Panduit PFR6X04WH-CG - The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), White jacket. Packaged 1000ft/305m on a reel
Panduit

PFR6X04WH-CG

UPC: 074983639595


Documents & Media
BrochureInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Minimum Qty: 9000

Multiplier: 1000

*Contact for lower quantities*

Overview

The Panduit TX6A Cat 6A F/UTP Riser copper cable (SKU: PFR6X04WH-CG) is engineered for reliable data transmission in riser applications. This cable features 23 AWG solid copper conductors, each insulated with High-Density Polyethylene (HDPE) for robust performance. The conductors are twisted into pairs and separated by a central cross divider, minimizing crosstalk and ensuring signal integrity. An overall metallic shield provides enhanced protection against electromagnetic interference (EMI) and radio frequency interference (RFI). The cable jacket is constructed from flame-retardant PVC (CMR rated), making it suitable for use in vertical pathways between floors. Supplied in a convenient 1000ft (305m) reel, this white jacketed cable meets the demanding requirements for Category 6A performance, supporting data rates up to 10 Gigabit Ethernet. Its construction is designed for dependable network infrastructure in commercial and industrial environments where signal quality and safety are paramount. Manufactured in the USA.
  • 23 AWG solid copper conductors for reliable data transmission
  • HDPE insulation with cross divider to minimize crosstalk
  • Overall metallic shield for EMI/RFI protection
  • Flame retardant PVC (CMR) jacket for riser applications
  • 1000ft (305m) reel, white jacket, manufactured in the USA

Specifications

Color
White
Conductor Material
Copper
Construction
F/UTP
Flammabiity Rating
CMR
Installation Temperature
32°F to 122°F (0°C to 50°C)
Installation Temperature
32 F to 122 F (0 C to 50 C)
Length
1000 FT
Material
23 AWG Copper Conductors with HDPE Insulation, Flame Retardant PVC (CMR)
No. of Pairs
4
Number Of Conductors
4
Outside Diameter
NA In.
Packaging Type
Reel
Series
TX6A Cat 6A
Size
23 AWG
Temperature Rating
NA F
Type
Bulk Copper Cable
Voltage Rating
NA V
Weight
42.9/1000 ft. lb
Package Dimensions (L x W x H)
44 IN x 44 IN x 44 IN
Package Weight (Imperial)
1157.76 lbs
Shielded copper cable, category 5e F/UTP, plenum (CMP), conductors are 24 AWG construction with FEP insulation, twisted in pairs, surrounded by an overall polyester aluminum foil with stranded copper drain wire and protected by a low smoke flame-retardant PVC jacket, white.

PFP5504WH-UY

Shielded copper cable, category 5e F/UTP, plenum (CMP), conductors are 24 AWG construction with FEP insulation, twisted in pairs, surrounded by an overall polyester aluminum foil with stranded copper drain wire and protected by a low smoke flame-retardant PVC jacket, white.
Rigid copper bar 1750mm 32x5 solid

45103205

Rigid copper bar 1750mm 32x5 solid
Type BTC - Copper Single-Conductor, One-Hole Mount (Offset-Tang), Conductor Range 6 Str-14 AWG, Length 1-9/64, Width 3/8 Inch, Height 11/16 Inch, 13/64 Bolt Inch Hole

BTC0614

Type BTC - Copper Single-Conductor, One-Hole Mount (Offset-Tang), Conductor Range 6 Str-14 AWG, Length 1-9/64, Width 3/8 Inch, Height 11/16 Inch, 13/64 Bolt Inch Hole
The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Black jacket. Packaged 1000ft/305m on a reel

PFR6X04BL-CG

The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Black jacket. Packaged 1000ft/305m on a reel
The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Green jacket. Packaged 1000ft/305m on a reel

PFR6X04GR-CG

The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Green jacket. Packaged 1000ft/305m on a reel
The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Gray jacket. Packaged 1000ft/305m on a reel

PFR6X04IG-CG

The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Gray jacket. Packaged 1000ft/305m on a reel
The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Red jacket. Packaged 1000ft/305m on a reel

PFR6X04RD-CG

The TX6A Cat 6A F/UTP Riser copper cable is constructed of 23 AWG copper conductors with HDPE insulation. The copper conductors are twisted in pairs, separated by a cross divider and covered by an overall metallic shield and a flame retardant PVC (CMR), Red jacket. Packaged 1000ft/305m on a reel
Category 7 low smoke, halogen free, fire retardant (LSHF-FR), 4-pair S/FTP shielded marine copper cable. Stranded copper conductors are 4 x 2/0.27mm+2+. Conductors are twisted in pairs, each individual twisted pair is surrounded by a foil, covered with an overall braided shield and is protected by an oil and fuel resistant, low smoke, halogen free, and fire retardant jacket.

PSM7004IG-KEM

Category 7 low smoke, halogen free, fire retardant (LSHF-FR), 4-pair S/FTP shielded marine copper cable. Stranded copper conductors are 4 x 2/0.27mm+2+. Conductors are twisted in pairs, each individual twisted pair is surrounded by a foil, covered with an overall braided shield and is protected by an oil and fuel resistant, low smoke, halogen free, and fire retardant jacket.

Frequently Asked Questions

How many mating cycles are the connectors rated for?

The connectors are rated for 2500 mating cycles, ensuring long-lasting performance.

What is the maximum operating temperature for the connectors?

The connectors are rated for a maximum operating temperature of 75º C.

What is the warranty period for the Mini-Com Solution?

The Mini-Com Solution comes with a 25-year system warranty when used end-to-end.

What is the smallest diameter for Category 6A patch cords?

The smallest diameter for Category 6A patch cords is 0.185 inches (4.7mm).

What is the rated bandwidth for Category 6 cable?

Category 6 cable has a rated bandwidth of 550 MHz.

What types of applications does the copper cabling support?

The copper cabling supports applications such as Power over Ethernet, wireless connectivity, intelligent lighting, security cameras, and audio/visual systems.

What is the installation method for the Mini-Com jacks?

The Mini-Com jacks feature tool-less termination, which maintains conductor twist for reliable performance.

How many times can the Mini-Com jacks be reterminated?

The Mini-Com jacks can be reterminated up to 20 times.

What is the compatibility of the NetKey jack modules?

NetKey jack modules are designed for compatibility with any keystone opening.

What safety features do the connectors have?

The connectors feature integrated arc suppression technology for enhanced safety.

How to Install the TX6A™ 10Gig™ Copper Cabling System

This guide provides step-by-step instructions for installing and testing the TX6A™ 10Gig™ Copper Cabling System to ensure optimal performance and compliance with industry standards.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter, Fluke DTX-1800 Series Cable Analyzer

Supplies needed:

Mounting screws, Terminal connectors, Patch cords, RJ45 to RJ45 Couplers

  1. Mount the cabling system

    Secure the TX6A™ components, including jack modules and patch panels, to the designated mounting location using the provided mounting screws. Ensure all components are level and firmly attached.

  2. Connect the cabling

    Use terminal connectors to connect the TX6A™ cables to the jack modules and patch panels. Ensure that all connections are tight and properly aligned according to T568A or T568B standards.

  3. Perform channel testing

    Using the Fluke DTX-1800 Series Cable Analyzer, verify that the installed cabling meets the performance requirements. Follow the setup instructions to select the appropriate test limits and perform the tests. Save all test results for warranty submission.

  4. Troubleshoot any issues

    If any channels fail the tests, troubleshoot the connections and cabling. Use the Fluke HDTDX analyzer for detailed diagnostics. Ensure all connections are secure and retest until all channels pass.

  5. Submit warranty documentation

    Compile the electronic channel test reports along with any required warranty paperwork and submit them to the Panduit Warranty Department to obtain the system warranty.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.