SolaHD SDU2024 - SDU 20-24 DIN Rail DC UPS power module, 24 Vdc / 20 A, 480 VA. Battery module required: SDU 24-BAT (DIN rail/panel mount, up to 4) or SDU 24-BATEM (external mount, 1 only) - one model only, not combined. Designed for use with SolaHD SDN Series 24 Vdc power supplies. Features: 16 to 12 AWG wire range, -20 to 50 DEG C operating temperature. Standards: UL (Canada and US), UL E61379, UL 508, CE: IEC/EN 60950-1. Optional: SDU24EXTBC6 6 ft battery cable, SDU 24-DB9 interface kit, SDU-PMBRK mounting brackets.

SolaHD SDU2024 SDU 20-24 DIN Rail DC UPS power module, 24 Vdc / 20 A, 480 VA. Battery module required…

UPC: 783472604029


Documents & Media
Specification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Needed to run SDU2024
Choose 1 24 Vdc power supply
Show all 6
Already have these? You don't need to buy them here.

Overview

The SolaHD SDU2024 is the 20 A power module of the SDU DIN Rail DC UPS system: it keeps 24 Vdc control loads running when the upstream supply fails. An SDU system has three parts - a 24 Vdc power supply (SolaHD recommends its SDN Series), this UPS power module, and a battery module, which is required. Choose one battery model: up to four SDU 24-BAT modules for DIN rail or panel mounting in a ventilated enclosure, or one SDU 24-BATEM external battery module. The module rates 480 VA at 24 Vdc / 20 A, takes 16 to 12 AWG wire, operates from -20 to 50 C, and is UL 508 listed. Charging is automatic when input DC power is present; on power failure it switches to battery back-up. Options include a 6 ft battery cable (SDU24EXTBC6), a relay-to-DB9 interface kit (SDU 24-DB9) and chassis mounting brackets (SDU-PMBRK).
  • 240Vdc Voltage Rating
  • 20A Amperage Rating
  • DIN Rail Mounting
  • IP20 Enclosure
  • UL (Canada and US), UL E61379, UL 508, CE: IEC/EN 60950-1 Certified

Specifications

Application
Industrial/Machine Control, Automation Process Control, Material Handling, Packaging Equipment
Back-Up Time
4
Battery Type
Sealed, Maintenance Free Lead Acid
Connection Type
16 to 12 AWG Wire Range
Current Rating
20 A
Enclosure
IP20
Environmental Conditions
0 to 95 Humidity Range
Height
4.88 in
Height
123.952 mm
IP Rating
IP20
Length
4.55 in
Length
115.57 mm
Mounting
DIN Rail
Mounting Type
DIN Rail
Special Features
Modular Rugged Industrial Design, Operating Temperature -20 to 50 DEG C, LED Status Indicator, Input Voltage 22.5 to 30 VDC, Output Current Rating 20A
Standard
UL (CANADA AND US), UL 508, UL 60950-1, CUL, CSA-C22.2, CE
Type
SDU Series, Direct Current Uninterruptible Power Supply System
Voltage Rating
240 VDC
Voltage Rating
24 VDC
Width
3.02 in
Width
76.708 mm
Package Dimensions (L x W x H)
7 IN x 5 IN x 6.5 IN
Package Dimensions (L x W x H)
17.78 cm x 12.7 cm x 16.51 cm
Package Weight (Imperial)
2.000 L
Package Weight (Metric)
0.907 kg
SDU Series optional interface kit to convert relay contacts signal to DB9 signals

SDU24DB9

SDU Series optional interface kit to convert relay contacts signal to DB9 signalsVerified fit
SDU Series optional 6 Foot Battery Module cable to 24 V DC UPS

SDU24EXTBC6

SDU Series optional 6 Foot Battery Module cable to 24 V DC UPSVerified fit
SDU Series DIN Rail AC UPS: Mounting Brackets to secure UPS to Wall, back of panel or enclosure

SDU-PMBRK

SDU Series DIN Rail AC UPS: Mounting Brackets to secure UPS to Wall, back of panel or enclosureVerified fit

Frequently Asked Questions

What is the input voltage range for the SDU DC UPS?

The SDU DC UPS operates with an input voltage range of 22.5 to 30.0 Vdc.

Can the SDU DC UPS battery be installed externally?

Yes, an external battery module (SDU 24-BATEM) allows placement outside non-ventilated enclosures while sealing electronics inside.

Does the SDU DC UPS have a self-test feature?

Yes, the SDU DC UPS includes an automatic self-test feature that checks the UPS and battery functions.

How does the SDU DC UPS indicate a bad battery?

If the battery is no longer useful, the UPS will sound an alarm and an LED indicator will illuminate.

What is the operating temperature range for the power module?

The power module has a wide operating temperature range of -20°C to +50°C.

What components are needed for an SDU DC UPS system?

An SDU DC UPS system requires a 24 Vdc power supply, an SDU DC UPS power module, and an SDU DC UPS battery module.

What types of battery modules are available for the SDU DC UPS?

Two models are available: SDU 24-BAT for DIN Rail/Panel mount in ventilated enclosures, and SDU 24-BATEM for external panel mount in non-ventilated enclosures.

Can different SDU DC UPS battery module types be combined?

No, only one model of the battery module can be connected to the SDU DC UPS at a time.

What is the typical backup time for SDU DC UPS at full load?

The SDU 10-24 provides 14 minutes, and the SDU 20-24 provides 4 minutes of backup time at full load with one battery module.

How long does it take to recharge SDU DC UPS batteries?

Typical recharge time to 90% capacity is 8 hours for one battery module, 24 hours for two, and 12 hours for each additional module.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.