Contact for Pricing
Overview
- Monitors UPS switching to battery mode for controlled server shutdown/restart.
- Prevents data loss and system downtime during power failures.
- IP20 touch-proof screw terminals for safe installation.
- Accommodates wire sizes from 12-22 AWG.
- Provides signals for "On Battery," "Low Battery," and "UPS Shutdown" conditions.
Specifications
Package Dimensions (L x W x H) | 3.26 IN x 4.5 IN x 1.69 IN |
Package Weight (Imperial) | 2.2 lbs |

U02N11L
SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail KitFrequently Asked Questions
What is the SmartZone UPS Relay Card's primary function?
The SmartZone UPS Relay Card provides UPS internal status externally or controls peripheral devices based on UPS status using Form-C dry contacts.
What are the key features of the URC005?
Key features include remote monitoring of UPS functions via dry contact relays, providing Normally Open (NO) and Normally Closed (NC) outputs, and hot-swappable capability.
What is the input voltage for the URC005?
The input voltage on the Common Source for the URC005 is 12 VDC at a maximum of 2A.
What is the maximum current consumption?
The total current consumption for all relay outputs combined is a maximum of 2A.
What is the operating temperature range?
The operating temperature range for the URC005 is 0 to 60°C.
What is the storage temperature range?
The storage temperature range for the URC005 is -20°C to 60°C.
What is the operating humidity range?
The operating humidity range is 10% to 95% RH, non-condensing.
What is the storage humidity range?
The storage humidity range is 5% to 95% RH.
What is the maximum operating elevation?
The URC005 can operate at elevations from 0 to 10,000 ft. (0 to 3000 m).
What is the maximum storage elevation?
The URC005 can be stored at elevations from 0 to 30,000 ft. (0 to 9144 m).
How to Install the Panduit UPS System
This guide provides step-by-step instructions for installing the Panduit UPS system, including mounting, wiring, and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Cage nuts, Terminal connectors
- Mount the UPS unit
Install the URMKIT2 rail kit by securing the front side of the rail kit with 3x Phillips Pan Head M5 screws on each rail. Adjust the rail size according to the depth of the rack and then install the rear side of the rail kit with 3x Phillips Pan Head M5 screws on each rail. Tighten all screws to secure the rails.
- Connect the internal battery cartridge
Remove the faceplate of the UPS by pressing both sides until the latches release. Connect the internal battery cartridge connector firmly to ensure a proper connection, then reinstall the faceplate.
- Secure the UPS in the rack
Slide the UPS into the rack on the rail kit. Align the mounting brackets with the screw holes on the rack and secure the UPS with the supplied 4x Phillips Hex Head M5 screws.
- Perform electrical connections
Ensure that all units in the UPS system are properly grounded before power is applied. Connect the UPS system only to an earth-grounded outlet that is easily accessible.
- Verify installation
Use a multimeter to check for hazardous voltages between terminals before powering on the UPS system. Ensure that cover plates on all units are installed before providing power.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.