Authorized Panduit Distributor
Panduit U01S11V - SteadySine On-Line Double Conversion UPS, 1kVA, 2U, 120V, VRLA, Single Phase, True On-Line Power Protection
Panduit

U01S11V

UPC: 613056825024


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit U01S11V SteadySine On-Line Double Conversion UPS delivers true online power protection with 1kVA capacity in a compact 2U form factor. Designed for single-phase applications requiring 120V input, this VRLA battery-supported UPS ensures continuous, clean power delivery by converting AC to DC and back to AC, isolating connected equipment from surges, sags, and outages. Ideal for critical industrial, IT, and automation systems where power quality is non-negotiable. The double conversion topology provides zero transfer time, maintaining stable output voltage and frequency regardless of input fluctuations. Compatible with standard 120V single-phase systems, the U01S11V supports hot-swappable VRLA batteries for minimal downtime during maintenance. With a 2U rack-mountable design, it integrates seamlessly into existing infrastructure while offering reliable backup power for sensitive equipment. Backed by Panduit’s engineering expertise, this UPS is built in the US for consistent performance in demanding environments.
  • 1kVA true online double conversion UPS for continuous power protection
  • 2U rack-mountable design with 120V single-phase input/output
  • VRLA battery support for reliable backup power and hot-swappable maintenance
  • Zero transfer time ensures seamless power delivery during outages
  • Compact 2U form factor for space-efficient deployment

Specifications

Poles
Single Phase
Series
SteadySine
Size
2U
Voltage Rating
120V
Package Dimensions (L x W x H)
23.2284 IN x 21.8504 IN x 7.9528 IN
Package Weight (Imperial)
41.58 lbs
SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail Kit

U02N11L

SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail Kit
Uninterruptible Power Supply, Capacity: 1440 VA, 900 Watts, Input Voltage: 115 V +/- 25PCT, Frequency: 50 o 60 Hz +/- 10PCT

S1K1500

Uninterruptible Power Supply, Capacity: 1440 VA, 900 Watts, Input Voltage: 115 V +/- 25PCT, Frequency: 50 o 60 Hz +/- 10PCT
Online Double Conversion Large Format UPS with Isolation Transformer 10 KVA 4210085R

4210085R

Online Double Conversion Large Format UPS with Isolation Transformer 10 KVA 4210085R
Back UPS Pro Gaming UPS Wht

BGM1500

Back UPS Pro Gaming UPS Wht
SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection

U02S11L

SteadyPulse Line Interactive UPS, 1.5kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection
SteadySine On-Line Double Conversion UPS, 5kVA, 6U (3U UPS + 3U EBP), 208/240V, VRLA, Single Phase, True On-Line Power Protection & Rail Kit

U05S11V

SteadySine On-Line Double Conversion UPS, 5kVA, 6U (3U UPS + 3U EBP), 208/240V, VRLA, Single Phase, True On-Line Power Protection & Rail Kit
SteadySine On-Line Double Conversion UPS, 2kVA, 2U, 120V, VRLA, Single Phase, True On-Line Power Protection with Intelligent Network Card & Rail Kit

U02N11V

SteadySine On-Line Double Conversion UPS, 2kVA, 2U, 120V, VRLA, Single Phase, True On-Line Power Protection with Intelligent Network Card & Rail Kit
SteadyPulse Line Interactive UPS, 3kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail Kit

U03N11L

SteadyPulse Line Interactive UPS, 3kVA, 2U, 120V, Single Phase, Lithium-Ion Power Protection with Intelligent Network Card & Rail Kit

How to Install the U01S11V Uninterruptible Power Supply

This guide provides step-by-step instructions for installing the U01S11V Uninterruptible Power Supply, including mounting, wiring, and initial setup.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Cage nuts, Terminal connectors

  1. Prepare the installation area

    Ensure the installation area is clean and free of moisture. Verify that the UPS will be installed in an environment with a temperature range of 0-40°C and humidity of 20-90% RH.

  2. Mount the UPS unit

    Install the URMKIT2 rail kit in a four-post rack. Secure the front and rear sides of the rail kit with 3x Phillips Pan Head M5 screws on each rail. Tighten all screws to secure the rail kit.

  3. Connect the internal battery cartridge

    Remove the faceplate of the UPS by pressing the latches on both sides. Connect the internal battery cartridge securely and reinstall the faceplate, ensuring it snaps into place.

  4. Wire the UPS

    Connect the UPS to an earth-grounded outlet. Ensure that all wiring complies with local electrical codes and that the power source is off before making connections.

  5. Perform initial setup

    Power on the UPS and follow the on-screen instructions to configure the initial settings. Verify that the UPS is functioning correctly using a multimeter to check output voltage.

  6. Calibrate the UPS

    Run a self-test on the UPS to ensure it operates correctly under load. Monitor the performance and check for any error messages on the display.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.