SolaHD SVL65100 - SVL Essential Din Rail Series, Nominal Output Voltage: 5VDC, Nominal Output Current: 6A, Max. Power: 30W, Frequency Rating: 50/62Hz, Single Phase, DIN Rail Mounting
SolaHD

SVL65100

UPC: 783472873197


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD SVL65100 is a DIN rail-mounted power rail from the SVL Essential Din Rail Series, engineered for industrial control panels and automation systems. This compact unit delivers a nominal output voltage of 5VDC at 6A, providing a maximum power output of 30W. Designed for single-phase operation at 50/62Hz, it ensures compatibility with a wide range of industrial equipment, including PLCs, motor drives, and safety-critical devices. The SVL65100 features robust construction for reliable performance in harsh environments, with built-in protection against over-current and thermal issues. Its DIN rail mounting system simplifies installation, reducing labor time and costs while maintaining a tidy control panel layout. The unit’s precise voltage regulation and low ripple output ensure stable power delivery, minimizing system downtime. Ideal for applications requiring compact, efficient power solutions, the SVL65100 is a trusted choice for engineers seeking dependable performance in industrial automation projects. Compatible with standard industrial power systems, this power rail supports modern control architectures while adhering to stringent reliability standards. The SVL65100 is part of SolaHD’s Essential Din Rail Series, a line of power supplies designed for high efficiency and durability in industrial settings. It meets key industry standards for safety and electromagnetic compatibility, ensuring reliable operation in diverse applications. The unit’s compact form factor and DIN rail mounting make it ideal for space-constrained installations, while its low power dissipation contributes to energy savings. With a wide input voltage range and stable output, the SVL65100 provides consistent performance across varying load conditions, supporting critical industrial processes.
  • Nominal output: 5VDC at 6A (30W max power)
  • Single-phase operation at 50/62Hz
  • DIN rail mounting for easy installation
  • Robust construction for harsh industrial environments
  • Built-in protection against over-current and thermal issues

Specifications

Amperage Rating
6 A
Application
ATM Machines;Heavy and Light Industrial Machinery;instrumentation;Scanners;Test and Measure Equipment;Vending Machines
Application
Heavy and Light Industrial Machinery; Test and Measure Equipment; Scanners; instrumentation; ATM Machines; Vending Machines;
Brand Name
SolaHD
Cable Size
Input Connector size range: 22-12 AWG (0.3-3.3 mm2) for solid conductors. Output: Connector size range: 18-12 AWG (0.82-3.3 mm2) for solid conductors
Efficiency
80 % typ
Enclosure
To be installed in an enclosure
Environmental Conditions
To be installed in a controlled environment
Frequency Rating
50/60 HZ
Frequency Rating, Maximum
60 Hz
Frequency Rating, Minimum
50 Hz
Fuse Rating
Internally Fused
Height
2.95 IN
Length
3.52 in
Material
Plastic
Mounting
DIN Rail
Phase
1
Phase
Single
Special Features
Convection cooling;DC OK LED;Protection: short circuit, over voltage, overload, over temperature;Two year warranty;Universal Input
Special Features
Universal Input; Convection cooling; DC OK LED; Protection: short circuit, over voltage, overload, over temperature; Two year warranty
Standard
CE: IEC/EN 60950-1 2nd edition CB Scheme;UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1;UL Recognized Component, ITE for US and Canada: UL 60950-1/CSA C22.2 60950-1 2nd edition
Standard
UL Listed, Industrial Control Equipment for US and Canada: UL 508, CSA C22.2 No. 107.1; UL Recognized Component, ITE for US and Canada: UL 60950-1/CSA C22.2 60950-1 2nd edition; CE: IEC/EN 60950-1 2nd edition CB Scheme
Sub Brand
Sola
Type
SVL Essential Din Rail Series
Voltage Rating
5 VDC
Wattage
30 W
Width
1.18 in
Package Dimensions (L x W x H)
3.52 IN x 1.18 IN x 2.95 IN
Package Dimensions (L x W x H)
8.9408 cm x 2.9972 cm x 7.493 cm
Package Weight (Imperial)
0.353 L
Package Weight (Metric)
0.160 kg
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz

3194213000K04

DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

Frequently Asked Questions

What is the operating temperature range for these power supplies?

The SVL series power supplies are designed to operate in an ambient temperature range of -20 °C to +70 °C.

What safety protections are included in the SVL series?

The SVL series includes protection against short circuit, over voltage, overload, and over temperature conditions.

What certifications do SVL power supplies have?

All SVL models are UL 508 Listed, UL 60950 Recognized, comply with EMC and Low Voltage Directives (IEC/EN60950-1), and are RoHS Compliant.

What is the warranty period for SVL power supplies?

All SVL series power supplies come with a two-year limited warranty.

Do all SVL models include a DC OK Relay Contact?

No, only SVL models with power ratings greater than 120 Watts include a DC OK Relay Contact. Models less than 120 Watts do not.

What are the dimensions of the SVL 1-24-100 model?

The SVL 1-24-100 model has dimensions of 2.95 in (75.0 mm) high, 0.82 in (21.0 mm) wide, and 3.52 in (89.5 mm) deep.

How does short circuit protection work?

Short circuit protection operates in hiccup mode and is non-latching, meaning it auto-recovers once the fault is removed.

What is the expected Mean Time Between Failures (MTBF)?

For <120W models, MTBF is >350 khrs. For >120W models, MTBF is >700 khrs, both at 115 Vac/230 Vac @ 25 °C.

What is the relative humidity operating condition?

The power supplies can operate in relative humidity from 5 to 95% RH, non-condensing.

What is the input voltage range for SVL power supplies?

The SVL series accepts an AC input voltage range of 85-264 Vac (100-240 Vac nominal) and a DC input range of 120-375 Vdc. The frequency is 50/60 Hz.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.