Contact for Pricing
Minimum Qty: 5
Multiplier: 1
*Contact for lower quantities*
Overview
- Designed for use with 4x4 FiberRunner fittings
- Routes cables into three 1.5-inch diameter split corrugated tubes
- Facilitates organized cable pathways
- Minimizes bend radius stress on cables
- Manufactured in the USA
Specifications
Application | Data Centers and Telco Central Offices |
Application | For use with 4X4 CHANNEL and 4X4 COUPLER |
Height | 3.53 in |
Height | 89.662 mm |
Length | 4.64 in |
Length | 117.856 mm |
Material | Polycarbonate/ABS |
Series | FiberRunner |
Size | 1.5 inch (3.8 mm) diameter split corrugated tubing |
Standard | RoHS Compliant, UL Listed to 2024 Optical Fiber Cable Routing Assemblies Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3 |
Type | 2-Port Spillout |
Width | 5.42 in |
Width | 137.668 mm |
Package Dimensions (L x W x H) | 6.2 IN x 5.6 IN x 4.2 IN |
Package Weight (Imperial) | 0.65 lbs |

FRIDT4X4LYL
The FiberRunner 2-Port Spillout is used with a 4x4 fitting. The spillout is used to route cable into two separate 1.5 inch (3.8mm) diameter split corrugated tubing.Frequently Asked Questions
What is the FRIDT4X4LBL component?
The FRIDT4X4LBL is a 2-port spillout designed for 1.5 inches I.D. corrugated tubing, part of the FiberRunner 4x4 system.
What approvals does the FiberRunner 4x4 system have?
The system is UL Listed to 2024 Optical Fiber Cable Routing Assemblies.
What structures can FiberRunner 4x4 components attach to?
System components can attach to ladder rack, threaded rod, auxiliary framing, strut, equipment racks, cabinets, and raised floor pedestals.
Where can the FiberRunner 4x4 system be deployed?
It can be deployed in data centers, Telco Central Offices, over racks, or in approved underfloor applications.
What is the cable capacity for Category 6A (6.35mm) cables?
The 4x4 routing system has a 50% fill capacity of 179 Category 6A (6.35mm) cables.
What is the cross-sectional area of the channel?
The cross-sectional area of the channel is 17.6 in.² (11,354mm²).
What colors are available for the FiberRunner 4x4 system?
The FiberRunner 4x4 Routing System is available in yellow and black colors.
What bend radius do fittings maintain for cable protection?
All fittings maintain a minimum 2 inches bend radius to prevent excessive bends in fiber optic cabling and protect against signal loss.
What is the flammability rating of the system?
The FiberRunner 4x4 Routing System has a flammability rating of 94V-0.
What materials are used for the FiberRunner 4x4 system?
The channel is made of rigid PVC, and the fittings are made of PC/ABS.
How to Install the FRIDT4X4LBL Spill-Out
This guide provides step-by-step instructions for installing the FRIDT4X4LBL spill-out fitting to corrugated tubing within the Fiberrunner routing system.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers
Supplies needed:
Mounting screws, Terminal connectors
- Select the installation option
Choose between Option A (Fitting to Duct), Option B (Fitting to Fitting), or Option C (Fitting to Fitting) based on your routing requirements.
- Mount the spill-out fitting
Secure the FRIDT4X4LBL spill-out fitting to the designated location using the provided mounting screws. Ensure it is firmly attached and aligned properly.
- Connect the corrugated tubing
Attach the corrugated tubing to the spill-out fitting, ensuring a snug fit to prevent any leaks. Verify that all connections are secure.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.