SolaHD 63-23-710-8 - Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
SolaHD

63-23-710-8

UPC: 783472222056


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The SolaHD 1000VA power conditioner (SKU 63-23-710-8) delivers industry‑leading noise suppression and safety for demanding industrial environments. With 120 DB common‑mode and 60 DB transverse‑mode noise attenuation, it effectively eliminates electromagnetic interference from both common‑mode and transverse sources, ensuring clean, reliable power to sensitive equipment. Galvanic isolation protects against ground loops and stray currents, while the UL/CSA certification (Canada and US) confirms compliance with the highest safety standards. Designed for flexibility, it supports a wide range of input voltages (110 / 120 / 220 / 240 / 380 / 415 VAC) and outputs 110 / 120 / 220 / 240 VAC, making it suitable for multi‑voltage installations. The 1000 VA capacity provides ample headroom for heavy‑load applications, and the robust construction guarantees long‑term performance in harsh industrial settings. Upgrade your power quality with the SolaHD conditioner – a reliable, certified solution for any high‑performance power system.
  • 120 DB common mode noise attenuation
  • 60 DB transverse mode noise attenuation
  • Galvanic isolation
  • UL/CSA certified (Canada & US)
  • 1000 VA power capacity with multi‑voltage input (110/120/220/240/380/415 VAC)

Specifications

Application
Industrial Automation and Control Equipment Power PLCs, Machine Tools, Robotics, Semiconductor Fabrication Equipment
Brand Name
SolaHD
Frequency Rating
50 HZ
Height
13 IN
Input
110, 120, 220, 240, 380, 415 VAC
Length
7 IN
Mounting
Bracket
Noise Level
35 to 65 dBA
Output Power
110, 120, 220, 240 VAC
Special Features
+/- 3% output voltage regulation, Surge protection tested to ANSI/IEEE C62.41. Class A & B waveform, Harmonic filtering, Galvanic isolation, Noise attenuation 120 dB common mode/60 dB transverse mode
Standard
RoHS Compliant
Style
1
Type
MCR Hardwired Series Power Line Conditioning with Voltage Regulation
Width
9 IN
Package Dimensions (L x W x H)
22.5 IN x 12.8 IN x 11.8 IN
Package Dimensions (L x W x H)
57.15 cm x 32.512 cm x 29.972 cm
Package Weight (Imperial)
68.600 L
Package Weight (Metric)
31.117 kg
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-175-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:750VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage:600, Output Voltage: 120/208/240

63-32-210-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage:600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-210-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1000VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240

63-31-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-625-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:250VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-215-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:1500VA, Input Voltage 120, (6) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240

63-32-220-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage:600, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240

63-23-720-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:2000VA, Input Voltage: 110/120/220/240/380/415, Output Voltage: 110/120/220/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug

63-13-150-6

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US), UL 1012, CSA, Wattage:500VA, Input Voltage 120, (4) NEMA 5-15R Receptacles, (1) NEMA 5-15P Plug
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-150-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:500VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:750VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-175-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:750VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240
Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

63-23-210-8

Features:120 DB Common Mode, 60 DB Transverse Mode Noise Attenuation, Galvanic Isolation, Standard:UL (CANADA AND US) , UL 1012, CSA, ANSI/IEEE C62.41, Wattage:1000VA, Input Voltage: 120/208/240/480, Output Voltage: 120/208/240

Frequently Asked Questions

Does the SolaHD MCR Hardwired Series require maintenance?

No maintenance is required for the SolaHD MCR Hardwired Series.

What is the operating temperature range for the MCR series?

The operating temperature range is -20° to 50°C, with humidity less than 95% non-condensing.

What is the output voltage regulation for 50 Hz MCR units?

For 50 Hz MCR units, the output voltage regulation is ±5% when input voltage is between 80% and 110% of nominal.

What is the operating frequency for model 63-23-710-8?

Model 63-23-710-8 operates at 50 Hz, as it belongs to the MCR Series Group 4.

What are the input and output voltages for model 63-23-710-8?

Model 63-23-710-8 accepts input voltages of 110, 120, 220, 240, 380, 415V and outputs 110, 120, 220, 240V.

What is the recommended minimum load for the unit?

It is recommended that the unit run at a minimum of 40-50% load. The minimum loading is 40%.

What are the dimensions and shipping weight of model 63-23-710-8?

Model 63-23-710-8 has dimensions of 18 in H x 9 in W x 7 in D and a shipping weight of 64 lbs.

What certifications does the MCR Hardwired Series (Group 4) have?

Group 4 MCR units are RoHS Compliant and Listed to UL 1012 and CSA C22.2 No. 107.1.

What is the warranty period for this product?

The product comes with a 10 + 2 year limited warranty.

What certifications does the MCR Hardwired Series (Group 4) have?

Group 4 MCR units are RoHS Compliant and Listed to UL 1012 and CSA C22.2 No. 107.1.

Frequently Asked Questions about SolaHD

What certifications and standards do SolaHD products comply with?

SolaHD power supplies are UL 508 Listed for Industrial Control Equipment and comply with multiple international standards, including UL 60950, CUL/CSA-C22.2 No. 234-M90, and IECEx certifications. Our products meet EMC and Low Voltage Directives, with extensive hazardous location certifications including Class I Zone 2, ATEX, and IECEx, ensuring reliable performance in industrial environments.

What industries and applications are SolaHD products used for?

SolaHD products are used across a wide range of critical industrial applications, including factory automation, process control, machine control, material handling, building automation, and harsh environment installations. Key industries include manufacturing, process industries, semiconductor fabrication, packaging, conveying equipment, instrumentation, and environments requiring UL508 compliance such as water treatment facilities. The products are specifically designed for challenging industrial settings, with certifications for hazardous locations and extreme temperature ranges.

What technical support does SolaHD offer?

SolaHD offers comprehensive technical support through experienced sales representatives available worldwide. Our support includes expert consultation for selecting the right power quality solutions, with award-winning online tools to help customers make precise product selections. Technical support covers the entire range of our industrial power solutions, from service entrance protection to point-of-use equipment, ensuring customers can optimize their facility's power infrastructure.

What are the main product lines offered by SolaHD?

SolaHD offers a comprehensive range of industrial power quality solutions across five primary product lines: Power Supplies, Surge Protection Devices (SPDs), Transformers, Power Conditioning, and Uninterruptible Power Supplies (UPS). Key product series include SDN Power Supplies, STV/STFV Surge Protective Devices, Industrial Control Transformers, MCR Constant Voltage Conditioners, and SDU UPS systems designed for industrial automation, process control, and critical manufacturing environments.

What are the key features of SolaHD products?

SolaHD products offer comprehensive industrial power quality solutions that convert, clean, and maintain electric current throughout manufacturing facilities. Key features include noise and surge protection, voltage regulation, drive protection, and uninterruptible power supplies (UPS). Their product lines cover everything from service entrance to point-of-use, with compact DIN rail mountable options that provide flexible, space-saving power solutions for sensitive industrial equipment like PLCs, networks, and control systems.

What environmental ratings do SolaHD products have?

SolaHD products feature robust environmental ratings including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 classifications, as well as IP66 protection. These ratings ensure comprehensive protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What accessories are available for SolaHD products?

SolaHD offers a comprehensive range of accessories across multiple product lines, including surge protective devices (SPD), tracking filters, power supplies, UPS systems, and DIN rail mountable components. Key accessories include the STV100K Surge Protective Device, STFV Plus Series Tracking Filters, SDN and SCP Series Power Supplies, SDU Series UPS, and various DIN rail filters and converters that can be integrated into industrial control panels and power systems.

How are SolaHD products typically installed?

SolaHD products are typically installed on DIN rail mounting systems in industrial control panels, with multiple installation options including panel/wall mounting brackets. Most products feature easy-to-wire screw terminations, making them suitable for critical industrial applications like factory automation, PLCs, robotics, and computer-based control systems. The products are designed for flexible installation across various industrial environments, with wide operating temperature ranges from -20°C to +50°C and compact, rugged industrial designs.