SolaHD GLS64 - Single Output Switcher, CSA Certified, ITE, CSA C22.2 CSA 60950, CE IEC60950-1, UL Recog. Component for Canada and US, ITE UL60950-1, Input Voltage: 85-264 Vac, 120-300 Vdc, Output 1: 15 V at 4 A (5.3 A) Floating Output
SolaHD

GLS64

UPC: 783472170470


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD GLS64 Single Output Switcher (SKU: GLS64) is engineered for critical industrial control applications requiring reliable and safe power. This compact unit boasts comprehensive CSA and UL certifications, including CSA C22.2, ITE, CSA 60950, CE IEC60950-1, UL Recognized Component for Canada and US, and ITE UL60950-1, ensuring compliance with stringent safety standards for both North American markets. Its versatile input voltage range accepts 85-264 Vac or 120-300 Vdc, providing flexibility for various power sources commonly found in industrial settings. The GLS64 delivers a stable 15V floating output at a continuous 4A, with a peak capability of 5.3A. This floating output is crucial for sensitive electronics as it eliminates a ground reference, preventing ground loops and ensuring signal integrity. The robust construction and precise voltage regulation of the GLS64 contribute to its longevity and minimize downtime, even in challenging industrial environments. It is an ideal power solution for Programmable Logic Controllers (PLCs), motor drives, sensor interfaces, and other essential automation equipment. The GLS64 offers a cost-effective and space-saving design, simplifying integration into existing control panels with clear labeling and straightforward mounting. Engineers and technicians can rely on the GLS64 to meet demanding safety and performance requirements while maintaining operational efficiency. Key specifications include: Input Voltage: 85-264 Vac, 120-300 Vdc; Output 1: 15 V at 4 A (5.3 A peak) Floating Output. UNSPSC Code: 39121004.
  • CSA and UL Certified for Canada and US (CSA C22.2, ITE, UL60950-1, IEC60950-1)
  • Wide Input Voltage Range: 85-264 Vac / 120-300 Vdc
  • Stable 15V Floating Output at 4A (5.3A Peak)
  • Compact, Single Output Design for Space-Saving Integration
  • Ideal for PLCs, Motor Drives, and Sensor Interfaces

Specifications

Application
For use in industrial and medical applications requiring standard footprint size and very high reliability
Brand Name
SolaHD
Current Rating
4 A (5.3 A peak)
Efficiency
70 PCT typical at full load
Environmental Conditions
Storage: -40 DEG C to +85 DEG C; Operating: 0 DEG to 50 DEG C ambient. Derate each output 2.5 PCT per degree from 50 DEG to 70 DEG C, -20 DEG C start up.
Frequency Rating
47-63 HZ
Series
GLS
Standard
Non-Medical: EN60950, UL UL60950 E132002, CSA 22.2-234 Level 3 LR53982C, CB Certificate and report, CE Mark (LVD), Medical: UL 2601, CSA 22.2 No. 601.1, EN 60601-24
Type
GL Series Single & Multi Output Switchers
Voltage Rating
85-264 Vac/120-300 Vdc
Voltage Rating
85-264 Vac, 120-300 Vdc
Package Dimensions (L x W x H)
5.7 IN x 3.5 IN x 2.1 IN
Package Dimensions (L x W x H)
14.478 cm x 8.89 cm x 5.334 cm
Package Weight (Imperial)
0.750 L
Package Weight (Metric)
0.340 kg
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
N3 SCREW COVER - 10X10X6 - GRA

C3SC10106GY

N3 SCREW COVER - 10X10X6 - GRA
ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module

ACS380-040S-07A2-4

ACS380 AC Drive, 3-380-480V In, 3HP, 6A, Type OPEN, 1.5 overload, Integrated, HxWxD 6.69x2.76x7.52 in, Module
BK63H 1P B2A 10kA 120/240VAC UL1077

0626030563

BK63H 1P B2A 10kA 120/240VAC UL1077
MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)

1338006700

MC-50a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC50A-30-11-K7-S-E)
GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)

1270040900

GMD-16M DC240V 3W 1b EXP (GMD16M-30-01-UD-3W-S-E)
Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.

1SNK705010R0000

Combine high performance with compact dimensions: - 1000 V AC / DC IEC 600 V UL, - Opt for the best marking visibility thanks to the up-front, flat marker zone, which lets you mark up to eight digits or increase the font size.
Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699

CR104PXN1B

Pushbuttons. 104P heavy duty Oiltight Pushbutton. Nameplate. XN1B PR.No. CR100699
C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A

XT2NU3090BFF000XXX

C.BREAKER TMAX XT2N 125 UL/CSA FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMA R 90 I3=450...900 A
The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.

NNC75X75WH2

The NNC75X75WH2 Halogen-Free Wide Slot Wiring Duct is used to route, protect, and manage wires near sensitive electronic equipment and in environments where heat resistance or public safety is a concern. UL 94 flame class of V-0 with a UL recognized continuous-use temperature up to 95 C (203 F). Halogen-Free, Polyphenylene Oxide (PPO). Mounting holes provided. 2.85" x 2.97" (72.4 mm x 75.4 mm) and 6.6' (2 m) long. Cover included. Color White. 5 pieces per package.
DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz

3194213000K04

DS9 RECEPTACLE POLY BLUE SIZE 5 IP 66/67/69 3P+G 150 A 480 VAC 60 Hz
HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

C2G0150MQMJ

HPS Open Style Control Transformer, 150VA 240x480V-120x240V 50/60Hz

Frequently Asked Questions

What is the output voltage and current for the GLS64?

The GLS64 provides a 15 V output at 4 A. This rating increases to 5.3 A when 30 CFM of air is provided.

What is the input voltage range for the GLS64?

The GLS64 operates with an input voltage range of 85-264 Vac or 120-300 Vdc.

What is the operating temperature range for the GLS64?

The GLS64 operates from 0°C to 50°C ambient at full power. Derated operation is possible up to 70°C, with a -20°C start-up capability.

What is the warranty period for the GLS64?

The GLS64 comes with a two-year limited warranty.

What safety approvals does the GLS64 have?

The GLS64 has extensive safety approvals including UL 60950-1, CSA C22.2 CSA 60950-1, IEC60950-1, EN60950, cRUus, and CE Mark (LVD).

Does the GLS64 have overload protection?

Yes, the GLS64 features short circuit protection on all outputs and primary overload protection.

What is the typical efficiency of the GLS64?

The typical efficiency for the GLS64 at full load is 70%.

What is the Mean Time Between Failures (MTBF) for GLS64?

The demonstrated MTBF for the GLS64 is greater than 550,000 hours at full load and 25°C ambient conditions.

Does the GLS64 include EMI filtering?

Yes, the GLS64 has built-in EMI filtering and meets FCC Class B, CISPR 22 Class B, and EN55022 Class B standards.

What is the adjustment range for the main output of GLS64?

The main output of the GLS64 has an adjustment range of -5% to +10% minimum.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.