Panduit P36B43M - This Panduit™ G5 Basic PDU features (30) C13 and (6) C19 outlets. It is a 63 amp, 230 V, single phase PDU with an IEC 60309 2P+E 6h 63A (IP44) input plug and a 10 foot (3m) power cord. The PDU is black.

Panduit P36B43M This Panduit™ G5 Basic PDU features (30) C13 and (6) C19 outlets. It is a 63 amp, 230 V…

UPC: 613056264649


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsUser ManualOwners Manual

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit™ G5 Basic PDU (SKU: P36B43M) is a high-capacity power distribution unit engineered for mission-critical IT and industrial environments. This single-phase PDU delivers 63 amps at 230 volts, providing robust power delivery for dense equipment racks, server rooms, and industrial control panels. The unit features a comprehensive outlet configuration with thirty IEC C13 outlets and six IEC C19 outlets, ensuring compatibility with a wide range of devices including servers, network switches, and high-power industrial equipment. The integrated IEC 60309 2P+E 6h 63A (IP44) input plug ensures secure, compliant power connection in demanding settings, while the 10-foot (3-meter) power cord offers installation flexibility. Housed in a durable black enclosure, the P36B43M adheres to Panduit’s quality standards for reliable, long-term performance. The PDU’s IEC C13 outlets support standard IT equipment such as servers, routers, and monitors, while the six IEC C19 outlets accommodate high-power devices like PDUs, UPS systems, and industrial machinery. The 63A rating allows for high-density power distribution, supporting multiple high-wattage devices without overloading. Designed for seamless integration, the P36B43M meets stringent performance and safety requirements for mission-critical power distribution.
  • 63 amp, 230V single-phase power distribution
  • 30 IEC C13 outlets and 6 IEC C19 outlets for versatile equipment compatibility
  • IEC 60309 2P+E 6h 63A (IP44) input plug for secure industrial connections
  • 10-foot (3m) power cord for flexible installation
  • Durable black enclosure for industrial environments

Specifications

Frequency Rating, Maximum
230 V
Frequency Rating, Minimum
230 V
Material
Metal
Mounting
Vertical
Phase
1
Standard
CE, UKCA, ROHS, REACH, China ROHS
Type
PDU
Width
2 in
Width
50.8 mm
Package Dimensions (L x W x H)
68 IN x 8 IN x 5 IN
Package Dimensions (L x W x H)
172.72 cm x 20.32 cm x 12.7 cm
Package Weight (Imperial)
19.0000 L
Package Weight (Metric)
8.6184 kg
5-port Ethernet Switch

SDI-550

5-port Ethernet Switch
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
24U 21.34W 31.5D CABINET BLK

REFK1904231BK1

24U 21.34W 31.5D CABINET BLK
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Symmetrical DIN rail 2m 35x15x1,5 steel z-b

50000043

Symmetrical DIN rail 2m 35x15x1,5 steel z-b
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.

CPP24FMWBLY

The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

UTP6AL1MBU

The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

Frequently Asked Questions

What is the amperage rating of this Panduit PDU?

This Panduit G5 Basic PDU has a 63 amp rating.

What type of outlets does the P36B43M feature?

The P36B43M features thirty C13 outlets and six C19 outlets.

What is the voltage of this Panduit power distribution unit?

This Panduit G5 Basic PDU operates at 230 volts.

What kind of input plug does the P36B43M use?

The P36B43M uses an IEC 60309 2P+E 6h 63A (IP44) input plug.

What is the length of the power cord on this PDU?

The power cord for this Panduit PDU is 10 feet (3 meters) long.

How to Install and Configure a Panduit G5 PDU

This guide provides step-by-step instructions for installing and initially configuring a Panduit G5 Power Distribution Unit (PDU) in a datacenter rack, covering mounting, grounding, power connection, and universal input setup.

Estimated time: 1h

Tools needed:

Phillips screwdriver, Torx screwdriver, USB Drive

Supplies needed:

Mounting buttons (for vertical PDU installation), Cage nuts (for 1U/2U PDU installation), Tie wraps (for power cord retention), Ground bonding cable

  1. Mount the PDU in the Rack

    Secure the PDU to the datacenter rack using the appropriate mounting hardware for its form factor (vertical, 1U, or 2U). For vertical PDUs, install mounting buttons onto the PDU and then insert them into the keyhole slots on the rack's PDU mounting bracket. For 1U or 2U PDUs, install cage nuts at the desired U location in the rack, then screw the PDU's mounting bracket ears into the RETMA rail surface where the cage nuts were installed.

  2. Establish a Reliable Ground Connection

    WARNING: To reduce the risk of electric shock due to high leakage currents, ensure a reliable grounded (earthed) connection before connecting the PDU to AC power. Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building or to the rack's grounding strip/bus bar. Ensure the bonding conductor meets minimum requirements based on the PDU's current rating (e.g., 12 AWG for up to 32A, 8 AWG for up to 63A).

  3. Attach Input Cord to Universal Input Connector (if applicable)

    If installing a Universal Input PDU, open the input cord connector latches on the PDU. Insert the facility-side input cord plug fully into the connector, then close the latches to securely lock the input cord into place.

  4. Connect the PDU to a Power Source

    WARNING: A risk of personal injury from electric shock and hazardous energy levels exists. This procedure must be performed by individuals knowledgeable about AC power products. 1. Turn OFF the feed circuit breaker for the branch circuit. 2. Ensure all circuit breakers on the PDU are set to the ON position. 3. Connect the PDU's input power cord to an appropriately rated, grounded (earthed) electrical outlet or dedicated branch circuit. 4. Turn ON the feed circuit breaker for the branch circuit. 5. Verify the PDU powers on. The OLED screen (if present) will display the Main Menu after loading, and Switched/Monitored & Switched PDUs will show lights corresponding to powered-up outlets.

  5. Configure Universal Input PDU Input Type (if applicable)

    If using a Universal Input PDU, configure its input type via the Web interface to ensure correct metering and power rating. 1. Access the PDU's Web interface (refer to the User Manual for connection instructions). 2. Navigate to the 'System Management' page under 'Settings'. 3. Select 'Set Input Cord' under 'Actions'. 4. Choose the correct cord type from the dropdown menu based on your installed input cord part number. 5. Select 'Save'. The PDU will reset to apply the new configuration.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.