Contact for Pricing
Minimum Qty: 5
Multiplier: 1
*Contact for lower quantities*
Overview
- Designed for 12x4 FiberRunner channels
- Used with FRSPJ4X4LBL spill-over junction
- Provides full enclosure for the channel
- Constructed from durable FiberRunner material
- Ensures secure and contained fiber optic cable management
Specifications
Application | Data Centers and Telco Central Offices |
Height | 4.88 in |
Height | 123.952 mm |
Length | 13.63 in |
Length | 346.202 mm |
Material | Polycarbonate/ABS |
Standard | RoHS Compliant, UL Listed to 2024 Optical Fiber Cable Routing Assemblies Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3 |
Type | Fiber Routing Spill-Over Junction Cover |
Width | 15 in |
Width | 381 mm |
Package Dimensions (L x W x H) | 22 IN x 16 IN x 5 IN |
Package Weight (Imperial) | 1.93 lbs |

FRSPJC412LYL
The FiberRunner Spill-Over Junction is used to fully enclose a 12x4 channel when used with the spill-over junction FRSPJ4X4LYL.Frequently Asked Questions
What are the primary applications for the 12x4 system?
It is suited for data centers and Telco Central Offices to route fiber optic and high performance copper cabling, including underfloor applications.
How does the system facilitate maintenance and changes?
Hinged channel covers and split fitting covers provide fast and easy access for future cabling moves, adds, and changes.
How does the QuikLock™ Coupler simplify installation?
QuikLock™ Couplers and Brackets make mechanically secure connections in less than five seconds without tools or bolts.
What safety approvals does the FiberRunner system have?
The system is UL Listed to 2024 Optical Fiber Cable Routing Assemblies.
What is the flammability rating of the system?
The FiberRunner 12x4 system has a flammability rating of 94V-0.
What materials are used for the FiberRunner system?
The channel is made of Rigid PVC, and the fittings are made of PC/ABS.
Where can FiberRunner system components be attached?
Components can attach to ladder rack, threaded rod, auxiliary framing, strut, equipment racks, cabinets, and raised floor pedestals.
What colors are available for the FiberRunner 12x4 system?
The FiberRunner 12x4 system is available in yellow and black.
What bend radius do FiberRunner fittings maintain?
Fittings maintain a minimum 2 inch bend radius to protect against signal loss due to excessive cable bends.
How are FiberRunner channel and fittings assembled?
Channel and fittings are assembled using pre-assembled QuikLock™ Couplers, requiring no tools or bolts.
How to Install the FiberRunner Spill-Over Junction
This guide provides step-by-step instructions for installing the FiberRunner Spill-Over Junction for use with Panduit FiberRunner cable routing systems.
Estimated time: 45m
Tools needed:
Screwdriver, Torque wrench, Drill
Supplies needed:
¼-20 T-Bolts, ¼-20 Hex KEPS Lock Nuts, ¼-14x½ Hex Washer Head Tapping Screws
- Prepare the installation site
Ensure the installation area is clean and free of debris. Identify the location for mounting the FiberRunner Spill-Over Junction.
- Mount the junction
Secure the FiberRunner Spill-Over Junction to the support bracket using ¼-20 T-Bolts and ¼-20 Hex KEPS Lock Nuts. Ensure the head of the T-Bolt is completely seated flush against the support bracket.
- Tighten the fasteners
Using a torque wrench, tighten the T-Bolts to a maximum torque of 5 ft./lbs. to ensure a secure installation.
- Install the channel cover
Attach the FiberRunner Spill-Over Junction Channel Cover by aligning it with the junction and securing it with the appropriate screws.
- Verify installation
Check that all components are securely fastened and that the junction is properly aligned with the FiberRunner system.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.