Schlegel Elektrokontakt AFL2 Switching Function: Maintained Travel: 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm…
Documents & Media
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 6mm actuation travel with 2NC + 2NO AgNi contacts
- 24V AC/DC LED illumination (max 1.2W) with T5.5K lamp holder
- Faston terminals (2.8 x 0.8mm) for 0.14–1.5mm² wire
- Rated 6A thermal current, 3A at 240V AC15, 1M switching cycles
- Operating temp: -30°C to 65°C (LED), 250V AC/DC rated
Specifications
Actuation Travel | 6 mm |
Amperage Rating | 3 A AC |
Certifications | CCC, CSA, ENEC10, VDE, CE, UKCA, UR, DNV |
Connection Type | Faston terminal 2.8 mm x 0.8 mm |
Contact Material | AgNi |
Contact Type | 2NC / 2NO |
Electrical Life | 1.000.000 operations |
Housing Color | Transparent |
Illuminant | T5.5K Lampenfassung |
Illumination | Yes |
Insulation Voltage | 250 V AC |
IP Rating | IP00 |
Mechanical Life | 1.000.000 operations |
Positive Opening | per EN 60947-5-1 Annex K |
Product Type | Kontaktgeber |
Rated Current | 6(3) A |
Rated Voltage | 250 V AC/DC |
Series | Kontaktgeber A... |
Storage Temperature | -50 °C to 85 °C |
Switching Function | Rastfunktion |
Temperature Rating | -30 °C to 70 °C ohne Beleuchtung / -30 °C to 55 °C bei Glühlampenbeleuchtung / -30 °C to 65 °C bei LED-Beleuchtung |
Voltage Rating | 240 V AC |

BFL5
Switching Function: Maintained Travel: 3 mmContact Type: Faston Terminals 2.8 X 0.8 Mm Contact Equipment: 1 x NC + 1 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
BZL_439
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 2 x NC + 2 x NOContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Labeling Option: No
BFK
Travel: 3 mmContact Type: Screw Connection 2.5 mm?Protection Class: II (protective insulation) Contact Equipment: 1 x NC + 1 x NO
BZOOK
Switching Function: Momentary Travel: 3 mmContact Type: Screw Connection 2.5 mm? Contact Equipment: 2 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
AZ4O
Switching Function: Momentary Travel: 3 / 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 4 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: No Labeling Option: No
AZL4O
Switching Function: Momentary Travel: 3 / 6 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 4 x NCContact Material: AgNi Protection Class: II (protective insulation)Illumination: Yes Lambholder: T55K Labeling Option: No
BZLI_AU
Switching Function: Momentary Travel: 3 mmContact Type: Faston Terminal 2.8 x 0.8 mm Contact Equipment: 1 x NOContact Material: AgNi gold-plated Protection Class: II (protective insulation)Illumination: Yes Lambholder: W2x46d Labeling Option: NoFrequently Asked Questions
What are the operating temperature ranges for the AFL2?
The operating temperature is -30 °C to 70 °C without illumination, -30 °C to 55 °C with incandescent lamps, and -30 °C to 65 °C with LED illumination.
What is the electrical lifespan of the AFL2?
The electrical lifespan of the AFL2 is 1,000,000 switching cycles.
What are the contact types available for the AFL2?
The AFL2 is available with 2 normally closed (2NC) or 2 normally open (2NO) contacts.
What is the rated current and switching capacity of the AFL2?
The rated current is 6(3) A, and the switching capacity is 6 A at 250 V AC/DC.
What is the mechanical lifespan of the AFL2?
The mechanical lifespan of the AFL2 is 1,000,000 switching cycles.
What is the required short-circuit protection device for the AFL2?
The required short-circuit protection device is an SCPD 6 A with characteristic D.
What is the rated impulse withstand voltage for the AFL2?
The rated impulse withstand voltage for the AFL2 is 2.5 kV.
What is the rated insulation voltage for the AFL2?
The rated insulation voltage according to IEC/EN 60947-5-1 is 250 V AC and 250 V DC, or 300 V AC and 300 V DC.
What type of illumination is supported by the AFL2?
The AFL2 supports illumination using a T5,5K lamp socket with a maximum power of 1.2 W and a maximum operating voltage of 60 V.
What is the rated operational voltage for the AFL2?
The rated operational voltage is 240 V AC, 250 V DC, 125 V DC, 60 V DC, and 24 V DC.