Authorized Panduit Distributor
Panduit FW2ERQ1Q1NNF028 - OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 38f, 28 ft.
Panduit

FW2ERQ1Q1NNF028

UPC: 613056342798


Documents & Media
Specification Sheet

Contact for Pricing

Overview

The Panduit FW2ERQ1Q1NNF028 OM5 fiber optic cable delivers high-speed data transmission for data centers and enterprise networks. This 2-fiber, 1.6mm diameter plenum-rated (OFNR) cable features LC/PushPull connectors with standard polarity, optimized for 40G/100G Ethernet and other high-bandwidth applications. The cable meets or exceeds ISO/IEC 11801, ANSI/TIA-568.3-D, and IA/EIA-604 (FOCIS-3 and FOCIS-10) standards, ensuring compatibility with structured cabling systems. Constructed with ultra-performance specifications, it supports superior durability and network reliability with low insertion loss. The 28-foot length provides ample reach for structured cabling deployments, while the PushPull connectors simplify installation and maintenance, reducing downtime. Engineered for high-speed data transmission, this OM5 multimode fiber cable ensures compliance with fire safety standards, making it ideal for plenum environments where safety and performance are critical. The standard polarity configuration ensures consistent and error-free signal routing in high-density network infrastructure. RoHS-compliant components meet Directive 2002/95/EC for environmental safety.
  • 2-fiber OM5 multimode cable optimized for 40G/100G Ethernet
  • 1.6mm diameter plenum-rated (OFNR) construction for safety and performance
  • LC/PushPull connectors with standard polarity for easy installation
  • Meets ISO/IEC 11801, ANSI/TIA-568.3-D, and FOCIS standards
  • 28-foot length with low insertion loss for reliable data transmission

Specifications

Application
Provide interconnect and cross-connect of applications in entrance facilities, telecommunication rooms, data centers, and network applications to interconnect pre-terminated cassettes in main distribution, horizontal distribution, and equipment distributio
Color
Lime Green
Connection Type
LC/PushPull LC
Depth
336 IN
Enclosure
Optical Fiber Non-Conductive Riser (OFNR)
Height
0.06 in
Material
Fiber Optic
Model
LC Push-Pull
Poles
2
Series
OM5
Size
1.6mm diameter, 28 ft
Slot Capacity
NA
Standard
Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3, TIA-604-5 (FOCIS-10), TIA/EIA-568-C.1, RoHS compliant for OM4 ANSI/TIA-492AAAE, IEC 60793-2-10 Ed 6, TIA 568.3-D, ISO 11801 Ed 3, RoHS compliant for OM5
Type
Fiber Optic Patch Cord
Width
0.06 IN
Package Dimensions (L x W x H)
0.001 IN x 0.001 IN x 0.001 IN
Package Weight (Imperial)
0.181 lbs
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 37f, 27 ft.

FW2ERQ1Q1NNF027

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 37f, 27 ft.
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 14m

FW2ERQ1Q1NNM014

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 14m
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 43f

FW2ERQ1Q1NNF043

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 43f
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 48f

FW2ERQ1Q1NNF048

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 48f
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 25m

FW2ERQ1Q1NNM025

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 25m
OM5 2f 1.6mm PC LSZH PushPull LC/PushPull LC Std Polarity Ult Perf 8m

FW2ELQ1Q1NNM008

OM5 2f 1.6mm PC LSZH PushPull LC/PushPull LC Std Polarity Ult Perf 8m
OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 37f, 26 ft.

FW2ERQ1Q1NNF026

OM5 2f 1.6mm PC OFNR PushPull LC/PushPull LC Std Polarity Ult Perf 37f, 26 ft.
OM5 2f 1.6mm PC LSZH PushPull LC/PushPull LC Std Polarity Ult Perf 11m

FW2ELQ1Q1NNM011

OM5 2f 1.6mm PC LSZH PushPull LC/PushPull LC Std Polarity Ult Perf 11m

Frequently Asked Questions

What fiber types are available for these patch cords?

The Opti-Core Push-Pull LC Duplex Fiber Optic Patch Cords are available in OM1, OM3, OM4, OM4+ Signature Core™, OM5, and OS2 fiber types.

What is the maximum standard insertion loss for OS2 fiber?

The maximum standard connector insertion loss for OS2 fiber is 0.25 dB.

What is the purpose of the push-pull design?

The custom push-pull strain relief boot and duplex clip allow for easy accessibility when deploying very high-density LC patch fields in data center applications.

What are the benefits of OM4+ Signature Core™ fiber?

OM4+ Signature Core™ provides on average 20% longer reach than standard OM4 for applications using Ethernet, Fibre Channel, and Cisco BiDi technologies.

How many mating cycles can the connectors withstand?

The connectors on these patch cords have a durability of 500 cycles.

What is the minimum return loss for singlemode fiber?

The minimum connector return loss for singlemode fiber is 55dB.

What is the minimum return loss for multimode fiber?

The minimum connector return loss for multimode fiber is 26dB.

What is the maximum standard insertion loss for OM3, OM4, OM5 fibers?

The maximum standard connector insertion loss for OM3, OM4, and OM5 fibers is 0.15 dB.

What is the storage temperature range for the patch cords?

The storage and shipping temperature range for the patch cords is -40°C to 70°C.

What is the operating temperature range for these patch cords?

The operating and installation temperature range for these patch cords is -10°C to 60°C.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.