Authorized Panduit Distributor
Panduit UICMPPK6G24BL - The Mini-Com Ultimate ID Modular Patch Panel Kit includes 24 Cat 6 TG Jack Modules for unshielded applications in 1 RU and mounts to 19 inch and 23 inch racks and cabinets. The panel offers front access and includes label pockets for easy identification (labels are not included). The patch panel is black.

Panduit UICMPPK6G24BL The Mini-Com Ultimate ID Modular Patch Panel Kit includes 24 Cat 6 TG Jack Modules for…

UPC: 074983680856


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit Mini-Com Ultimate ID Modular Patch Panel Kit (SKU: UICMPPK6G24BL) delivers a high-density, front-access solution for unshielded Cat 6 network cabling in 1RU rackmount environments. This 24-port patch panel integrates Cat 6 TG Jack Modules optimized for Gigabit Ethernet and 10GBASE-T applications up to 55 meters, ensuring reliable data transmission in enterprise, data center, and industrial networks. The black, 19-inch and 23-inch compatible design mounts securely to standard racks and cabinets, providing front-panel access for simplified cable management and maintenance. Each module supports T568A and T568B termination standards, with integrated label pockets for clear port identification—labels sold separately. The modular architecture allows for future upgrades or replacements without replacing the entire panel, reducing long-term operational costs. Ideal for structured cabling systems requiring scalability and ease of deployment, this patch panel meets ANSI/TIA-568 and ISO/IEC 11801 standards for Cat 6 performance. The unshielded design reduces weight and cost while maintaining compatibility with common UTP cabling infrastructures. With a compact 1RU form factor, it maximizes space efficiency in dense network installations.
  • 24 Cat 6 TG Jack Modules for unshielded applications
  • 1RU height, mounts to 19-inch and 23-inch racks/cabinets
  • Front-panel access for simplified cable management
  • Integrated label pockets for easy port identification
  • Supports T568A and T568B termination standards

Specifications

Application
NA
Color*
Black
Depth
0.76 In.
Material
CRS
Number Of Ports
24
Patch Panel Style*
Flat
Performance Level*
Category 6
Standard
RoHS Compliant
Type
Patch Panel Kit
Width
19 In.
Package Dimensions (L x W x H)
20 IN x 3.5 IN x 3 IN
Package Weight (Imperial)
1.4 lbs
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What types of modules can be used?

The patch panels accept all Panduit Mini-Com® Modules for UTP, STP, fiber, or A/V applications.

What is the mounting requirement for the patch panels?

The patch panels mount to standard 19 in racks or 23 in racks with optional extender brackets.

What are the available port densities?

The patch panels are available in 24-port and 48-port standard densities.

What is the design benefit of angled patch panels?

Angled patch panels allow cable to flow to each side of the rack, minimizing the need for horizontal cable managers.

What materials are used in the patch panels?

The stamping is made of CRS and the faceplate is made of ABS.

What labeling standards do the panels comply with?

The panels comply with the TIA-606-C labeling standard for cable and port identification.

What is included in the packaging?

The packaging includes pre-installed snap-in faceplates, mounting screws, and a label cover kit.

Are there options for cable management?

Optional strain relief bars are available to help support and manage cables.

Can the patch panels be customized?

The patch panels can be customized based on specific needs, including configurations and labeling.

What are the dimensions of the patch panels?

Dimensions vary, but standard panels are typically 1 RU or 2 RU in height and 19 in wide.

How to Install the UICMPPK6G24BL TX6 PLUS and TX5e UTP Jack Modules

Step-by-step guide for installing and terminating the UICMPPK6G24BL UTP jack modules according to TIA/EIA 568-C guidelines.

Estimated time: 15m

Tools needed:

Wire strippers, Flush cutters

Supplies needed:

UICMPPK6G24BL UTP Jack Module, 22-26 AWG solid or stranded IWC data cable

  1. Prepare the Cable

    Strip the outer jacket of the data cable to expose the inner conductors. Do not pre-arrange conductors. Trim the pair separator and/or ripcord if present.

  2. Terminate Conductors

    Refer to the T568A or T568B wiring diagram. Insert each conductor into the corresponding slot on the jack module. Ensure the conductors are properly seated.

  3. Install Strain Relief

    Place the strain relief collar over the terminated conductors. Ensure it is securely in place to prevent strain on the connections.

  4. Attach Wire Cap

    Secure the wire cap over the terminated conductors and strain relief. This protects the connections and ensures a tidy finish.

  5. Finalize Installation

    Ensure all components are properly seated and secured. The jack module is now ready for use. Refer to the datasheet for specific performance information.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.