Panduit FSCSCBU SC 9/125 m singlemode simplex connector for 900 m tight-buffered fiber installation.
UPC: 074983214693
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- SC Simplex connection type for singlemode fiber
- Designed for 900 µm tight-buffered fiber
- Durable plastic/composite material construction
- Reliable data transmission with low insertion loss
- Manufactured in the USA
Specifications
Application | Maintenance or emergency restoration of fiber networks and retrofit/initial install in both behind-the-wall (BTW) and in the permanent side of panelized interconnect and cross-connect. |
Boot Color* | Blue |
Color | Blue |
Connection | SC |
Connector 1 Type* | SC |
Connector 2 Type* | Ceramics |
Fiber Type | OS1/OS2 |
Insertion Loss | 0.3 dB |
Special Features | Factory pre-polished fiber endface eliminates time-consuming field polishing |
Standard | TIA/EIA-604 FOCIS-3 compliant, exceeds TIA/EIA-568-B.3 performance requirements |
Temperature Rating | 140 F |
Type | SC Simplex Connector |
Package Dimensions (L x W x H) | 3.5 IN x 5 IN x 1 IN |
Package Weight (Imperial) | 0.025 lbs |

FSCS2.0BU
SC singlemode simplex fiber optic connector for 1.6mm 2.0mm jacketed cable or 900 m buffered fiber installation.
FSCDMCXAQ
SC multimode duplex fiber optic connector for 900m tight buffered cable installation, Aqua.
FSCMCXAQ
The SC 50/125 m OM3/OM4 multimode simplex connector in aqua is designed for 900-micron tight-buffered fiber installations. It is intended for use in fixed installations that are outside the scope of the RoHS directive.
FLCDM900EIY
The duplex field polish LC Fiber Optic Connector is intended for installation onto multimode 62.5/125?m, 900 m tight-buffered fiber. The LC connector has an electric ivory body with an electric ivory 900 m boot.
FLCDMCXAQY
The OptiCam LC Fiber Optic Connector is a multimode 50/125?m OM3/OM4/OM5 duplex fiber connector, intended for 900-micron tight-buffered fiber installation. Field termination can be done in about two minutes using the OptiCam 2 Termination Tool. The pre-polished fiber endface eliminates time-consuming field polishing, reducing installation costs. The LC connector has a natural-colored body with an aqua-colored backbone and 900?m boot.
FLCDMEIY
The duplex field polish LC Fiber Optic Connector is intended for installation onto multimode 62.5/125?m, 1.6mm jacketed fiber. The LC connector has an electric ivory body with an electric ivory 1.6mm boot.Frequently Asked Questions
What is the average insertion loss for connectors?
The average insertion loss is 0.3dB per mated pair for both multimode and singlemode fiber.
What types of fiber are compatible with this product?
Compatible fiber types include 62.5/125μm OM1, 50/125μm OM2, OM3, OM4, OM5, and 9/125μm OS1/OS2.
What is the operating temperature range?
The operating temperature range is 32°F to 140°F (0°C to 60°C).
What is the return loss for singlemode fiber?
The return loss for singlemode fiber is greater than 50dB.
Are the connectors compliant with industry standards?
Yes, the connectors are ANSI/TIA-604-FOCIS-3 compliant and exceed ANSI/TIA-568.3-D requirements.
How many re-terminations can be performed?
The connectors allow for up to two re-terminations with no degradation in performance.
What cable sizes are supported?
Supported cable sizes are 1.6mm - 2.0mm and 3.0mm jacketed cable with optional boots.
What is the maximum insertion loss after repeated mating?
The maximum insertion loss after repeated mating is 0.75dB.
What tools are needed for installation?
The installation requires the OptiCam® 2 Termination Tool for optimal performance.
What is the mechanical cable retention capability?
The connectors provide higher than industry standard cable retention without the need for adhesive.
How to Terminate Panduit OptiCam Fiber Optic Connectors
Step-by-step guide for terminating Panduit OptiCam connectors onto fiber optic cables.
Estimated time: 1h
Tools needed:
OptiCam Termination Tool (OCTT), SC Cradle for OptiCam Termination Tool (OCTT), 2.5mm Universal Patch Cord for OptiCam Termination Tool (OCTT), Fiber Cable Jacket Stripper, Fiber Buffer Stripper, Fiber Cleaver Tool, Fine-Tip Marking Pen
Supplies needed:
Isopropyl Alcohol (90% minimum concentration), Lint-Free Wipes, Safety Glasses, 900μm boots, Build-up tube (for 250μm fiber), Fanout Kit (for jacketed cable), Adhesive (Loctite 401 or equivalent Cyanoacrylate adhesive), Duplex Clip (optional)
- Prepare the Fiber Optic Cable
For 250μm fiber: Place a 900μm boot onto the fiber, then a build-up tube. Mark the build-up tube 15mm (LC) or 11mm (SC/ST) from its end. Strip at least 30mm of coating from the fiber and clean with an alcohol-soaked wipe. Mark the coated fiber 15mm (LC) or 11mm (SC/ST) from the end of the stripped coating. Cleave the fiber 7mm from the end of the coating. For jacketed cable: Split duplex cable if necessary. Mark the cable jacket 1.73" (44mm) from the end and strip. Fold aramid yarn back over the jacket. Mark the buffer 0.55" (14mm) from the jacket edge, and then mark 0.43" (11mm) from that mark. Mark the buffer at the edge of the jacketing. Strip the buffer to the 0.55" (14mm) mark. Clean the bare fiber with an alcohol-soaked wipe. Cleave the fiber 7mm from the end of the buffer coating.
- Prepare the OptiCam Termination Tool
Ensure the laser switch on the OCTT is OFF. Remove the protective dust cover from the laser. Insert the ST end of the FVFLPC-2.5SMY patch cord into the laser aperture, aligning the tabs, and rotate the barrel clockwise to lock. Align the SC Cradle with the OCTT cradle holder and slide it under the tabs until it stops. Grip the cradle holder and slide it to the pre-termination position.
- Insert Connector and Fiber into Cradle
Remove dust caps from the connector inner housing assembly. Place the inner housing assembly into the SC cradle, ensuring the connector housing tabs are between the cradle forks. Attach the patch cord to the connector ferrule by gently sliding the ferrule adapter end over the connector ferrule until it stops, ensuring it is in-line and not at an angle.
- Terminate the Connector
For 900μm tight-buffered fiber: Insert the fiber into the connector body with light pressure until it stops on the fiber stub. The insertion mark should be near the back of the connector. Squeeze clamp arms to open pads, place the fiber between them, and release the arms to clamp the cable. Shuttle the cradle holder towards the cable to create a bow in the fiber. For jacketed cable: Insert the fiber into the connector body until it stops. Ensure the buffer length mark is at the edge of the jacket. Squeeze clamp arms to open pads, place the cable between them, and release the arms to clamp the cable. Do not shuttle the cradle holder for jacketed cable terminations.
- Cam and Test the Connector
Turn the OCTT laser ON. Rotate the cam lever 90° counterclockwise until it stops. The glow from the connector cam region should dim or remain dark. If not, turn the laser OFF, un-cam the connector, adjust fiber position, and re-cam. Turn the OCTT laser OFF. Remove the ferrule adapter end of the patch cord from the connector.
- Assemble and Finish
Remove the connector from the cradle. For 900μm fiber, slide the boot forward onto the backbone until it seats against the flange. For jacketed cable, flare aramid yarn, then push the boot forward and thread it onto the backbone. Align the inner and outer housing assemblies and push them together until they snap. Clean the ferrule end face and place a dust cap on it. Attach the duplex clip if desired. Dispose of fiber scraps properly.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.