Contact for Pricing
Overview
- Push-on installation for quick deployment
- Compatible with LD5 and LDPH5 channels
- White finish for visual consistency
- No additional couplers or tools required
- Manufactured in the USA
Specifications
Application | Segregate, Route, and Protect Fiber Optic Cable and Copper Cabling. It is Suited for Data Center Applications where Cable is Routed from Distribution Areas to Equipment Cabinets or Racks. It is Used in Telco Central Offices to Route Fiber Optic Jumper Cab |
Cable Specification | 4 x 4 FiberRunner Fitting |
Color | Black |
Height | 4.63 In. |
Length | 0.75 In. |
Material | ABS |
Material | Poly |
Mounting Type | Push-on |
Series | FiberRunner |
Size | 4X4 |
Special Features | NULL |
Standard | UL Listed to 2024A Optical Fiber Cable Routing Assemblies, Compliant with the applicable tests in Telcordia GR-63-CORE Network Equipment Building Systems Level 3, RoHS Compliant |
Type | End Cap |
Width | 5.38 In. |
Package Dimensions (L x W x H) | 6.1 IN x 5.85 IN x 1.1 IN |
Package Weight (Imperial) | 0.215 lbs |

FREC12X4BL
The FiberRunner End Cap Fitting is used in cable management to close off open ends of the channel or fittings. The FiberRunner End Cap Fitting is a push-on installation and does not require a coupler.Frequently Asked Questions
Is the FiberRunner system UL listed?
Yes, it is UL Listed to 2024A Optical Fiber Cable Routing Assemblies.
What is the minimum bend radius for cables?
The system maintains a minimum bend radius of 2 inches to protect fiber optic cabling.
How does the system facilitate cable access?
The hinged channel cover allows easy access and can stay open between 30° and 90°.
What is the installation time for QuikLock™ Couplers?
QuikLock™ Couplers and Brackets take less than five seconds to connect securely.
How are the components of the system assembled?
Components are assembled using pre-assembled QuikLock™ Couplers, requiring no tools.
What types of cabling does the system support?
The system is designed for fiber optic and high-performance copper cabling.
What applications is the FiberRunner system suited for?
It is suited for data center applications and Telco Central Offices.
What materials are used in the FiberRunner system?
The channel is made of rigid PVC, while the fittings are made of ABS.
Can the system be used in underfloor applications?
Yes, the system can be deployed in approved underfloor applications.
What is the flammability rating of the materials?
The materials have a flammability rating of 94V-0.
How to Install the FREC6X4 End Cap Fitting
This guide provides step-by-step instructions for installing the FREC6X4 End Cap Fitting in a Panduit Fiberrunner routing system.
Estimated time: 30m
Tools needed:
Screwdriver, Wire strippers
Supplies needed:
Mounting screws, End cap fittings
- Prepare the installation area
Ensure that the installation area is clean and free of debris. Verify that the Fiberrunner routing system is properly mounted and accessible.
- Attach the end cap fitting
Align the FREC6X4 end cap fitting with the end of the Fiberrunner system. Secure it in place using the provided mounting screws.
- Verify the installation
Check that the end cap fitting is securely attached and that there are no gaps between the fitting and the Fiberrunner. Ensure that all screws are tightened properly.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.