Authorized Panduit Distributor
Panduit FXURPENENXNF091 - OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method A, Optimized IL, 91 ft, Aqua
Panduit

FXURPENENXNF091

UPC: 613056191143


Documents & Media
Technical DrawingFull Engineering DrawingSpecification Sheet

Contact for Pricing

Overview

Panduit FXURPENENXNF091 is a high-density OM3 multimode plenum-rated interconnect cable engineered for demanding 10G/40G/100G Ethernet, Fibre Channel, and other high-speed data transmission applications. This robust 24-fiber MPO-to-MPO cable is configured with Method A polarity, also known as Type A, which ensures a direct fiber mapping. It is specifically designed with optimized insertion loss (IL) to guarantee superior signal integrity and minimize performance degradation within critical data center and enterprise network infrastructures. The cable's 91-foot (27.7-meter) length offers significant installation flexibility, facilitating efficient rack-to-rack or row-to-row connections within complex structured cabling systems. The distinctive aqua-colored jacket adheres to stringent UL 910 plenum fire safety standards, confirming its suitability for installation in air-handling spaces where fire retardancy is paramount. Each of the 24 individual fibers is precisely terminated with a 24F MPO female connector. This specific connector type is essential for ensuring seamless compatibility with a wide range of MPO/MTP-based transceivers, network switches, and patch panel systems. The FXURPENENXNF091 is an ideal solution for high-density environments where maximizing rack space utilization and achieving peak network performance are absolute critical requirements.
  • 24 multimode OM3 fibers optimized for 10G/40G/100G Ethernet and Fibre Channel
  • Plenum-rated (UL 910) for use in air-handling spaces
  • Method A polarity (Type A) for direct MPO-to-MPO connections
  • Optimized insertion loss for reliable high-speed signal transmission
  • Aqua jacket for easy identification in structured cabling systems

Specifications

Application
OM3
Color
Aqua
Connection Type
MPO Female to MPO Female
Connector 1 Type*
MPO Female
Connector 2 Type*
MPO Female
Fiber Compatibility*
OM3 50/125um
Fiber Count*
24
Length
91 FT
Material
Plenum
Poles
24F MPO Female
Size
91 ft
Standard
Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5(FOCIS-5), TIC/EIA-568-C.1, RoHS Complain
Temperature Rating
158 F
Type
Interconnect Cable Assembly
Package Dimensions (L x W x H)
14 IN x 17 IN x 1.5 IN
Package Weight (Imperial)
0.89 lbs
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method A, Optimized IL, 59 ft, Aqua

FXURPENENXNF059

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method A, Optimized IL, 59 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 55 ft, Aqua

FXURPENENYNF055

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 55 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 15 ft, Aqua

FXURPENENYNF015

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 15 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method A, Optimized IL, 92 ft, Aqua

FXURPENENXNF092

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method A, Optimized IL, 92 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 17 ft, Aqua

FXURPENENYNF017

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 17 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 53 ft, Aqua

FXURPENENYNF053

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 53 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 57 ft, Aqua

FXURPENENYNF057

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 57 ft, Aqua
OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 58 ft, Aqua

FXURPENENYNF058

OM3 24 fiber, Interconnect, Plenum, 24F MPO Female to 24F MPO Female, Method B, Optimized IL, 58 ft, Aqua

Frequently Asked Questions

What is the operating temperature range?

The operating temperature range is 0 °C to +70 °C (32°F to +158°F).

What types of fiber are available?

The product supports Multimode (OM3, OM4) and Singlemode (OS2) fiber types.

What is the maximum cable attenuation for Singlemode?

The maximum cable attenuation for Singlemode is 1.0dB/km at 1310/1550nm.

What is the minimum bend radius for installation?

The minimum bend radius under load is 20 times the cable outside diameter.

How many mating cycles can the connectors endure?

The connectors are durable for up to 500 mating cycles.

What is the cable outside diameter?

The cable outside diameter is 3.6mm.

What are the storage temperature requirements?

The storage and shipping temperature range is -40 °C to +70 °C (-40°F to +158°F).

What standards does this product meet?

The product meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, and RoHS compliance.

What is the maximum connector insertion loss for Multimode?

The maximum connector insertion loss for Multimode is 0.35dB.

What is the tensile strength of the cable?

The cable tensile strength is 50 lbf.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.