Contact for Pricing
Overview
- 24" x 24" 316 stainless steel enclosure for corrosion resistance in harsh environments
- Includes (8) Cat 6 UTP copper patch cords and jacks for copper connectivity
- (2) MM LC fiber patch cords with (6) LC adapters for fiber-optic networking
- DIN rail-mounted copper patching module, strain relief bar, and (10) cable management L rings
- Ground bar, fiber slack spool, and lockable door for secure, organized deployments
Specifications
Application | Industrial Automation |
Color | Gray |
Depth | 11.6 In. |
Material | Stainless Steel Type 316 |
Mounting | Wall mount |
Standard | UL 508A Standard for Industrial Control Panels, UL Type 4/12 or 4X, IP66 Rated, RoHS Compliant |
Type | Pre-Configured Network Zone System Enclosure |
Width | 24 In. |
Package Dimensions (L x W x H) | 44 IN x 44 IN x 17 IN |
Package Weight (Imperial) | 170 lbs |

Z23U-621S
Universal Network Zone System, 24" x 36", 316 stainless steel, for two industrial switches, includes (16) Cat 6A STP copper patch cords and jacks, (4) MM LC fiber uplink patch cords with (6) adaptors and redundant power supplies, battery UPS.
CFPL6S-2GY
The Mini-Com Stainless Steel Faceplate accepts six Mini-Com Modules. The faceplate is double gang and mounts to a NEMA standard double gang opening. The faceplate includes a label pocket for easy identification and is made of impact resistant material to support installations in high traffic areas.
CFP2SY
The Mini-Com Stainless Steel Faceplate accepts two Mini-Com Modules. The faceplate is single gang and mounts to a NEMA standard single gang opening. The faceplate can be identified with an adhesive label and is made of impact resistant material to support installations in high traffic areas.
IAEBHC5E
The IndustrialNet Cat 5e UTP bulkhead RJ45 coupler module with protective cap is ideal in manufacturing environments. The bulkhead provides an IP67 rated seal that provides protection from dust and temporary immersion in water.
IAEBH5ES
The IndustrialNet Cat 5e shielded bulkhead 8-position connector with protective cap is ideal in manufacturing environments. The shielded bulkhead connector features a RJ45 jack. The bulkhead provides an IP67 rated seal that provides protection from dust and temporary immersion in water. It terminates to a 4-pair, 24 AWG, 100 ohm twisted pair cable and does not require a punchdown tool.
PZNDVK
The NEMA 4X rated drain and vent kit mounts externally to NEMA enclosures and allows the enclosure to breathe to reduce the chance of condensation while still maintaining NEMA 4X rating.
FAP6WBUSCZ
The Opticom SC fiber adapter panel is OS2 and is loaded with 6 SC simplex fiber optic adapters. The fiber optic adapters are blue with zirconia split sleeves.Frequently Asked Questions
What is the voltage range for FSD77-10-D?
The FSD77-10-D operates on 24V DC with a range of 20-28V DC.
Is the FSD77-10-D compatible with other Panduit products?
Yes, the FSD77-10-D is compatible with various Panduit wiring ducts and cable management solutions.
What is the EMI protection capability?
The FSD77-10-D includes EMI noise shielding that provides up to 20dB reduction in noise, enhancing performance.
How do I install the FSD77-10-D?
Installation requires user-supplied DIN rail and fasteners, with specific mounting clips for corner wiring duct.
How does the FSD77-10-D improve space optimization?
The FSD77-10-D is designed to maximize space utilization within control panels, allowing for more components in a smaller footprint.
Can I use the FSD77-10-D in harsh environments?
Yes, the FSD77-10-D is designed for harsh environments, ensuring reliable performance under challenging conditions.
What safety precautions should I take?
Always follow recommended safety precautions to prevent harm and ensure a safe working environment.
What maintenance is required for the FSD77-10-D?
Regular inspection and maintenance are recommended to ensure optimal performance, but specific maintenance tasks are not detailed.
What are the temperature operating requirements?
The product is designed to operate within a specified temperature range, but the exact range is not provided in the document.
What is the standard package quantity for the FSD77-10-D?
The standard package quantity for the FSD77-10-D is not explicitly stated in the document.
How to Install the Z22C-6 Network Zone System
Installation guide for mounting and wiring the Z22C-6 Network Zone System enclosure.
Estimated time: 1h
Tools needed:
Latch Tool, Screwdriver (#2 Phillips, 3/16", 2.5mm flathead), 3/8" socket or box wrench, Tools to cut enclosure sidewalls (e.g., Greenlee punch), Drill, Level
Supplies needed:
Mounting feet kit (if applicable), 5/16" bolts (for steel enclosure), 3/8" bolts (for stainless-steel enclosure), #6 AWG Infrastructure ground cable, Fiber-optic trunk cable, LC fiber-optic connectors, Fiber-optic termination tools, Category 6 copper cable, Copper cable termination tools, Power wiring (#14 AWG recommended), Rigid conduit, Silicone rubber sealant (if required for NSF certification)
- Prepare the Enclosure
Open the enclosure door by turning both locks toward each other using the Latch Tool. If reversing the door, remove hinge pins, screws, and hinges. Drill new hole locations on the opposite side, reinstall hinges and screws, then turn the door 180 degrees and mount it to the opposite side. Insert pins to secure the door. Install screws and sealing washers in the original hinge hole locations.
- Install Mounting Feet (Optional)
Turn the enclosure on its side with locks oriented toward the top. Install the Wall Mounting Feet into the back of the enclosure, aligning the threaded studs with the holes. Insert sealing washers into the holes from the outside, with the tapered cone toward the hole. Turn the enclosure upright. Thread nuts onto the mounting foot studs and tighten to 200 in-lbs.
- Mount the Enclosure
Determine the mounting location. If using mounting feet, drill holes 22.5" apart horizontally and 25.56" apart vertically. If mounting directly to the wall without feet, drill holes 22.5" apart horizontally and 22.5" apart vertically. Mount the enclosure securely to the wall using appropriate bolts (5/16" for steel, 3/8" for stainless steel) or Unistrut. If required for NSF certification, seal the perimeter between the enclosure and the back mounting surface with silicone rubber sealant.
- Install Internal Components (if applicable)
For Universal Network Zone Systems, remove wires from terminal blocks and then remove the terminal blocks. Install the customer-supplied switch according to the switch manufacturer's instructions and the supplied Field Wiring Diagram. Install the supplied ground wire to the switch. Do not apply power prior to terminal block removal and switch installation.
- Connect Power and Uplink/Downlink Cables
Refer to the Field Wiring Diagram supplied inside the unit for specific wiring instructions. Connect power entry, uplink entry, and downlink entry cables using appropriate conduit and connectors. Ensure all connections are secure and meet local electrical codes. For customer-supplied switch power input wiring, use #14 AWG recommended wire and connect to the Field-Wiring Terminal.
- Route Patch Cords and Finalize
Route fiber-optic and copper patch cords through the designated management features. Connect the Zone SYS to the uplink using the provided CAT6 copper patch cords or LC fiber patch cords as applicable. Close and secure the enclosure door by turning the locks.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.