Contact for Pricing
Overview
- Momentary switching function for precise control.
- Two normally open (NO) AgNi contacts for reliable switching.
- Faston terminal connections (2.8 x 0.8 mm) for easy wiring.
- Protection Class II (protective insulation) for enhanced safety.
- Rated for 16A thermal continuous current (Ith) and 3A AC15 operating current.
Specifications
Utilization Category | AC15 B300 DC13 Q300 |

BZLI
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: W2x46d Labeling Option: No
BZLI5
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
AZOSOI
Switching Function: Momentary Travel: 3 / 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
ETR
Product Group: Contact BlocksContact Type: Screw Connection 2.5 mm? Travel: 6 mmProtection Class: II (protective insulation) Contact Equipment: 1 x NC + 1 x NO
DMR
Color: BlackLabeling Option: NoIllumination: NoProduct Series: Contact blocks DS... Product Group: Contact Blocks
DTI
Switching Function: Momentary Travel: 6 mmContact Type: Cage-Clamp 0.08-2.5 mm? Contact Equipment: 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: No
DTO
Switching Function: Momentary Travel: 6 mmContact Type: Cage-Clamp 0.08-2.5 mm? Contact Equipment: 1 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
BL5
Contact Equipment: LampholderContact Type: Faston Terminal 2.8 x 0.8 mmProtection Class: II (protective insulation) Lambholder: T55KIllumination: Yes Labeling Option: NoFrequently Asked Questions
What are the operating temperature limits for the BZLII5?
The operating temperature is -30°C to 70°C without illumination. It is -30°C to 55°C with incandescent lamps and -30°C to 65°C with LED illumination.
What is the minimum current and voltage for the BZLII5?
The minimum current is 1 mA and the minimum voltage is 5 V.
What type of connections does the BZLII5 use?
The BZLII5 uses flat-plug connectors measuring 2.8 mm x 0.8 mm.
What is the mechanical and electrical lifespan of the BZLII5?
The mechanical lifespan is 1 million switching cycles, and the electrical lifespan at nominal load is also 1 million switching cycles.
What is the contact material used in the BZLII5?
The contact material used is AgNi (Silver Nickel).
What is the rated insulation voltage for AC and DC?
The rated insulation voltage (Ui) is 250 V for AC and 300 V for DC.
What are the rated operating voltages for AC and DC?
The rated operating voltage (Ue) is 240 V for AC and 250 V, 125 V, 60 V, or 24 V for DC.
What is the maximum rated operating current for AC and DC?
The rated operating current (Ie) is 1.5 A for AC and ranges from 0.2 A to 2 A for DC, depending on the voltage.
What is the maximum lamp voltage and power for the BZLII5?
The maximum lamp voltage is 60 V and the maximum lamp power is 1.2 W.