Authorized Panduit Distributor
Panduit P42D04G - The Panduit™ G6 Monitored Input PDU features (30) C13 and (12) C19 outlets. It is a 32 amp, 400 V, three phase PDU with an IEC 60309 3P+N+E 6h 32A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.
Panduit

P42D04G

UPC: 613056887350


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsVideo ClipUser ManualOwners Manual

Contact for Pricing

Overview

The Panduit™ G6 Monitored Input PDU (SKU: P42D04G) delivers high-capacity power distribution for mission-critical IT environments. This unit includes (30) C13 outlets and (12) C19 outlets, providing flexible connectivity for a wide range of equipment. Designed for three-phase power systems, it operates at a 32 amp current rating and 400 V voltage, ensuring robust performance under demanding loads. The PDU features an IEC 60309 3P+N+E 6h 32A (IP44) input plug with a 10-foot (3m) power cord, delivering secure and reliable power delivery while maintaining ingress protection against environmental contaminants. Its black chassis is engineered for standard 1U rack mounting, optimizing space efficiency in data centers and server rooms. Equipped with monitored input capabilities, this PDU enables real-time power tracking at the outlet level, supporting precise capacity planning, energy management, and operational efficiency. The unit’s compliance with industry standards and durable construction ensures dependable power distribution in high-performance computing, telecommunications, and enterprise infrastructure applications.
  • 30 x C13 outlets
  • 12 x C19 outlets
  • 32 Amp current rating
  • 400 Volt operation
  • Three-phase power support
  • IEC 60309 3P+N+E 6h 32A (IP44) input plug
  • 10 foot (3m) power cord
  • Monitored input functionality

Specifications

Package Dimensions (L x W x H)
78 IN x 8.2 IN x 4.6 IN
Package Dimensions (L x W x H)
198.12 cm x 20.828 cm x 11.684 cm
Package Weight (Imperial)
23.9000 L
Package Weight (Metric)
10.8410 kg
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!

CUSTOMDIN

DIN rail is a universal mounting option for electrical and industrial control products such as circuit breakers electrical supplies terminal blocks and more. The rail system is used to stabilize a wide variety of devices and products. Ordering pre-cut DIN rail helps increase productivity and decrease jobsite clutter. On-site Flexibility Streamline custom cuts DIN rail to any length so it is ready to use when it arrives on the jobsite. Additionally DIN rail can be easily removed if relocation is necessary. Features of Custom DIN Rail from Streamline - All cut DIN rail from Streamline is galvanized steel made to eliminate rusting. Streamline ensures that all custom DIN rail orders are: De-burred Custom Length Any quantity 1-1000+ Quick turnaround (typically 2 weeks or less from receipt of order) This mechanical support structure is a must for all electrical parts solutions big or small. DIN rail allows for mounting hardware easily and quickly. These durable and versatile rails make the perfect solution for all mounting applications. Save space time and money with these cost-effective mounting solutions. Order your custom cut DIN rail today!
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What are the specifications of the P42D04G PDU?

The P42D04G is a G6 Monitored Input PDU with (32) C13 and (6) C19 outlets. It operates at 30 amp, 208 V, single phase, and includes a 10 foot power cord with a NEMA L6-30P input plug.

What types of outlets does the P42D04G PDU have?

The P42D04G PDU features a strategic mix of (32) C13 and (6) C19 outlets, offering device compatibility and configuration flexibility.

What is the length of the power cord for P42D04G?

The P42D04G PDU comes with a 10 foot (3m) power cord.

What type of input plug does the P42D04G use?

The P42D04G PDU uses a NEMA L6-30P input plug.

What monitoring features does the P42D04G PDU offer?

The P42D04G provides intelligent input level power monitoring, environmental monitoring, and cabinet security monitoring. It also supports SNMP compatibility for power data.

What is the maximum operating temperature for this PDU?

The PDU is built with premium components to withstand high-temperature environments, operating reliably at full load up to 140°F (60°C).

Does the P42D04G PDU have a hot-swappable controller?

Yes, the P42D04G PDU features a hot-swappable controller with a large OLED display. This allows for removal or reorientation without affecting outlet status.

How is the PDU mounted in a rack?

The PDU supports tool-less mounting. It can be effortlessly mounted into a rack using a convenient button slot, simplifying setup.

Can the PDU monitor environmental conditions?

Yes, the PDU supports environmental monitoring to protect IT assets from threats. It is compatible with plug-and-play accessories like temperature and humidity sensors.

What is the warranty for Panduit PDUs?

Panduit PDUs come with a 3-Year standard warranty, with an option for a 5-Year extended warranty.

How to Install and Configure a Panduit G6 PDU

This guide provides step-by-step instructions for qualified personnel to install and initially configure a Panduit G6 Power Distribution Unit (PDU) in a datacenter rack, covering mounting, grounding, wiring, and initial web interface setup.

Estimated time: 1h

Tools needed:

Phillips screwdriver, Torx screwdriver, USB Drive

Supplies needed:

Mounting hardware (buttons/screws), Tie wraps, Ground bonding cable or kit, Input power cord (for Universal Input PDUs)

  1. Mount the PDU in the Rack

    Align and install the mounting buttons into the screw holes on the appropriate side of the PDU (either opposite the outlets for center-facing, or on the sides for back/front-facing). Then, install the PDU by inserting the mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. Ensure the PDU is securely attached. Use only the hardware provided for installation. For dual-sided models, mount on its side with outlets facing the back of the rack.

  2. Connect the Ground Bonding Cable

    Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building, or to the rack's grounding strip/bus bar. This is essential for safety and to reduce the risk of electric shock due to high leakage currents. Ensure a reliable grounded (earthed) connection before connecting to AC power. Refer to the document for minimum bonding conductor requirements based on current rating.

  3. Attach the Input Cord (Universal Input PDUs only)

    If installing a Universal Input PDU, open the input cord connector latches on the PDU. Insert the appropriate input cord plug into the connector, then close the latches to securely lock the input cord. Ensure the input cord has sufficient length to reach the power source without obstruction.

  4. Configure Universal Input PDU Type (Web Interface)

    Access the PDU's Web interface (refer to the User Manual for connection instructions). Navigate to the 'System Management' page under settings. Select 'Set Input Cord' under actions, then choose the correct cord type from the pull-down menu based on your facility side plug and region. Select 'Save' and allow the PDU to reset. WARNING: Selecting the incorrect input cord type may lead to incorrect metering and power rating display.

  5. Connect the PDU to a Power Source

    Before connecting, turn the feed circuit breaker OFF at the power source. Ensure all circuit breakers on the PDU are set to the ON position. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit with overcurrent protection, located near and easily accessible to the equipment. Refer to the label on the PDU for input ratings. Verify that connected devices are compatible with the line voltage supplying the PDU to prevent severe equipment damage. Once connected, turn the feed circuit breaker ON. The OLED screen will display a status bar during boot-up, then the Main Menu.

  6. Secure Power Cords (Optional)

    For connected power cords, utilize the integrated cord retention feature on most C13 and C19 outlets. Plug in the power cord, then use the provided tie wraps. Slide the tie wrap end into the notch next to the outlet, wrap it around the cord, and secure it to prevent accidental disconnects. Optional locking power cords can also be used for enhanced security.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.