. This level of sealing is crucial for maintaining the operational integrity and longevity of sensitive electronic and electrical equipment, preventing costly downtime and maintenance. The dual-door design facilitates easy access for installation, maintenance, and operational adjustments without compromising the enclosure's protective integrity. Each door is designed for secure closure and can accommodate various locking mechanisms for enhanced security. Engineered by nVent, a globally recognized leader in electrical enclosure solutions, the A604808SSLP benefits from decades of expertise in designing and manufacturing reliable protective enclosures. This commitment to quality is evident in the meticulous construction and material selection, ensuring that the enclosure can withstand the rigors of industrial environments, including vibration, temperature fluctuations, and chemical exposure. The brushed stainless steel finish not only contributes to its aesthetic appeal but also enhances its durability and ease of cleaning. This enclosure is a critical component for any facility prioritizing system reliability and operational continuity. Key features and benefits of the nVent A604808SSLP include: * **Superior Environmental Protection:** Type 12 rating ensures protection against dust, dirt, oil, and water, safeguarding sensitive equipment. * **Robust Construction:** Fabricated from durable SS304 brushed stainless steel for exceptional corrosion resistance and longevity. * **Ample Interior Space:** Generous 60x48x8 inch dimensions accommodate large components and complex mounting setups. * **Secure Three-Point Latching:** Provides a tight seal and enhanced security for the enclosure's contents. * **Dual-Door Access:** Facilitates convenient installation, maintenance, and operational access. * **Trusted Manufacturer:** Designed and built by nVent, a leader in electrical enclosure solutions. This enclosure is ideally suited for applications in food and beverage processing, pharmaceuticals, chemical plants, water and wastewater treatment, and any other sector where stringent environmental controls and equipment protection are paramount. Its robust design and reliable sealing make it an indispensable asset for ensuring the uninterrupted operation of critical industrial systems. The UNSPSC code 39121324 further categorizes this product within the electrical equipment and component enclosures market, highlighting its specific industrial utility. Manufactured in the USA, it adheres to high production standards.
  • Seams continuously welded and ground smooth; no holes or knockouts
  • Strong, rigid construction with body stiffeners
  • Gasketed overlapping doors eliminate need for centerpost
  • Plated steel 3-point latching mechanism and key-locking handle
  • Heavy-gauge continuous hinges support each door
  • Data pocket, provided on door with 3-point latches, is high-impact thermoplastic
  • 12-in. (305-mm) floor stands are bolted to enclosure
  • Heavy-duty lifting eyes are Type 316 stainless steel
  • Panel supports
  • Collar studs for mounting optional panel

Specifications

Application
Controls and Drives;Corrosive Environments;Hygienic Environments
Application
Corrosive Environments; Controls and Drives; Hygienic Environments
Color
Unpainted
Color
Brushed
Depth
205 mm
Depth
8.06 in
Finish
Brushed #4
Galvanized Panel
A60P48G
Height
1,526 mm
Height
60.06
Height
1,526
IP Rating
IP55
IP Rating
IP66
Material
Stainless Steel 304
Material
Stainless Steel;Stainless Steel 304
Modification Services
Yes
Mounting Type
Floorstand
NEMA Rating
12 Indoor, dust-resistant
Nema Rating
Type 12
NEMA Rating
12
Panel
A60P48
Panel Gauge
11
Panel Size
1422 x 1118 mm
Panel Size
56.00 x 44.00 in
Protection Rating
NEMA Type 12
Size
60.06x48.06x8.06 in
Size
60x48x8
Stiffener Body
1
Stiffener Body
1 (X-form)
Thickness
51.40mm (2.024")
Thickness
12 ga
Thickness
2.78 mm
Type
Stainless Steel Freestanding Industrial Enclosures
Type Number
Type 12
Weight
345 lb
Width
1,221 mm
Width
48.06
Width
1,221
Package Dimensions (L x W x H)
56 IN x 34 IN x 81.75 IN
Package Dimensions (L x W x H)
142.24 cm x 86.36 cm x 207.645 cm
Package Weight (Imperial)
345.000 L
Package Weight (Metric)
156.492 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the WS62XM6312SS Enclosure

This guide provides step-by-step instructions for mounting and wiring the WS62XM6312SS enclosure securely.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Metal shims

  1. Mount the enclosure

    Secure the WS62XM6312SS enclosure to the wall or floor using proper fasteners in all mounting holes. Ensure the enclosure is level and firmly attached.

  2. Adjust door alignment

    If the enclosure is not level, place metal shims under the corners as needed to ensure the doors close evenly. Tighten all mounting screws securely.

  3. Install internal components

    Position the internal panel on the mounting studs and adjust any studs as necessary to fit the panel in place. Ensure all components are securely fastened.

  4. Connect electrical wiring

    Use terminal connectors to wire the internal components according to the manufacturer's specifications. Verify all connections with a multimeter to ensure proper functionality.

  5. Calibrate and test

    Once all components are installed and wired, power on the enclosure and perform a functionality test to ensure everything operates correctly.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.