Panduit S8522B - The Net-Access S-Type Cabinet is a 45 RU, 800mm W x 1200mm D cabinet. It features a single hinge perforated front door and a split perforated rear door. It includes side panels, casters and is black.

Panduit S8522B The Net-Access S-Type Cabinet is a 45 RU, 800mm W x 1200mm D cabinet. It features a…

UPC: 074983669820


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit Net-Access S-Type Cabinet (SKU: S8522B) is a 45 RU, 800mm wide x 1200mm deep industrial-grade enclosure designed for secure housing of networking, server, and telecom equipment. This cabinet features a single-hinge perforated front door and a split perforated rear door, both providing 360° airflow for optimal thermal management of sensitive electronics. The welded 12-gauge steel frame supports a static load rating of 2500 lb (1134 kg) when uniformly distributed across the two sets of infinitely adjustable 19-inch rack angles (EIA 310-D tapped holes). The cabinet includes side panels, casters for mobility, and a large gland plate in the top for clean cable routing of pre-terminated cables or patch panels. Key specifications include 16 or 14-gauge steel doors, sides, and cover with RAL 9005 black textured low-gloss polyester powder paint finish. The rear doors feature a 3-point, low-profile locking swing handle with two keys included for controlled access. The open bottom design includes integral bolt-down brackets for permanent installation, while the adjustable rack angles allow flexible positioning of equipment from front to rear. Twenty 10-32 screws are included for assembly. Compatible with Panduit’s Net Series accessories such as rack angles, caster kits, leveler kits, joining kits, tool-less blanking panels, vertical tie-down cable managers, and tool-less shelves. The cabinet meets UL 2416 load testing requirements (tested at 4x rated load) and is ideal for data centers, server rooms, network closets, and industrial control environments requiring secure, ventilated, and mobile equipment housing. Contact Panduit Customer Service for alternative finishes beyond the standard black textured powder coat.
  • 45 RU capacity with 800mm W x 1200mm D dimensions for high-density equipment housing
  • Perforated front and split rear doors for 360° ventilation and easy access
  • Static load rating of 2500 lb (1134 kg) with infinitely adjustable rack angles
  • Welded 12-gauge steel frame with RAL 9005 black textured powder coat finish
  • Includes side panels, casters, gland plate, and 20x 10-32 screws

Specifications

Application
NA
Color
Black
Depth
48 In.
Finish
Powder-coated
Material
Steel
Rack Spaces*
45
Series
Net-Access S-Type
Size
45 RU, 800mm W x 1200mm D
Standard
EIA-310-E, TIA/EIA-942, UL Listed 2416, RoHS Compliant
Type
S-Type Cabinet
Width
31.4 In.
Package Dimensions (L x W x H)
54 IN x 35 IN x 95 IN
Package Weight (Imperial)
447 lbs
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the static load rating of the cabinet?

The static load rating is 3000 lbs. for the cabinet.

What is the rolling load rating of the cabinet?

The rolling load rating is 2500 lbs. for the cabinet.

What is the installation time reduction with the leveling feet?

The innovative leveling feet design reduces installation time by up to 80%.

What safety features are included in the cabinet?

The entire cabinet is fully electrically bonded, requiring no grounding whips for safety.

What are the cabinet width options available?

Cabinet widths available are 600mm, 700mm, and 800mm.

What heights are available for the cabinets?

Cabinet heights available are 42RU, 45RU, and 48RU.

Are the cabinets compatible with other Panduit products?

Yes, the cabinets are compatible with various Panduit product lines including FiberRunner®.

What are the color options for the cabinets?

The cabinets are available in black and white color options.

What is the benefit of the integral cabinet air seal?

The integral cabinet air seal improves thermal management and reduces cooling energy consumption.

How can I improve cable management in the cabinet?

Use modular snap-in fingers that align with rack spaces for cable management.

How to Install the S8522B NET-ACCESS S-Type Server Cabinet

Installation guide for mounting and securing the S8522B NET-ACCESS S-Type Server Cabinet.

Estimated time: 1h

Tools needed:

Phillips screwdriver, Flatblade screwdriver, 22mm socket wrench, 15mm socket wrench, 13mm socket wrench, 8mm socket wrench, 48” level, 7mm socket wrench, T30 Torx bit, T25 Torx bit, 6mm Allen key, 2.5mm Allen key, Wire cutter

Supplies needed:

Mounting screws, Terminal connectors, M14 Hex Nuts, M10 Hex Head Screws, M6 Torx Screws, M5 Torx Screws, M10 threaded rod, Grounding Lug, Grounding Bar, M5 bonding screws, Plastic Washer, Latch Plugs, Foam seals, M10x20mm Bolts

  1. Remove Packaging Material

    Remove all stretchwrap and protective cardboard from the outside of the cabinet. Remove all shipping brackets and hold-down brackets. Use at least two persons to carefully lift and remove the cabinet from the pallet.

  2. Level the Cabinet

    Ensure that all four leveling legs are fully retracted. Slide the cabinet into its final position. Lower the leveling legs until the cabinet weight is fully supported by them. Adjust the leveling legs so the cabinet is level front-to-back and side-to-side. When ganging multiple cabinets, ensure adjacent cabinets are adjusted to the same height.

  3. Secure the Cabinet to the Floor (Optional)

    Ensure that all four leveling legs are fully retracted. If desired, secure the 'Shipping Hold Down Brackets' at the front and rear of the cabinet to the floor using M10 Hex Head Screws. Refer to the 'Floor Mounting View' for specific dimensions. WARNING: Mount the cabinet to the floor before installing equipment to prevent tipping.

  4. Gang Cabinets (Optional)

    Ensure cabinets are level. Secure the front ganging brackets to the cabinets at the two front locations using M6 Torx Screws. Secure the rear ganging brackets to the cabinets at the two rear locations using M5 Torx Screws. WARNING: Ganging provides limited stability; proper leveling or floor mounting is still required.

  5. Ground the Cabinet

    Attach a Grounding Lug or Grounding Bar to the Common Bonding Network (CBN) at one of the six indicated locations. Remove factory-installed masking tape to expose an unpainted surface. Fasten the grounding terminal to the cabinet frame using two M5 bonding screws, torqued to 5.1 N-m (45 in-lb). DANGER: Each cabinet must be connected to the CBN.

  6. Adjust Equipment Rails

    Loosen the M10 Hex Head Screws at the top and bottom of the rear equipment rail. Adjust the rail to the desired position and tighten the screws to 30.0 +/- 5.0 N-m (22.1 +/- 3.7 Ft-lbs). WARNING: Remove all equipment from the rails before adjusting spacing.

  7. Install Cable Management Fingers (Optional)

    Insert the tabs of the Cable Management Finger into the mounting slots of the cabinet post. Slide the Cable Management Finger inward to lock it into place.

  8. Install Top of Cabinet Cable Manager (Optional)

    Disassemble front fascia assemblies. Remove screws from the Cable Manager base. Install vertical walls onto the base using M5 Torx screws. Attach the front and rear fascias to the vertical walls using M5 Torx screws. Re-install screws to secure the assembly to the frame.

  9. Install Front and Rear Floor Seals (Vertical Exhaust Duct ONLY)

    Install the Floor Seal to the front or rear of the cabinet frame using two M10x20mm Bolts. Ensure the flange on the floor seal faces outward away from the cabinet.

  10. Install Cabinet Sealing

    Install six latch plugs (three upper, three lower) into the door latch cut-outs on the front side of the cabinet. Install two foam seals to the upper and lower frame, pressing them against the Equipment Rails behind the latch plugs.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.