Contact for Pricing
Minimum Qty: 10
Multiplier: 10
*Contact for lower quantities*
Overview
- Secures cables in channel when cover is not used
- Installable anywhere on the channel
- Placement options: near coupler or every 18" (457mm)
- Designed for 6 x 4 System
- Available in black color only
Specifications
Application | (1)The Fiber-Duct 6X4 Routing Systems are Comprised of Channel, Fittings, and Brackets Designed to Segregate, Route, and Protect Fiber Optic Cable and Copper Cabling. (2) It is Suited for Data Center Applications where Cable is Routed from Distribution A |
Cable Specification | 6 x 4 FiberRunner Channel and Cover |
Color | Black |
Height | 1 In. |
Length | 6.89 In. |
Material | ABS |
Size | 6 x 4 System |
Standard | UL Listed to 2024A,GR-63-CORE,RoHS Compliant |
Type | Cable Retainer |
Width | 1 In. |
Package Dimensions (L x W x H) | 10 IN x 10 IN x 1.5 IN |
Package Weight (Imperial) | 0.417 lbs |

FRCR12BL-X
Cable retainer holds cable in the channel when cover is not used. Install anywhere on channel, near the coupler or every 18 (457mm). Black color only. 12 x 4 System.Frequently Asked Questions
Is the system UL listed?
Yes, the system is UL Listed to 2024A Optical Fiber Cable Routing Assemblies.
What is the minimum bend radius for cables?
The system maintains a minimum bend radius of 2 inches to protect against signal loss.
How do I access cables in the channel?
The hinged channel cover allows easy access and can stay open between 30° and 90°.
What materials are used in the FRCR6BL-X?
The FRCR6BL-X is made from rigid PVC for the channel and ABS for the fittings.
What types of applications is the system suited for?
It is designed for data centers and Telco Central Offices for routing fiber optic and copper cabling.
What safety standards does the system comply with?
It complies with applicable tests in Telcordia GR-63-CORE and Network Equipment Building Systems Level 3.
How are the components of the system assembled?
Components are assembled using pre-assembled Panduit QuikLock Couplers for quick installation.
Can the system be installed under floors?
Yes, the system can be deployed in approved underfloor applications.
What is the maximum cable fill capacity?
The maximum fill capacity varies by cable size; for 1.6mm cables, it's 3819 cables.
What colors are available for the system?
The FiberRunner 6x4 Routing System is available in Yellow and Black.
How to Install the FRHC6OR6 Fiber Runner
This guide provides step-by-step instructions for installing and configuring the FRHC6OR6 Fiber Runner system.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the Fiber Runner
Secure the FRHC6OR6 Fiber Runner to the designated surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the ends of the wires. Connect the wires to the appropriate terminals on the FRHC6OR6, ensuring a secure fit.
- Verify connections
Utilize a multimeter to check the continuity of the connections. Ensure all connections are secure and functioning properly before proceeding.
- Configure the system
Follow the manufacturer's instructions to program the FRHC6OR6 settings according to your specific requirements.
- Calibrate the system
Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance of the Fiber Runner.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.