Contact for Pricing
Overview
- 10,000VA (10kVA) power rating
- 120 dB common-mode noise attenuation
- 60 dB transverse-mode noise attenuation
- Galvanic isolation for enhanced safety
- Input: 208/240/480 VAC; Output: 120/208/240 VAC
- UL (Canada and US), UL 1012, CSA, ANSI/IEEE C62.41 certified
Specifications
Application | Best choice when 80% or more of the load components are electromagnetic |
Brand Name | SolaHD |
Connection | Terminals |
Frequency Rating | 50/60 HZ |
Height | 8 IN |
Input | 208, 240, 480 |
Input Voltage | 243 x 480 Volt Primary, 230 x 460 Volt Primary, 220 x 440 Volt Primary VAC |
Insulation | 105 DEG C Insulation System |
Length | 12 IN |
Mounting | Mtg Width 8.00, Mtg Depth 8.75, Slot Size .44 x .69 IN |
Noise Level | 35 to 65 |
Output Power | 120, 208, 240 |
Output Voltage | 120, 115, 110 VAC |
Special Features | High Quality Silicon Steel Core, Meets or exceeds electrical requirements of NEMA, ANSI, NMTBA and JIC. |
Standard | UL Listed: E77014, UL 506; CSA Certified: LR-14328-4, CSA C22.2 No. 66. RoHS Compliant |
Style | 2 |
Temperature Rating | 55 DEG C Temperature Rise Under Full Load |
Type | SBE Open Style, Copper Wound |
Voltage Rating | 208/240/480 VAC (Input), 120/208/240 VAC (Output) |
Wattage | 5 KVA |
Width | 9 IN |
Package Dimensions (L x W x H) | 31 IN x 34 IN x 16 IN |
Package Dimensions (L x W x H) | 78.74 cm x 86.36 cm x 40.64 cm |
Package Weight (Imperial) | 428.000 L |
Package Weight (Metric) | 194.141 kg |

63-13-070-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:70VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-28-315-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:15000VA, Input Voltage: 208/240/480, Output Voltage: 120/208/240
63-13-215-6
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
63-23-612-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:120VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
63-23-720-8
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
STF0150-24D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 15.0, Minimum Wire Size AWG 14, Fuse/Circuit Breaker Ampacity: Suggested 15A, Maximum 18.75A, Three Phase (240 V Delta)
STF2000-24D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 200.0, Minimum Wire Size AWG 3/0 2, Fuse/Circuit Breaker Ampacity: Suggested 200A, Maximum 250A, Three Phase (240 V Delta)
STF0300-24D
STF Series Active Tracking Filter, cULus Listed, UL1283, CSA C22.2 No. 8, Amps 30.0, Minimum Wire Size AWG 10, Fuse/Circuit Breaker Ampacity: Suggested 30A, Maximum 37.5A, Three Phase (240 V Delta)Frequently Asked Questions
What is the SolaHD MCR Hardwired Series used for?
The SolaHD MCR Hardwired Series provides noise filtering and surge protection to safeguard connected equipment from damage, degradation, or misoperation. It also offers excellent voltage regulation.
What is the output voltage regulation for 60 Hz MCR units?
For 60 Hz MCR units, the output voltage regulation is ±3%.
What are the noise attenuation levels of this product?
The product offers 120 dB common mode and 60 dB transverse mode noise attenuation.
What surge protection capabilities does the MCR series offer?
The MCR series provides surge protection with less than 10 V let through typical, tested to ANSI/IEEE C62.41 Class A & B Waveform.
Does the SolaHD MCR Hardwired Series require maintenance?
No, the SolaHD MCR Hardwired Series does not require any maintenance.
What is the typical Mean Time Between Failure (MTBF)?
The typical Mean Time Between Failure (MTBF) for the MCR series is 25 years.
What are the input voltage options for product 63-28-310-8?
Product 63-28-310-8 accepts input voltages of 208V, 240V, or 480V.
What are the output voltage options for product 63-28-310-8?
Product 63-28-310-8 provides output voltages of 120V, 208V, or 240V.
What is the VA rating of the 63-28-310-8 product?
The 63-28-310-8 product has a VA rating of 10000 VA.
What are the dimensions of the 63-28-310-8 unit?
The 63-28-310-8 unit has a height of 28 in, a width of 26 in, and a depth of 9 in.
Frequently Asked Questions about SolaHD
What certifications and standards do SolaHD products comply with?
SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.
What industries and applications are SolaHD products used for?
SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.
What technical support does SolaHD offer?
SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.
What are the main product lines offered by SolaHD?
SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.
What are the key features of SolaHD products?
SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.
What environmental ratings do SolaHD products have?
SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What accessories are available for SolaHD products?
SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.
How are SolaHD products typically installed?
SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.