Contact for Pricing
Overview
- Universal connector compatible with Panduit G5 uPDU chassis
- IEC 60309 3P+N+E 6h 32A plug with IP44 ingress protection
- 3-meter (10-foot) cord length for flexible installation
- Rated for 32A continuous current for high-power applications
- Manufactured in the US by Panduit for reliability and compliance
Specifications
Amperage Rating | 32 A |
Color | Black |
Connection Type | Universal/IEC 60309 3P+N+E 6h |
Connection Type | Universal / IEC 60309 |
Connector | Universal PDU |
Current Rating | 32 A |
Ip Rating | IP44 |
Material | Cord Set |
Plug Type | IEC 60309 3P+N+E 6h 32A (IP44) |
Poles | 3P+N+E |
Series | G5 Panduit Universal PDU (uPDU) |
Series | Panduit G5 uPDU |
Size | 3 meters |
Size | 10 ft (3m) |
Type | uPDU Power Cord |
Package Dimensions (L x W x H) | 19.685 IN x 15.472 IN x 5.315 IN |
Package Weight (Imperial) | 9.92 lbs |

UPDUCRD9
The G5 Panduit Universal PDU (uPDU) cord set features a Universal connector that connects to the uPDU chassis and IEC 60309 2P+E 6h 32A (IP44) facility side plug. The cord set is 10 (3m) in length.Frequently Asked Questions
What is the part number for this cord set?
The Panduit SKU Part No. for this facility side cord set is UPDUCRD1.
What type of plug does the UPDUCRD1 cord set use?
The UPDUCRD1 cord set uses an IEC 60309 3P+N+E 6h 32A (IP44) plug.
What is the length of the UPDUCRD1 cord set?
The UPDUCRD1 cord set has a length of 3 meters (10 feet).
What input voltage does the UPDUCRD1 cord set support?
The UPDUCRD1 cord set supports an input voltage of 400/415 VAC.
What is the input current per phase for UPDUCRD1?
The input current per phase for the UPDUCRD1 cord set is 32 Amps.
What is the input phase configuration for UPDUCRD1?
The UPDUCRD1 cord set is designed for a 3-phase input configuration.
What is the apparent power (kVA) for UPDUCRD1?
The apparent power for UPDUCRD1 is 17.3 kVA in North America and 22.0 kVA in EMEA.
How is UPDUCRD1 identified in the Web GUI?
In the Web GUI, UPDUCRD1 is identified as 30A3WYE (NAM) or 32A3WYE (EMEA).
What safety features does the uPDU include?
The uPDU includes 10kAIC hydraulic magnetic circuit breakers for overload protection and an external chassis ground meeting NEC requirements.
What is the operating temperature range for the uPDU?
The uPDU operates reliably in temperatures from 50°F to 140°F (10°C to 60°C) at full load.
How to Install the Panduit G5 Power Distribution Unit (PDU)
This guide provides step-by-step instructions for installing and configuring the Panduit G5 PDU in a data center rack.
Estimated time: 45m
Tools needed:
Phillips screwdriver, Torx screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Cage nuts, Ground bonding cable
- Install Mounting Hardware
Align and install the mounting buttons with the screw holes on the sides of the PDU. Insert the mounting buttons into the keyhole slots on the PDU mounting bracket in the rack.
- Connect the Ground Bonding Cable
Attach the ground bonding cable to the external ground bonding point located on the chassis of the PDU. Ensure the connection is secure to prevent electric shock.
- Connect the PDU to Power Source
Turn the feed circuit breaker Off. Connect the PDU to an appropriately rated branch circuit and ensure all circuit breakers on the PDU are set to On. Turn the feed circuit breaker On.
- Configure the PDU Input Type
Access the Web interface of the PDU. Navigate to the System Management page and select 'Set Input Cord' under actions. Choose the correct cord type and save the settings.
- Verify Installation
Check the OLED display for the status bar indicating the PDU operating system is loading. Ensure all outlets are powered up and functioning correctly.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.