Schlegel Elektrokontakt ATL2 Switching Function: Momentary Travel: 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm…
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Momentary (spring-return) switching with 6 mm travel for precise actuation
- Dual contact configuration: 2 Normally Closed (NC) + 2 Normally Open (NO) contacts in AgNi with gold plating
- Integrated T5.5K lamp holder supports incandescent or LED illumination up to 1.2 W
- Rated for 250 V AC/DC, 6(3) A, with electrical life of 1,000,000 switching cycles
- Faston terminals (2.8 x 0.8 mm) for secure, vibration-resistant wiring
Specifications
Actuation Travel | 6 mm |
Amperage Rating | 3 A AC |
Certifications | CCC, CSA, cURus, ENEC10, VDE, CE, UKCA, UR, DNV |
Connection Type | Faston terminal 2.8 mm x 0.8 mm |
Connection Type | Faston Terminal 2.8 x 0.8 mm |
Contact Material | AgNi |
Contact Type | 2NC / 2NO |
Electrical Life | 1.000.000 operations |
Housing Color | Transparent |
Illuminant | T5.5K Lampenfassung |
Illumination | Yes |
Insulation Voltage | 250 V AC |
Ip Rating | II (Protection Class) |
IP Rating | IP00 |
Material | AgNi |
Mechanical Life | 1.000.000 operations |
Poles | 2 NC + 2 NO |
Positive Opening | per EN 60947-5-1 Annex K |
Product Type | Kontaktgeber |
Rated Current | 6(3) A |
Rated Voltage | 250 V AC/DC |
Series | Kontaktgeber A... |
Size | 6 mm Travel |
Storage Temperature | -50 °C to 85 °C |
Switching Function | Tastfunktion |
Temperature Rating | -30 °C to 70 °C ohne Beleuchtung / -30 °C to 55 °C bei Glühlampenbeleuchtung / -30 °C to 65 °C bei LED-Beleuchtung |
Voltage Rating | 240 V AC |

ATL
Switching Function: Momentary Travel: 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NC + 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
ML
Contact Type: Screw Connection 2X 2.5 Mm?Lambholder: BA9sDegree of Ingress Protection: IP00 Protection Class: II (protective insulation)Illumination: Yes Labeling Option: No
BZLO
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: W2x46d Labeling Option: No
BZLI
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: W2x46d Labeling Option: No
BZLOOK
Switching Function: Momentary Travel: 3 mmContact Type: Screw Connection 2.5 mm? Contact Equipment: 2 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: W2x46d Labeling Option: No
AF2
Switching Function: Maintained Travel: 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
AFL2
Switching Function: Maintained Travel: 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
BZL_439
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Labeling Option: NoFrequently Asked Questions
What is the operating temperature range for the ATL2?
The operating temperature is -30 °C to 70 °C without illumination, -30 °C to 55 °C with incandescent lighting, and -30 °C to 65 °C with LED lighting.
What are the rated operating voltages for the ATL2?
The rated operating voltages are 240 V AC, 250 V DC, 125 V DC, 60 V DC, and 24 V DC according to IEC/EN 60947-5-1.
What is the rated operating current for the ATL2?
The rated operating currents are 3 A AC, 0.2 A DC, 0.4 A DC, 1 A DC, and 2 A DC according to IEC/EN 60947-5-1.
What is the rated insulation voltage of the ATL2?
The rated insulation voltage is 250 V AC and 250 V DC according to IEC/EN 60947-5-1.
What type of socket does the ATL2 use for its light source?
The ATL2 uses a T5,5K lamp socket for its light source.
What is the rated impulse withstand voltage for the ATL2?
The rated impulse withstand voltage for the ATL2 is 2.5 kV.
What is the maximum power for the light source in the ATL2?
The maximum power for the light source is 1.2 W.