SolaHD STFV025-10N - STFV Plus Series Actibe Tracking with Surge Protection, Amps: 2.5, Min Wire Size: 26 AWG, Single Phase, 120 Vac, Screw Size: #6, Fuse/Circuit Breaker Ampacity: Suggested - 2.5 A, Maximum 3.125 A
SolaHD

STFV025-10N

UPC: 783472700325


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD STFV025-10N is a single-phase 120Vac actuator designed for precise low-current control in industrial environments. Rated at 2.5A, it supports minimum wire size 26 AWG with secure #6 screw-terminal connections, ensuring low-resistance, reliable bonds for long-term performance. Built-in surge protection shields connected equipment from transient voltage spikes, extending actuator lifespan and maintaining operational stability. The STFV Plus Series construction delivers durable, easy-to-install components suitable for control panels, automation systems, and legacy system upgrades. With a suggested fuse/circuit breaker ampacity of 2.5A and a maximum of 3.125A, the STFV025-10N integrates seamlessly into existing 120Vac power supplies. Ideal for applications requiring dependable actuation with minimal maintenance, this actuator combines robust engineering with compliance to industrial standards. Its compact design and compatibility with standard wiring practices reduce installation complexity and operational costs. The STFV025-10N is part of the STFV Plus Series, which features Active Tracking with Surge Protection. This specific model operates on a single phase at 120 Vac and has an amperage rating of 2.5A. The minimum wire size it accommodates is 26 AWG. For secure connections, it utilizes #6 screws. The suggested fuse or circuit breaker ampacity for this actuator is 2.5A, with a maximum allowable ampacity of 3.125A.
  • 2.5A current rating for low-current industrial control
  • 120Vac single-phase operation with built-in surge protection
  • Supports 26 AWG minimum wire size with secure #6 screw-terminal connections
  • Suggested fuse/circuit breaker ampacity: 2.5A (max 3.125A)
  • STFV Plus Series construction for durability and easy installation

Specifications

Application
Any situation where the available voltage must be changed to accommodate the voltage required by the specific electrical circuit or connected equipment.
Brand Name
SolaHD
Connector
# 6 Screw, Minimum Wire Size 26
Enclosure
NEMA 3R with optional weather shield (WS-30)
Frequency Rating
60 HZ
Height
1.81
Input
120, Single Phase
Insulation
220 DEG Insulation System
KVA Rating
75 KVA
Length
22 IN
Mounting
Wall Mounting Brackets Available
Number Of Taps
2
Phase
3
Primary Voltage
480 VAC
Secondary Voltage
208/120 VAC
Special Features
Primary Amperage 90.3A, Secondary Amperage 208A, 220 DEG C Insulation System, Stainless Steel Material, No Electrostatic Shield
Standard
UL Listed E25872
Style
Panel Mount
Temperature Rating
150 DEG C Rise
Type
Ventilated Distribution Transformer
Width
28 IN
Winding
Copper
Package Dimensions (L x W x H)
5.6 IN x 9 IN x 2.8 IN
Package Dimensions (L x W x H)
14.224 cm x 22.86 cm x 7.112 cm
Package Weight (Imperial)
1.450 L
Package Weight (Metric)
0.658 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-220-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:21000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-215-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-612-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-730-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:3000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-250-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:5000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug

63-13-230-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:3000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) L5-30R Receptacle, (1) NEMA L5-30 Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-315-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240

63-28-315-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-650-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US, UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-310-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US, UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

Frequently Asked Questions

What is the response time of the STFV Plus Series?

The STFV Plus Series has a response time of less than 5 nanoseconds.

What is the maximum peak surge current capability?

The peak surge current capability is 13,000 Amps per phase (8x20 μs). Line to Neutral, Line to Ground, and Neutral to Ground are each 6,500 Amps.

What is the primary function of the STFV Plus Series?

The STFV Plus Series combines SolaHD Tracking filtration for low-energy noise and surge protection for high-energy transients. It continuously tracks the input AC power line.

What noise reduction capabilities does the STFV Plus offer?

The STFV Plus attenuates high-frequency noise to a maximum of -90 dB. This reduction occurs in a frequency range of 100 kHz to 50 MHz.

What surge protection standards does this product meet?

The STFV Plus provides IEEE C62.41 Category A and B Ringwave protection. It is also designed to meet UL 1283 for Electromagnetic Interference Filters.

What are the operating temperature limits for this device?

The operating temperature range for the STFV Plus Series is from -40 °C to +60 °C (-40 °F to +140 °F) at full load.

What is the warranty period for the STFV Plus Series?

The STFV Plus Series comes with a ten-year limited warranty.

Does the STFV Plus Series require regular maintenance?

No, these devices are designed for years of trouble-free operation and require little or no operator intervention after installation.

What certifications does the STFV Plus Series hold?

The product is Certified to CSA C22.2 No. 8, UL Recognized Component to UL 1283, and is RoHS Compliant.

What are the case dimensions for the STFV025-10N model?

The case dimensions for the STFV025-10N are 4.00 in x 2.88 in x 1.81 in.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.