Panduit N8529BC - Net-Access N-Type Cabinet frame with top panel. Cage nut rails (12-24). Dual hinge perforated front door opens to the left or right. Split perforated rear doors open in the middle to minimize door swing footprint. Two sets of #12-24 cage nut equipment mounting rails. 45 RU cable management on front and rear of front posts. Dimensions: 84.0H x 31.5W x 48.0D (2134mm x 800mm x 1200mm). Color: Black, Two sets of SN25F fingers Included.
Panduit

N8529BC

UPC: 074983670444


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Panduit N8529BC Net-Access N-Type Cabinet frame offers a substantial 45 RU capacity for network and server infrastructure. Its dimensions are 84.0 inches high by 31.5 inches wide by 48.0 inches deep (2134mm x 800mm x 1200mm), finished in black. This enclosure includes a top panel for added environmental protection. Equipment mounting is facilitated by two sets of #12-24 cage nut rails, providing flexible installation options. Cable management is integrated with 45 RU capacity on both the front and rear of the front posts. The cabinet features a dual-hinged perforated front door that can open to the left or right, and split perforated rear doors designed to open in the middle, minimizing the door swing footprint in confined spaces. Two sets of SN25F fingers are included for efficient cable entry management. This Panduit cabinet is suitable for data centers, server rooms, and industrial environments requiring organized, high-density equipment deployment and structured cable pathways. It is compatible with standard 19-inch rackmount equipment and the broader Panduit Net-Access ecosystem.
  • 45 RU capacity for network and server equipment
  • Dual-hinged perforated front door (left/right swing)
  • Split perforated rear doors minimize footprint
  • Two sets of #12-24 cage nut mounting rails
  • Integrated 45 RU cable management on front/rear posts

Specifications

Color
Black
Depth
48 In.
Finish
Powder-coated
Material
Steel
Mounting Type
Rackmount
Mounting Type
Floor-standing
Mounting Type
Cage nut rails (12-24)
Series
Net-Access N-Type
Size
84.0H x 31.5W x 48.0D (2134mm x 800mm x 1200mm)
Standard
EIA-310-E, TIA/EIA-942, UL Listed 2416, RoHS Compliant
Type
N-Type Cabinet
Width
31.5 In.
Package Dimensions (L x W x H)
48 IN x 32 IN x 84 IN
Package Weight (Imperial)
464 lbs
Power supply for DIN-rail

PS-60

Power supply for DIN-rail
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included

3085

Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .

ST4803PDGM

Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
Ethernet SHDSL Extender

DDW-120

Ethernet SHDSL Extender
6U PERF PANEL

PPFS19010BK

6U PERF PANEL
Fiber cable ODC to SC duplex - 670mm

Fiber cable ODC SC Duplex 670mm

Fiber cable ODC to SC duplex - 670mm
DIN Rail ? DIN 35

ARH 1656

DIN Rail ? DIN 35
Cable Manager, fits 19-inch open rack, Black, Steel

ECK19H

Cable Manager, fits 19-inch open rack, Black, Steel
ON OFF SPST Nickel Pull Chain with Cord

75102CW

ON OFF SPST Nickel Pull Chain with Cord
This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.

STP6X12MIG

This TX6A 10Gig Cat 6A STP Patch Cord is a 12-Meter, Int'l Grey cord constructed of 26 AWG, shielded, twisted pair, stranded, CM/LSZH cable and with high-performance modular plugs. Its tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. The slender strain relief boot provides easy access in high-density applications. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL

F62ERLNSNSNM002

OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

CESUM3-C15

Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.

Frequently Asked Questions

What is the static load rating of the cabinets?

The static load rating is 3000 lbs for both N-Type and S-Type cabinets.

What is the rolling load rating of the cabinets?

The rolling load rating is 2500 lbs for both N-Type and S-Type cabinets.

How much time can be saved during cabinet installation?

The innovative leveling feet design can reduce installation time by up to 80%.

What safety features are included in the cabinets?

The cabinets are fully electrically bonded, requiring no grounding whips for protection of equipment and personnel.

What is the installation requirement for grounding?

The entire cabinet is fully integral bonded without the use of grounding wires.

What are the cabinet width options available?

Cabinets are available in widths of 600mm, 700mm, and 800mm.

What are the height options for the cabinets?

The cabinets come in heights of 42RU, 45RU, and 48RU.

Are the cabinets compatible with other Panduit products?

Yes, the cabinets are compatible with various Panduit product lines including FiberRunner® and Wyr-Grid®.

What is the benefit of the Integral Cabinet Top Cable Routing System?

It protects, routes, and manages large quantities of cables, reducing installation costs by up to 30%.

What type of doors do the cabinets have?

The cabinets feature front dual or single hinge doors with 69% open perforation.

How to Install the N8529BC Network Cabinet

This guide provides step-by-step instructions for the installation and initial setup of the N8529BC Network Cabinet, ensuring proper mounting, leveling, and grounding.

Estimated time: 1h

Tools needed:

Phillips screwdriver, Flatblade screwdriver, 22mm socket wrench, 15mm socket wrench, 13mm socket wrench, 8mm socket wrench, 48” Level, 7mm socket wrench, T30 Torx bit, T25 Torx bit, 6mm Allen key, 2.5mm Allen key, Wire cutter, 10mm socket wrench

Supplies needed:

Mounting screws, Shipping hold down brackets, Grounding lugs, Foam seals, M10 bolts

  1. Remove Packaging Material

    Remove all stretch wrap and protective cardboard from the outside of the cabinet. Use two persons to carefully lift and remove the cabinet from the pallet.

  2. Level the Cabinet

    Ensure that all four leveling legs are fully retracted. Slide the cabinet into its final position and lower the leveling legs until the cabinet is level front-to-back and side-to-side.

  3. Secure the Cabinet to the Floor

    If necessary, secure the shipping hold down brackets at the front and rear of the cabinet. Attach the anchors to the floor with appropriate hardware for your type of floor.

  4. Ground the Cabinet

    Attach a grounding lug or grounding bar to the Common Bonding Network (CBN) at any of the indicated locations. Use M5 bonding screws to fasten the grounding terminal to the cabinet frame.

  5. Install Equipment Rails

    Loosen the M10 hex head screws at the top and bottom of the rear equipment rail. Adjust the equipment rail to the desired position and tighten the screws to the specified torque.

  6. Install Optional Components

    If applicable, install the caster kit, PDU bracket kit, and any additional seals or cable management components as per the installation instructions provided.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.