Panduit ZDF48-RADA2 - Pre-Configured Industrial Distribution Frame, 26U, mild steel, pre-installed with P08D09M intelligent MI series PDU, (1) ACF05 rack security handle with dual frequency (125 kHZ/13.56 MHz) card reader, (1) ACF20 handle to PDU harness, (1) ACF10 temperature and door sensor; includes fiber tray, patch panels, cable management, and grounding
Panduit

ZDF48-RADA2

UPC: 613056747692


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Panduit ZDF48-RADA2 is a pre-configured 26U industrial distribution frame constructed from mild steel. This robust unit arrives fully equipped with essential components for immediate deployment in industrial environments. It features a pre-installed P08D09M intelligent MI series PDU, providing advanced power distribution and monitoring capabilities. Security is enhanced with an integrated ACF05 rack security handle, which includes a dual-frequency card reader supporting both 125 kHz and 13.56 MHz frequencies for access control. The frame also includes an ACF20 handle to PDU harness for streamlined connectivity and an ACF10 temperature and door sensor to monitor environmental conditions and physical access. Beyond power and security, the ZDF48-RADA2 is designed for comprehensive network infrastructure. It comes complete with a fiber tray for organized fiber optic cable management, patch panels for network termination, and additional cable management accessories to maintain a tidy and efficient setup. Grounding provisions are also included, ensuring electrical safety and system integrity. This all-in-one solution from Panduit (SKU: ZDF48-RADA2) simplifies the deployment of critical network and power infrastructure within industrial settings, offering a pre-assembled and integrated system for efficiency and reliability.
  • 26U Pre-Configured Industrial Distribution Frame
  • Includes P08D09M Intelligent MI Series PDU
  • ACF05 Security Handle with Dual Frequency Card Reader
  • ACF10 Temperature and Door Sensor Included
  • Mild Steel Construction with Fiber Tray, Patch Panels, and Grounding

Specifications

Application
Industrial Automation
Color
Gray
Depth
31.06 In.
Frequency
125 kHz / 13.56 MHz
Material
Mild Steel
Mounting
Wall mount
Mounting Type
Rack-mounted
Series
ZDF48-RADA2
Size
26U
Standard
UL 508A Standard for Industrial Control Panels, cUL Listed per CSA UL Type 4/12. IP55 Rated and CE
Type
Industrial Distribution Frame With Access Control
Width
23.62 In.
Package Dimensions (L x W x H)
64 IN x 42 IN x 85 IN
Package Weight (Imperial)
295 lbs
Pre-Configured Universal Distribution Frame, Mild steel enclosure, 26U, for six industrial switches; pre-installed with front and rear rack angles, fiber tray, (3) 48-port patch panels, (3) 4U DIN mount brackets, (3) maintenance free UPS's, redundant power supplies AC to DC, terminal blocks, wiring for 120 V AC input, cable management, grounding, (6) fiber spools, (2) back panels, (2) ESD ports, cage nuts, labeling for cable routing, strain relief bars

ZDF48-S65

Pre-Configured Universal Distribution Frame, Mild steel enclosure, 26U, for six industrial switches; pre-installed with front and rear rack angles, fiber tray, (3) 48-port patch panels, (3) 4U DIN mount brackets, (3) maintenance free UPS's, redundant power supplies AC to DC, terminal blocks, wiring for 120 V AC input, cable management, grounding, (6) fiber spools, (2) back panels, (2) ESD ports, cage nuts, labeling for cable routing, strain relief bars

How to Install the ZDF48-RA Industrial Distribution Frame

This guide provides step-by-step instructions for installing and setting up the ZDF48-RA Industrial Distribution Frame, including mounting, wiring, and initial configuration.

Estimated time: 1h

Tools needed:

Screwdriver, Drill, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Tak-Ty cable ties

  1. Unpack the IDF enclosure

    Remove the IDF enclosure from its packaging and take out all miscellaneous items, including mounting hardware and installation guides.

  2. Mount the IDF enclosure

    Stand the IDF enclosure upright and secure it to the wall using the six mounting holes on the wall section, ensuring it is level and stable.

  3. Install power outlets

    Remove the outlet box cover, punch out the knockout, pull the power cable through the conduit into the outlet box, and terminate the power and ground according to local IEC code.

  4. Route copper trunk cables

    Pull the Copper-A trunk cable through the conduit into the enclosure, route it up the left side of the rear backplane, and secure it using Tak-Ty and D-rings.

  5. Terminate copper cables

    Bundle the cables in sets of four, feed them through the openings in the patch panel, and terminate them onto the copper jacks according to the installation instructions.

  6. Install switches

    Install the Copper Switch A in the designated RU, connect it to the patch panel, and ensure all connections are secure and properly routed.

  7. Connect power cords

    Attach the power cords for the switches to the UPS, ensuring they are secured with Tak-Ty to prevent movement.

  8. Complete setup

    Follow the specific switch installation instructions to finalize the setup and ensure all components are functioning correctly.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.