Panduit FRSPJC24LBL - The FiberRunner Spill-Over Junction Cover is used to fully enclose 4x4 channel in conjunction with the FiberRunner Spill-Over Junction FRSPJ2X2LBL. The cover snaps onto the channel base. The hinged feature provides easy access to add or remove cables.
Panduit

FRSPJC24LBL

UPC: 613056768048


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification SheetVideo Clip

Contact for Pricing

Minimum Qty: 5

Multiplier: 1

*Contact for lower quantities*

Overview

The Panduit FiberRunner Spill-Over Junction Cover (SKU: FRSPJC24LBL) is engineered to provide a complete enclosure solution for 4x4 FiberRunner channels when used in conjunction with the FiberRunner Spill-Over Junction (FRSPJ2X2LBL). This cover is designed for straightforward installation, snapping directly onto the channel base for a secure fit. Its key feature is the integrated hinged design, which facilitates easy access for adding or removing fiber optic cables without requiring complete disassembly. This functionality is crucial for maintaining network integrity and simplifying cable management during network expansions or modifications. The FRSPJC24LBL ensures that the spill-over junction area within the 4x4 channel remains fully enclosed, protecting the fiber optic infrastructure from environmental factors and physical damage. Manufactured in the US, this component is part of the comprehensive Panduit FiberRunner system, known for its efficient and organized cable routing capabilities. The spill-over junction cover is an essential accessory for any data center or telecommunications environment utilizing the FiberRunner system for high-density fiber optic deployments, ensuring both accessibility and protection for critical cabling pathways.
  • Fully encloses 4x4 FiberRunner channel
  • Designed for use with FiberRunner Spill-Over Junction FRSPJ2X2LBL
  • Snaps onto channel base for secure installation
  • Hinged design allows easy cable access
  • Manufactured in the US

Specifications

Application
Data Centers and Telco Central Offices
Color
Blue
Height
4.7 in
Height
119.38 mm
Length
5.24 in
Length
133.096 mm
Material
Poly
Material
Polycarbonate/ABS
Series
FiberRunner Spill-Over Junction Cover
Size
4X4
Standard
RoHS Compliant, UL Listed to 2024 Optical Fiber Cable Routing Assemblies Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3
Type
Fiber Routing Spill-Over Junction Cover
Width
9 in
Width
228.6 mm
Package Dimensions (L x W x H)
10 IN x 10 IN x 5 IN
Package Weight (Imperial)
0.26 lbs
The FiberRunner Spill-Over Junction Cover is used to fully enclose 4x4 channel in conjunction with the FiberRunner Spill-Over Junction FRSPJ4X4LBL. The cover snaps onto the channel base. The hinged feature provides easy access to add or remove cables.

FRSPJC44LBL

The FiberRunner Spill-Over Junction Cover is used to fully enclose 4x4 channel in conjunction with the FiberRunner Spill-Over Junction FRSPJ4X4LBL. The cover snaps onto the channel base. The hinged feature provides easy access to add or remove cables.
PVC Coated Cable Tray Conduit Clamp, Conduit Size 3/4 Inch, Gray

LCC2-G

PVC Coated Cable Tray Conduit Clamp, Conduit Size 3/4 Inch, Gray

Frequently Asked Questions

What structures can QuikLock Brackets attach system components to?

Brackets can attach components to ladder rack, threaded rod, auxiliary framing, strut, equipment racks, cabinets, and raised floor pedestals.

What is the 50% fill capacity for 1.6mm Fiber Optic Ribbon?

The system has a 50% fill capacity of 2,824 cables for 1.6mm Fiber Optic Ribbon.

What is the 50% fill capacity for 3.0mm Category 6 cables?

The system has a 50% fill capacity of 803 cables for 3.0mm Category 6 cables.

What is the UL listing for the FiberRunner 4x4 Routing System?

It is UL Listed to 2024 Optical Fiber Cable Routing Assemblies.

What types of cabling can the FiberRunner 4x4 system protect?

It protects fiber optic and high performance copper cabling.

How are channel and fittings assembled in this system?

Channel and fittings are assembled using pre-assembled QuikLock™ Couplers, which require no tools or bolts.

What colors are available for the FiberRunner 4x4 Routing System?

The available system colors are yellow and black.

What is the minimum bend radius maintained by the fittings?

All fittings maintain a minimum 2-inch bend radius to protect against signal loss due to excessive cable bends.

What is the flammability rating of the FiberRunner 4x4 system?

The system has a flammability rating of 94V-0.

What materials are used for the FiberRunner 4x4 system components?

The channel is made of rigid PVC, and the fittings are made of PC/ABS.

How to Install the FiberRunner Spill-Over Junction

This guide provides step-by-step instructions for installing the FiberRunner Spill-Over Junction in a cable routing system.

Estimated time: 45m

Tools needed:

Screwdriver, Torque wrench, Drill

Supplies needed:

¼-20 T-Bolts, ¼-20 Hex KEPS Lock Nuts, ¼-14x½ Hex Washer Head Tapping Screws

  1. Mount the Spill-Over Junction

    Secure the Spill-Over Junction to the FiberRunner system using ¼-20 T-Bolts and ¼-20 Hex KEPS Lock Nuts. Ensure the junction is level and properly aligned.

  2. Tighten the Fasteners

    Using a torque wrench, tighten the T-Bolts to a maximum torque of 5 ft./lbs. Ensure that the head of the T-Bolt is completely seated flush against the support bracket.

  3. Install the Junction Channel Cover

    Attach the Junction Channel Cover to the Spill-Over Junction. Ensure it is securely fastened and operates smoothly.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.