Authorized nVent Distributor
nVent A30AB2610LP - Allen-Bradley 1494 Cutout Disconnect Enclosure Type 12, 30x25x10, Gray, Steel

nVent A30AB2610LP Allen-Bradley 1494 Cutout Disconnect Enclosure Type 12, 30x25x10, Gray, Steel

UPC: 783510326401


Documents & Media
Installation Instructions

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent Allen-Bradley 1494 Cutout Disconnect Enclosure (SKU A30AB2610LP) is a Type 12 gray steel enclosure designed to house Allen-Bradley Bulletin 1494F flange-mount disconnect switches and Bulletin 1494D flange-mount operators. This enclosure measures 30 inches in height, 25 inches in width, and 10 inches in depth, providing ample internal space for components and wiring. Its Type 12 rating ensures protection against falling dirt and dripping or light splashing of liquids, making it suitable for indoor industrial environments. The enclosure features a removable door with a continuous hinge and an oil-resistant gasket for secure sealing. It includes a preferred cutout compatible with major brand disconnect switches and circuit breakers, simplifying installation. Internal collar studs allow for the mounting of optional panels. The design incorporates external welded-on mounting brackets for easy installation and an external formed body flange that channels liquids away from critical areas. This enclosure is ideal for applications in manufacturing, food and beverage processing, and water/wastewater treatment facilities where reliable component protection is required.
  • Type 12 gray steel enclosure for indoor industrial use
  • 30" H x 25" W x 10" D dimensions for component housing
  • Removable door with continuous hinge and oil-resistant gasket
  • Preferred cutout compatible with major brand disconnect switches
  • Internal collar studs for optional panel mounting
  • Removable door with continuous hinge
  • External mounting brackets
  • Data pocket is high impact thermoplastic
  • External-formed flange around all sides of enclosure opening
  • Guide bracket(s) and door catch welded to door

Specifications

Application
Power Distribution; Arc Flash Safety; Controls and Drives
Color
Gray
Conductive Panel
A30P24G
Data Pocket Size
305 x 305 mm
Data Pocket Size
12.00 x 12.00 in
Exterior Color
Gray
Exterior Color Code
ANSI 61
Finish
Powder Coated
Interior Color
White
IP Rating
IP65
Material
Steel
Material
Mild Steel
Modification Services
Yes
Mounting Type
External welded-on mounting brackets
Nema Rating
Type 12
Nema Rating
Type 12, 13
NEMA Rating
12 Indoor, dust-resistant
Panel
A30P24
Panel Size
27.00 x 21.00 in
Panel Size
686 x 533 mm
Series
1494
Size
30x25x10
Size
30.00x25.38x10.00 in
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Disconnect Enclosures
Type Number
Type 13
Weight
65 lb
Package Dimensions (L x W x H)
34.75 IN x 26.5 IN x 12 IN
Package Dimensions (L x W x H)
88.265 cm x 67.31 cm x 30.48 cm
Package Weight (Imperial)
65.000 L
Package Weight (Metric)
29.484 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install the A30AB2610LP Controller

This guide provides step-by-step instructions for installing and configuring the A30AB2610LP Controller, ensuring proper mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the A30AB2610LP Controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use terminal connectors to connect the power and signal wires to the appropriate terminals on the controller. Ensure all connections are tight and secure.

  3. Verify connections

    Use a multimeter to check the voltage at the power terminals to ensure proper voltage levels are present. Confirm that all connections are correct before powering on the controller.

  4. Power on the controller

    Turn on the power supply to the controller and observe the indicator lights to ensure the unit is functioning correctly.

  5. Configure the controller settings

    Access the configuration menu via the controller's interface and set the necessary parameters according to your application requirements.

  6. Calibrate the controller

    Follow the calibration procedure outlined in the user manual to ensure accurate readings and performance of the controller.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.