Contact for Pricing
Overview
- 2.5A current rating for low-current industrial control
- 120Vac single-phase operation with built-in surge protection
- Supports 26 AWG minimum wire size with secure #6 screw-terminal connections
- Suggested fuse/circuit breaker ampacity: 2.5A (max 3.125A)
- STFV Plus Series construction for durability and easy installation
Specifications
Application | Any situation where the available voltage must be changed to accommodate the voltage required by the specific electrical circuit or connected equipment. |
Brand Name | SolaHD |
Connector | # 6 Screw, Minimum Wire Size 26 |
Enclosure | NEMA 3R with optional weather shield (WS-30) |
Frequency Rating | 60 HZ |
Height | 1.81 |
Input | 120, Single Phase |
Insulation | 220 DEG Insulation System |
KVA Rating | 75 KVA |
Length | 22 IN |
Mounting | Wall Mounting Brackets Available |
Number Of Taps | 2 |
Phase | 3 |
Primary Voltage | 480 VAC |
Secondary Voltage | 208/120 VAC |
Special Features | Primary Amperage 90.3A, Secondary Amperage 208A, 220 DEG C Insulation System, Stainless Steel Material, No Electrostatic Shield |
Standard | UL Listed E25872 |
Style | Panel Mount |
Temperature Rating | 150 DEG C Rise |
Type | Ventilated Distribution Transformer |
Width | 28 IN |
Winding | Copper |
Package Dimensions (L x W x H) | 5.6 IN x 9 IN x 2.8 IN |
Package Dimensions (L x W x H) | 14.224 cm x 22.86 cm x 7.112 cm |
Package Weight (Imperial) | 1.450 L |
Package Weight (Metric) | 0.658 kg |

63-13-150-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-23-220-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-23-215-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-23-612-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-23-730-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-23-250-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
63-13-230-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
63-29-315-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
63-28-315-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
63-23-650-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-29-310-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US, UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
63-23-150-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240Frequently Asked Questions
What is the response time of the STFV Plus Series?
The STFV Plus Series has a response time of less than 5 nanoseconds.
What is the maximum peak surge current capability?
The peak surge current capability is 13,000 Amps per phase (8x20 μs). Line to Neutral, Line to Ground, and Neutral to Ground are each 6,500 Amps.
What is the primary function of the STFV Plus Series?
The STFV Plus Series combines SolaHD Tracking filtration for low-energy noise and surge protection for high-energy transients. It continuously tracks the input AC power line.
What noise reduction capabilities does the STFV Plus offer?
The STFV Plus attenuates high-frequency noise to a maximum of -90 dB. This reduction occurs in a frequency range of 100 kHz to 50 MHz.
What surge protection standards does this product meet?
The STFV Plus provides IEEE C62.41 Category A and B Ringwave protection. It is also designed to meet UL 1283 for Electromagnetic Interference Filters.
What are the operating temperature limits for this device?
The operating temperature range for the STFV Plus Series is from -40 °C to +60 °C (-40 °F to +140 °F) at full load.
What is the warranty period for the STFV Plus Series?
The STFV Plus Series comes with a ten-year limited warranty.
Does the STFV Plus Series require regular maintenance?
No, these devices are designed for years of trouble-free operation and require little or no operator intervention after installation.
What certifications does the STFV Plus Series hold?
The product is Certified to CSA C22.2 No. 8, UL Recognized Component to UL 1283, and is RoHS Compliant.
What are the case dimensions for the STFV025-10N model?
The case dimensions for the STFV025-10N are 4.00 in x 2.88 in x 1.81 in.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.