Authorized Panduit Distributor
Panduit FWTRP7N7NKNF062 - OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 62 Feet
Panduit

FWTRP7N7NKNF062

UPC: 613056344877


Documents & Media
Specification Sheet

Contact for Pricing

Overview

Panduit FWTRP7N7NKNF062 is a 12-fiber OM5 plenum-rated interconnect cable designed for high-density data center and enterprise applications. This Method A polarity cable features PanMPO female connectors on both ends, ensuring compatibility with OM5-compliant optical systems while meeting strict fire safety requirements for plenum spaces. The 62-foot length provides flexible deployment in structured cabling architectures, supporting 100Gb/s and 400Gb/s applications over OM5 multimode fiber. With ultra-low insertion loss specifications, this interconnect minimizes signal degradation in high-speed networks. The plenum-rated jacket (UL 910) resists flame propagation and smoke generation, making it suitable for air-handling spaces. Ideal for data center interconnects, backbone cabling, and high-density switch-to-switch connections where performance and safety compliance are critical. Compatible with Panduit's PanMPO ecosystem and OM5 fiber standards.
  • 12-fiber OM5 multimode fiber with PanMPO female connectors
  • Plenum-rated (UL 910) for installation in air-handling spaces
  • Method A polarity for direct fiber mapping compatibility
  • 62-foot length for flexible deployment in structured cabling
  • Ultra-low insertion loss for high-speed network performance

Specifications

Application
Data centers requiring quick infrastructure deployment with extended reach that want to maintain bandwidth throughout the infrastructure.
Color
Lime Green
Connection Type
PanMPO Female to PanMPO Female
Environmental Conditions
Indoor
Poles
12 fiber
Series
OM5
Size
62 Feet
Standard
Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-5), TIA/EIA-568-C.1, RoHS compliant for OM4 ANSI/TIA-492AAAE, IEC 60793-2-10 Ed 6, TIA 568.3-D, ISO 11801 Ed 3, RoHS compliant for OM5
Type
Interconnect Cable Assembly
Package Dimensions (L x W x H)
14 IN x 17 IN x 1.5 IN
Package Weight (Imperial)
0.608 lbs
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 31 Feet

FWTRP7N7NKNF031

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 31 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 57 Feet

FWTRP7N7NLNF057

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 57 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 57 Feet

FWTRP7N7NKNF057

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 57 Feet
OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 8 Meters

FWTRL7N7NKNM008

OM5, 12 Fiber Interconnect, Low Smoke Zero Halogen, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 8 Meters
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 55 Feet

FWTRP7N7NLNF055

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 55 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 59 Feet

FWTRP7N7NLNF059

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 59 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 55 Feet

FWTRP7N7NKNF055

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method A, Ultra Insertion Loss - 55 Feet
OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 31 Feet

FWTRP7N7NLNF031

OM5, 12 Fiber Interconnect, Plenum, PanMPO Female to PanMPO Female, Method B, Ultra Insertion Loss - 31 Feet

Frequently Asked Questions

What jacket ratings are available for the patch cords?

The patch cords are available with Plenum (OFNP), Riser (OFNR), and Low Smoke Zero Halogen (LSZH) jacket ratings.

What is the minimum bend radius for the cable?

The minimum bend radius for the cable is 32mm, with a long-term minimum bend radius of 16mm.

What is the operating temperature range for the patch cords?

The operating and installation temperature range for the patch cords is -10°C to 60°C (14°F to 140°F).

What is the connector durability of the patch cords?

The connectors have a durability of 500 cycles.

Are these patch cords RoHS compliant?

Yes, all patch cord components meet the requirements of Directive 2002/95/EC for RoHS compliance.

What is the cable outside diameter?

The cable outside diameter (OD) for the duplex patch cords is 1.6mm.

How does OM4 Signature Core™ fiber improve reach?

OM4 Signature Core™ provides 20% greater reach over standard un-compensated OM4 fiber, supporting 600m with 10GBASE-SR transceivers.

How does OM5 Signature Core™ fiber improve reach?

OM5 Signature Core™ provides 15% longer reach than standard OM5 for applications using Short Wavelength Division Multiplexing (SWDM).

How does OM5 Signature Core™ fiber improve reach?

OM5 Signature Core™ provides 15% longer reach than standard OM5 for applications using Short Wavelength Division Multiplexing (SWDM).

How does OM4 Signature Core™ fiber improve reach?

OM4 Signature Core™ provides 20% greater reach over standard un-compensated OM4 fiber, supporting 600m with 10GBASE-SR transceivers.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.