Authorized Panduit Distributor
Panduit LD5IG10-A - The LD5 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 10 feet in length and is 1.01 inches wide by 0.58 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.

Panduit LD5IG10-A The LD5 Surface Raceway channel is a one-piece latching channel with integrated cover…

UPC: 074983729951


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Minimum Qty: 200

Multiplier: 200

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The Panduit Pan-Way® LD5 Surface Raceway channel (SKU: LD5IG10-A) is engineered for efficient and secure routing, protection, and concealment of data, voice, and video cabling in low-voltage applications up to 50V. Constructed from durable, rigid PVC, this one-piece channel features an integrated cover and a factory-applied adhesive backing for rapid and straightforward installation. Its dimensions are 10 feet in length, 1.01 inches in width, and 0.58 inches in depth, providing ample space for cabling management. The LD5 series is designed for routing data and low voltage cabling, offering a clean and organized aesthetic for any workspace. It meets TIA/EIA standards and is FT4 rated, ensuring compliance and safety. The International Gray color offers a neutral finish that blends well with various environments. This raceway system is ideal for applications requiring neat cable management without the need for complex mounting hardware, thanks to its peel-and-stick installation method. The one-piece hinged design allows cables to be easily laid in, simplifying the installation process and subsequent cable additions or modifications. Compatible with a range of Panduit fittings, including couplers, corner pieces, and end caps, the LD5 system provides a complete solution for complex routing requirements. Its robust construction ensures protection against physical damage, maintaining the integrity of your cabling infrastructure. Choose Panduit's LD5 Surface Raceway for a reliable, easy-to-install, and aesthetically pleasing cable management solution.
  • One-piece latching channel with integrated cover for easy cable access.
  • Factory-applied adhesive backing for fast and secure mounting.
  • Constructed of rigid PVC in International Gray for durability and aesthetics.
  • 10 feet length, 1.01 inches width, 0.58 inches depth for efficient cable management.
  • Designed for routing data, voice, and video cabling in applications up to 50V.

Specifications

Application
Surface Raceway products provide flexibility for routing, protecting, and consealing Low-Voltage Data, Fiber Optic and Electrical Wiring within any Enterprise Environment
Color*
International Gray
Cover Type
Single-Channel
Length
NA in
Material
Polyvinyl Chloride (PVC)
Standard
UL94V-0, FT4, Meets TIA/EIA Standards
Type
Low Voltage Channel
Type
Single Channel Surface Raceway
Width
1.01 in
Width
25.654 mm
Package Dimensions (L x W x H)
120 IN x 2.8 IN x 0.3 IN
Package Weight (Imperial)
0.83 lbs
The LD5 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.01 inches wide by 0.58 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.

LD5IG6-A

The LD5 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 6 feet in length and is 1.01 inches wide by 0.58 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.
Wire Safe Fitting - 3 inch X 3 Inch Internal Coupling.

EGCIL

Wire Safe Fitting - 3 inch X 3 Inch Internal Coupling.
Straight Section w/o KO - 10 x 10 x 48 - Steel/Gray

CWSC1048NK

Straight Section w/o KO - 10 x 10 x 48 - Steel/Gray
Closure Plate Feed-Through Wireway, 2.50x2.50, Gray, Mild Steel

F22WP

Closure Plate Feed-Through Wireway, 2.50x2.50, Gray, Mild Steel
The LD10 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 8 feet in length and is 1.5 inches wide by 0.94 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.

LD10IG8-A

The LD10 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 8 feet in length and is 1.5 inches wide by 0.94 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is International Gray.
Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.

T702BWH10

Twin-70 raceway base, 10 foot length. Supplied with pre-punched mounting holes. 2' of cover needed for every 1' of Twin-70 base.
The T-70 raceway base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 10 ft and White.

T70BWH10

The T-70 raceway base provides solutions for routing low voltage, fiber optic, and/or power cabling along perimeter walls. The T-70 raceway is supplied with pre-punched mounting holes and is tamper resistant. It is 10 ft and White.
The LD3 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 10 feet in length and is 0.77 inches wide by 0.46 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is White.

LD3WH10-A

The LD3 Surface Raceway channel is a one-piece latching channel with integrated cover and is designed to route, protect, and conceal data, voice, and video cabling. It features a factory-applied adhesive backing for fast mounting. It is 10 feet in length and is 0.77 inches wide by 0.46 inches deep. It meets TIA/EIA, used in applications up to 50 V. It is constructed of rigid PVC and is White.

Frequently Asked Questions

What is the operating temperature range?

The operating and storage temperature range is 0° to 50°C.

What is the voltage rating of the DCF10WH-X?

The voltage rating for the DCF10WH-X is 50V or less.

How is the DCF10WH-X installed?

It features an adhesive backing for easy, tool-free installation.

Is the DCF10WH-X resistant to corrosion?

Yes, the non-metallic construction will not rust or corrode.

What materials are used in the DCF10WH-X?

The DCF10WH-X is made of rigid PVC, which is impact resistant.

What types of cables can be routed through the DCF10WH-X?

It can route low voltage data, voice, and video cabling.

What is the design of the DCF10WH-X?

It features a one-piece hinged design for easy cable installation.

What colors are available for the DCF10WH-X?

The DCF10WH-X is available in Off White, Electrical Ivory, and White.

Can the DCF10WH-X be painted?

Yes, the raceway is field paintable to match walls and décor.

What is the maximum cable fill for LD10 raceway?

The maximum cable fill for LD10 raceway is 24 AWG/UTP up to 13 cables.

How to Install the LD5IG10-A PAN-WAY Surface Raceway

Instructions for installing and mounting the LD5IG10-A PAN-WAY Surface Raceway fittings.

Estimated time: 30m

Tools needed:

Screwdriver, Utility knife, Measuring tape

Supplies needed:

Mounting screws, LD5IG10-A fittings

  1. Plan the Raceway Layout

    Determine the desired path for the raceway. Measure and mark the mounting locations. Ensure the path is clear of obstructions.

  2. Prepare the Mounting Surface

    Clean the mounting surface to ensure good adhesion. If drilling is required, mark the hole locations accurately based on your plan.

  3. Mount the Raceway Base

    Using the appropriate mounting screws, securely attach the base of the LD5IG10-A raceway fitting to the prepared surface. Ensure it is level and firmly fixed.

  4. Install Fittings and Accessories

    Connect additional raceway sections or fittings as needed. Ensure all connections are snug and form a continuous pathway. For conduit openings, use a utility knife to carefully score and remove the knockout material.

  5. Route Wires

    Carefully place the low voltage or power cables within the installed raceway. Do not overfill the raceway, and ensure cables are not pinched or damaged.

  6. Attach the Cover

    Snap or slide the cover of the LD5IG10-A raceway into place over the base and wires. Ensure the cover is fully secured along its entire length.

  7. Verify Installation

    Visually inspect the entire installation to ensure all components are securely fastened and the raceway is properly aligned. Check that no wires are exposed.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.