Panduit P110VCM300 The Pan-Punch Vertical Cable Manager For Use With 300 Pair System is for use with…
UPC: 074983642618
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Designed for 300-pair cable applications in 110-style systems
- Vertical orientation maximizes space utilization and reduces clutter
- Compatible with Panduit Pan-Punch 110-style bases and connectors
- Constructed in the USA for durability and reliability
- Integrates seamlessly with existing structured cabling infrastructure
Specifications
Application | (1) Used to Connect, Manage, Identify and Cross-Connect Communications Equipment Wiring in Telecommunications Closets and Main Distribution Frames, (2) Used in Voice Networks and Data Local Area Networks |
Color | Black |
Connection Type | 110-style |
Depth | 7.18 In. |
Fits EMT* | NA IN |
Height | 23.93 IN |
Material | Polymer |
Material | Steel |
Material | Poly |
Mounting Type | Vertical |
Series | Pan-Punch 110-style |
Series | Pan-Punch Series |
Size | 300-pair |
Standard | RoHS Compliant |
Type | 110 System Cable Manager |
Width | 7.75 In. |
Package Dimensions (L x W x H) | 24.5 IN x 10.7 IN x 9.3 IN |
Package Weight (Imperial) | 8 lbs |

P110VCM900
The Pan-Punch Vertical Cable Manager For Use With 900 Pair System is for use with Pan-Punch 110-style Bases, Connectors and Systems.
CJ6X88TGIG
The Mini-Com Cat 6A UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is international gray.
CJ6X88TGAW
The Mini-Com Cat 6A UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is arctic white.
CJ6X88TGVL
The Mini-Com Cat 6A UTP RJ45 TG Jack Module is designed to terminate 4-pair, 22-26 AWG twisted pair cable. Each module is 100% factory tested to exceed industry standard performance requirements. TG style termination eliminates the need for a termination tool. Each jack is individually serialized for traceability and is compatible with Mini-Com Modular Patch Panels and Faceplates. The jack module is violet.
PVQ-FMTMTP-ZZ
The PViQ 24 port, OM4 optimized MTP fiber tray includes 24 LC SR./SR. 10 Gig SFF duplex multimode aqua adapters with zirconia ceramic split sleeves.
CMNZABL-X
The Mini-Com adapter snaps into 0.827 x 0.827 (21mm x 21mm) opening and accepts one Mini-Com module. Panel thickness should be 0.016 to 0.056 (1.17mm to 1.42mm). The adapter is black.
CMNZAWH-X
The Mini-Com adapter snaps into 0.827 x 0.827 (21mm x 21mm) opening and accepts one Mini-Com module. Panel thickness should be 0.016 to 0.056 (1.17mm to 1.42mm). The adapter is white.Frequently Asked Questions
What is the maximum number of pairs for the P110BW300-X?
The P110BW300-X supports up to 300 pairs.
What is the electrical performance standard for this product?
It exceeds all channel and component requirements of ANSI/TIA-568-C.2 Category 5e standard.
What type of cabling does the P110BW300-X support?
It is designed for use with unshielded twisted pair copper wire and cable.
What is the compatibility of the P110BW300-X?
The P110BW300-X is compatible with existing 110 installations.
How many cycles can the connecting block withstand?
The connecting block can withstand repeated terminations up to 200 cycles.
Can the P110BW300-X be used for small projects?
Yes, it can be used on jobs as small as 100-pair.
What installation features does the P110BW300-X have?
It features easy installation with color-coded wire strips for sorting and troubleshooting.
What is the maintenance requirement for the P110BW300-X?
The product includes features that assist in long-term maintenance, such as color-coded wire strips.
What is the temperature resistance of the P110BW300-X?
The product meets IEC 512-9b requirements for temperature life with minimal circuit resistance change.
Are there safety warnings for the P110BW300-X?
The documentation does not specify any safety warnings or precautions.
How to Install the P110VCM300 Pan-Punch 110 Tower System
Instructions for mounting and assembling the P110VCM300 Pan-Punch 110 Tower System.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers
Supplies needed:
#12 sheet metal screws, Cable ties, Connecting blocks, Ground lug, 1/4" x 3/4" machine screw, Nut, 1/4" external tooth lockwasher
- Mount the tower
Mount the tower to the wall using #12 wood screws or equivalent. Ensure the bottom of the tower is at least 8 inches from the floor to allow space for the horizontal cable manager trough. Note that some applications may require different mounting hardware.
- Route and secure cables
Route the cable bundle into the tower and fan out individual cables into their appropriate positions through the provided cutouts. Leave 12 to 18 inches of slack. Use cable ties to secure the bundle to the raised tabs on the back of the tower.
- Position and secure the base
Position the base over the slots in the tower and secure it with two #12 sheet metal screws. Place conductors into the index strip and install connecting blocks according to the instruction sheet PN51*.
- Install jumper troughs
Install jumper troughs between bases using two #12 sheet metal screws.
- Install cable managers and ground
Install vertical cable managers adjacent to the towers using #12 wood screws or equivalent. Attach the horizontal cable manager trough to the towers and vertical cable managers using #12 sheet metal screws and #12 external tooth lockwashers. Fasten securely to ensure grounding. Attach the ground lug (P/N:LAM2A2/0-14-6) with a 1/4" x 3/4" machine screw, nut, and 1/4" external tooth lockwasher to the bottom of the horizontal cable manager trough.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.