Panduit P36F12G - The Panduit™ G6 Monitored Per Outlet PDU features (30) C13 and (6) C19 outlets. It is a 16 amp, 400 V, three phase PDU with an IEC 60309 3P+N+E 6h 16A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.

Panduit P36F12G The Panduit™ G6 Monitored Per Outlet PDU features (30) C13 and (6) C19 outlets. It is a…

UPC: 613056888579


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsVideo ClipUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit™ G6 Monitored Per Outlet PDU (SKU: P36F12G) delivers granular power monitoring and distribution for critical infrastructure environments. This three-phase unit supports 30 IEC C13 outlets and 6 IEC C19 outlets, providing flexible power delivery for servers, networking equipment, and high-density computing applications. Per-outlet monitoring enables precise tracking of power consumption, current draw, and energy usage at each connected device. This data supports capacity planning, load balancing, and proactive identification of potential power issues before they impact operations. Designed for vertical or horizontal mounting in 0U, 1U, or 2U configurations, the G6 series optimizes space utilization while maintaining high power density. The black finish provides a professional aesthetic compatible with standard server rack environments. With its combination of monitoring capabilities, robust construction, and versatile outlet configuration, the P36F12G is ideal for modern data centers requiring efficient power management and operational visibility.
  • 30 IEC C13 outlets and 6 IEC C19 outlets for versatile equipment compatibility
  • 16 amp, 400V three-phase power with IEC 60309 3P+N+E 6h 16A (IP44) input
  • Per-outlet monitoring for real-time power consumption and current draw tracking
  • 10-foot (3m) power cord with secure IEC 60309 input plug for reliable installations
  • Monitored per outlet for granular power management and efficiency.

Specifications

Color
Black
Connection Type
IEC 60309 3P+N+E 6h
Current Rating
16 A
Ip Rating
IP44
Poles
3P+N+E
Series
G6 Monitored Per Outlet PDU
Voltage Rating
400 V
Package Dimensions (L x W x H)
78 IN x 8.2 IN x 4.6 IN
Package Dimensions (L x W x H)
198.12 cm x 20.828 cm x 11.684 cm
Package Weight (Imperial)
17.2000 L
Package Weight (Metric)
7.8019 kg
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

Frequently Asked Questions

What is the amperage rating of this Panduit PDU?

The Panduit G6 Monitored Per Outlet PDU has a 16 amp rating.

How many C13 outlets does the P36F12G have?

The Panduit G6 Monitored Per Outlet PDU features 30 C13 outlets.

What type of input plug does this PDU use?

This PDU uses an IEC 60309 3P+N+E 6h 16A (IP44) input plug.

What is the voltage of the Panduit P36F12G?

The Panduit G6 Monitored Per Outlet PDU operates at 400 V.

Does this PDU support three-phase power?

Yes, the Panduit G6 Monitored Per Outlet PDU is a three-phase unit.

What is the length of the power cord?

The power cord for this PDU is 10 feet (3 meters) long.

How many C19 outlets are included?

The Panduit G6 Monitored Per Outlet PDU includes 6 C19 outlets.

How to Install and Configure a Panduit G6 PDU

This guide provides step-by-step instructions for installing Panduit G6 Metered, Switched, and Metered & Switched Power Distribution Units into a datacenter rack, including physical mounting, power connections, and initial configuration.

Tools needed:

Phillips screwdriver, Torx screwdriver, USB Drive

Supplies needed:

Tie wraps, Ground bonding cable (if required), Input cord plug (for Universal Input PDUs)

  1. Mount the PDU to the Rack

    Use only the hardware provided to install the PDU. Determine the desired mounting orientation (outlets facing center, back, or front of the rack). Align and install the mounting buttons with the appropriate screw holes on the PDU (either on the face opposite the outlets or on the sides). Install the PDU by inserting the mounting buttons into the keyhole slots on the PDU mounting bracket in the rack. Ensure the PDU is securely attached.

  2. Attach the Input Cord to Universal Input PDUs (if applicable)

    This step applies only to Universal Input PDUs. Open the input cord connector latches on the PDU. Insert the facility-side input cord plug into the universal input connector. Close the input cord connector latches on the PDU to securely lock the input cord into the connector.

  3. Ground the PDU

    Ensure a reliable grounded (earthed) connection before connecting power distribution products to AC power to reduce the risk of electric shock due to high leakage currents. For permanently connected PDUs, installation must be performed by a licensed electrician. Locate the external ground bonding point on the PDU chassis (typically on the surface with outlets, or with circuit breakers for dual-sided models). Connect a ground bonding cable from this point to a grounding strip, grounding bus bar, or a known earthed reference terminal in the building. Ensure the bonding conductor meets minimum requirements (e.g., 12 AWG for up to 32A, 8 AWG for up to 63A).

  4. Connect the PDU to a Power Source

    Always follow local and national codes. Connect only to a circuit providing branch circuit overcurrent protection of appropriate current rating. Ensure devices connected to the PDU are capable of operation from the same line voltage. Turn the feed circuit breaker for the power source to the "Off" position. Verify that all circuit breakers on the PDU are set to the "On" position. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) branch circuit electrical outlet that is near the equipment and easily accessible. Turn the feed circuit breaker for the power source to the "On" position. Observe the OLED screen (if present); it will display a status bar during loading, then the Main Menu. Switched and Monitored & Switched PDUs will show a light for each outlet as it powers up.

  5. Configure Universal Input PDU Input Type via Web Interface (if applicable)

    This step applies only to Universal Input PDUs. If the incorrect input cord is selected, the PDU may meter data incorrectly and show an incorrect power rating. Connect to the PDU's Web interface (refer to the User Manual for connection instructions). Navigate to the "System Management" page under "Settings". Select "Set Input Cord" under "Actions". From the "Cord Type Pull Down" menu, select the correct cord type corresponding to your facility-side input cord. Select "Save"; the PDU will reset to apply the new configuration.

  6. Secure Power Cords (Optional)

    For C13 and C19 outlets with integrated cord retention, plug in the power cord. Using the provided tie wraps, slide one end into the notch on the PDU next to the desired outlet and wrap it around the power cord. Secure the tie wrap to prevent accidental disconnects.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.