Panduit U02N16L-N SteadySine™ On-Line Double Conversion Long Runtime UPS, 2kVA, Lithium,120V, NC
UPC: 613056912694
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 2kVA / 1800W output capacity with pure sine wave for sensitive electronics
- Lithium-ion (LiFePO4) batteries with 8-10 year lifespan and 3-hour recharge to 90%
- On-Line Double Conversion topology with zero transfer time during power failures
- Wide input voltage range (90-150VAC) and ±1% output voltage regulation
- Rack/tower convertible design with rotatable LCD display and multiple communication ports
Specifications
Material | Lithium |
Series | SteadySine |
Voltage Rating | 120 V |
Package Dimensions (L x W x H) | 19.68 IN x 17.32 IN x 3.41 IN |
Package Dimensions (L x W x H) | 49.9872 cm x 43.9928 cm x 8.6614 cm |
Package Weight (Imperial) | 39.2400 L |
Package Weight (Metric) | 17.7993 kg |

U02N11L
SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail KitFrequently Asked Questions
What is the derating for Generator mode on 5-10kVA units?
5-10kVA single-phase UPS units in Generator mode are derated to 75% of the maximum output. They maintain a 50Hz or 60Hz output frequency.
Do 10-20kVA 3-phase units have a Generator mode?
No, 10-20kVA 3-phase UPS units do not have a Generator mode setting. These units always operate with a wider input frequency range with no derating.
How long does a battery self-test last?
All battery tests are preset for a duration of 10 seconds. The frequency of the test is user selectable.
Can multiple UPS units be connected in parallel?
Yes, 10-20kVA 3-phase and 5-10kVA Lithium UPS units can be configured in Parallel mode, allowing two to four units of the same rating to be connected.
What are the requirements for parallel UPS power cables?
For parallel mode, all UPS power cables (main input, bypass input, and output) must be the same type and length to facilitate load sharing and zero crossing alignment.
Which UPS units support a Maintenance Bypass Switch (MBS)?
Maintenance Bypass state is supported on Single-Phase 5-10kVA EU region and 3-Phase 10-20kVA UPS units, requiring an optional MBS accessory.
Are batteries hot-swappable in these UPS units?
Yes, all UPS units support hot swappable battery cartridges, which makes them easy to maintain.
What types of power anomalies do these UPS units protect against?
These UPS units protect against power failures, sags, surges, under-voltages, over-voltages, electrical line noises, frequency variations, switching transients, and harmonic distortion.
What battery types are compatible with these UPS units?
These UPS units support either VRLA (Valve Regulated Lead-acid) or Li-Ion (LiFePO4) batteries as the backup power storage system.
Do these UPS units include a network card for monitoring?
Yes, UPS units are standardly equipped with a network card for remote network monitoring, control, and configuration via a user-friendly web interface.
How to Install the Panduit U02N16L-N 2U UPS Unit in a Four-Post Rack
This guide provides instructions for safely preparing and mounting the Panduit U02N16L-N 2U Uninterruptible Power Supply (UPS) unit and its rail kit into a standard four-post rack.
Estimated time: 45m
Tools needed:
Phillips screwdriver, Lift (if needed for heavy units)
Supplies needed:
URMKIT2 rail kit (included), Phillips Pan Head M5 screws (included with rail kit), M5 cage nuts (included with rail kit)
- Review Safety and Prepare Environment
Carefully read all safety warnings and operating instructions in the manual. Ensure the installation environment meets the specified operating parameters: temperature 0-40°C, humidity 20-90% RH (non-condensing), and altitude below 1000m for no derating. Allow at least two hours for the UPS system to acclimatize if moved from a cold to a warm environment. Do not block ventilation holes or install near water, direct sunlight, heat sources, or in excessive dust. It is recommended to mount the unit near the bottom of the rack due to its weight.
- Install the Front Side of the Rail Kit
Install the front side of the URMKIT2 rail kit into your four-post rack. Use three Phillips Pan Head M5 screws on each rail to secure the front. Do not fully tighten these screws at this stage.
- Adjust and Install the Rear Side of the Rail Kit
Adjust the rail size to match the depth of your rack. Once adjusted, install the rear side of the rail kit using three Phillips Pan Head M5 screws on each rail.
- Secure Rail Kit and Install Cage Nuts
Tighten all 12 Phillips Pan Head M5 screws (6 on each side) to firmly secure both the left and right rails to the rack. Next, install four M5 cage nuts in the front equipment rail: one in each of the first locations below the bottom rail kit screw and one in each of the first locations above the top rail kit screw.
- Mount the UPS Unit into the Rack
With the rail kit securely installed, carefully slide the U02N16L-N UPS unit onto the installed rails. Ensure the unit engages properly with the rails and is fully seated within the rack. The unit is heavy, so use a lift or assistance from another person if necessary.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.