SolaHD STF0300-10Y - STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5 A, Three Phase (120.208 Vac wye)
SolaHD

STF0300-10Y

UPC: 783472700134


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD STF0300-10Y Active Tracking Filter is a critical component for ensuring stable and reliable three-phase power in industrial settings. This filter operates at a 120.208 VAC Wye voltage rating and a 30 A current rating, making it suitable for a variety of demanding applications. It is cULus Listed, UL1283 certified, and compliant with CSA C22.2 No. 8, guaranteeing adherence to stringent safety and performance standards. The STF Series filter is designed with a minimum wire size requirement of AWG 10, facilitating straightforward installation into existing electrical infrastructure. For protection, it suggests a 30 A fuse or circuit breaker, with a maximum allowable ampacity of 37.5 A, offering flexibility for potential future load expansions. The active tracking technology within this filter continuously monitors load conditions, providing precise voltage regulation and robust protection against transient disturbances. This proactive approach helps to prevent equipment damage, reduce downtime, and improve overall system efficiency. Its rugged construction ensures durability in industrial environments, and low maintenance requirements contribute to long-term operational reliability. Applications for the STF0300-10Y include manufacturing lines, data centers, and any industrial operation where consistent, high-grade power delivery is essential for sensitive equipment and continuous processes. Trust SolaHD's commitment to quality for dependable power conditioning.
  • Three-Phase Active Tracking Filter for industrial power conditioning
  • 120.208 VAC Wye Voltage Rating
  • 30 A Current Rating
  • cULus Listed, UL1283, CSA C22.2 No. 8 Certified
  • Minimum Wire Size AWG 10; Suggested 30A Fuse/Breaker (Max 37.5A)

Specifications

Package Dimensions (L x W x H)
20.1 IN x 17.9 IN x 10.8 IN
Package Dimensions (L x W x H)
51.054 cm x 45.466 cm x 27.432 cm
Package Weight (Imperial)
34.750 L
Package Weight (Metric)
15.763 kg
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (120.208 Vac wye)

STF2000-10Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (120.208 Vac wye)
Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 208, Vac Output 208Y/120, 60 Hz

63TAA330

Solatron Plus Series Three Phase Power Conditioners, Standard: UL (Canada and US), UL 1012, CSA C22.2 No. 125, Output: 30kVA, Vac Input 208, Vac Output 208Y/120, 60 Hz
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (120.208 Vac wye)

STF0150-10Y

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (120.208 Vac wye)
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240

63-29-250-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480/600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240

63-28-315-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240

63-28-310-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-810-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:10000VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240

63-28-775-8

MCR Hardwired Series, Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:7500VA, Input Voltage: 220/240/380/415, Output Voltage: 110/120/220/240
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0 2, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (240 V Delta)

STF2000-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0 2, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (240 V Delta)

STF1000-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 100.0, Minimum Wire Size AWG 2, Fuse/Circuit Breaker Ampacity: Suggested 100A, Maximum 125A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (240 V Delta)

STF0300-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (240 V Delta)
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (240 V Delta)

STF0500-24D

STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 50.0, Minimum Wire Size AWG 4, Fuse/Circuit Breaker Ampacity: Suggested 50A, Maximum 62.5A, Three Phase (240 V Delta)

Frequently Asked Questions

What is the purpose of the STF Series filter?

The STF Series filters provide clean AC power by eliminating lower voltage, high frequency noise caused by machinery and equipment. They guard against damaging lower energy transients.

What type of noise does the STF Series filter reduce?

The STF Series eliminates low voltage/high frequency noise, attenuating it to a minimum of 40dB in a frequency range of 50 KHz to 50 MHz.

What are the electrical specifications for STF0300-10Y?

The STF0300-10Y is a three-phase model for 120/208 Vac wye systems, rated for 30.0 Amps. It requires a minimum wire size of 10 AWG.

What is the suggested fuse or circuit breaker for STF0300-10Y?

The suggested fuse or circuit breaker ampacity for the STF0300-10Y is 30A, with a maximum of 37.5A.

What are the dimensions and weight of the STF0300-10Y?

The case dimensions are 14.00 x 12.00 x 6.00 inches. The mounting flange dimensions are 14.75 x 10.0 x 15.5 inches. The unit weighs 35.0 lbs.

What is the operating temperature range for STF filters?

STF filters operate from -40°C to +45°C. They can be derated linearly to 60% at +70°C.

What is the warranty period for SolaHD STF Series products?

SolaHD STF Series products come with a ten-year limited warranty.

What certifications does the STF Series hold?

The STF Series is UL 1283 Listed, CSA C22.2 No. 8 compliant, and RoHS Compliant.

What kind of enclosure does the STF0300-10Y use?

The STF0300-10Y, being a three-phase unit, is housed in a NEMA 12 enclosure.

What is the expected lifespan (MTBF) of STF filters?

The Mean Time Between Failure (MTBF) for STF filters is greater than 100,000 hours, according to Mil Std. 217F.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.