Contact for Pricing
Overview
- Captivated stainless steel cover screws thread into sealed wells
- Oil-resistant gasket and adhesive
- Seams continuously welded and ground smooth
- No holes or knockouts
- Grounding stud on inside back of box
- 14 or 12 gauge G-90 grade galvanized steel bodies
- 12 or 10 gauge G-90 grade galvanized steel covers
Specifications
Application | Power Distribution |
Body Thickness | 16 ga |
Body Thickness | 14 ga |
Color | Unpainted |
Cover Screw Quantity | 8 |
Depth | 13 IN |
Depth | 12 in |
Depth, Maximum | 12 |
Depth, Minimum | 12 |
Door Thickness | 10 ga |
Door Thickness | 14 ga |
Finish | Galvanized |
Height | 44 IN |
Height | 20 in |
IP Rating | IP66 |
Material | Mild Steel;Steel |
Material | Steel |
Material | Galvanized Steel |
Modification Services | Yes |
Mounting Type | Screw-Cover Mounting |
NEMA Rating | 3 |
Nema Rating | Type 3 |
Protection Rating | NEMA Type 3 |
Series | A202012GSC |
Size | 20.00x20.00x12.00 in |
Size | 20.00x20.00x12.00 inches |
Type | Pull and Junction Boxes |
Type | Screw-Cover Pull Boxes Type 1/Type3 |
Type Number | Type 4 |
Weight | 46 lb |
Width | 508 mm |
Width | 20 IN |
Package Dimensions (L x W x H) | 23.25 IN x 21 IN x 14 IN |
Package Dimensions (L x W x H) | 59.055 cm x 53.34 cm x 35.56 cm |
Package Weight (Imperial) | 46.000 L |
Package Weight (Metric) | 20.866 kg |
How to Install the A202012GSC Controller
This guide provides step-by-step instructions for mounting and wiring the A202012GSC Controller securely.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Prepare the mounting location
Locate the mounting foot stud location using the provided dimensions. Use a center punch to mark the hole centers, and drill four 0.5 inch (13 mm) diameter holes.
- Install mounting feet
Insert sealing washers into the holes from the outside, ensuring the tapered cone is facing toward the hole. Then, insert the mounting foot studs through the sealing washers and turn the enclosure upright.
- Secure the controller
Thread nuts onto the mounting foot studs and tighten to 200 in-lbs. Ensure the controller is level and firmly attached to the mounting surface.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.