The Panduit QUICKNET SFQ FQ9N-12-LAU cassette converts a single 12-fiber MPO trunk into six duplex LC/APC connectors for high-density fiber deployments. This Method A cassette uses OS2 singlemode fiber with standard-loss performance, ensuring reliable signal integrity for 10G to 100G Ethernet and Fibre Channel links. The 12-fiber MPO input interfaces with six duplex LC/APC outputs, simplifying polarity management and reducing installation time in data centers, enterprise networks, and central offices. The cassette weighs 2.4 oz (69 g) and measures 5.0 x 128 x 21 mm, fitting standard 1U patch panels and enclosures. Front ports are clearly labeled for quick identification, and the top surface includes a labeling field for asset tracking. The plastic module and composite adapter meet RoHS material restrictions, and the cassette complies with ANSI/TIA-568-C.0 for structured cabling deployments. Compatible with Molex ModLink systems, this cassette supports low insertion loss connections while maintaining front-to-back airflow in hot-aisle/cold-aisle environments.
  • 12-fiber MPO input to six duplex LC/APC outputs
  • OS2 singlemode fiber with standard-loss performance
  • 2.4 oz (69 g) plastic module with composite adapter
  • Front port labeling and top-side asset tagging field
  • Manufactured in the US

Specifications

Color
Black
Connection Type
MPO to 6 Duplex LC/APC
Connector 1 Type*
LC Duplex
Connector 2 Type*
MPO-12 Male
Fiber Type
OS2
Insertion Loss
0.75
Material
Polycarbonate
Material
OS2 Fiber
Series
Quicknet SFQ
Type
Fiber Cassette
Package Dimensions (L x W x H)
7.8 IN x 4.5 IN x 1.5 IN
Package Weight (Imperial)
0.41 lbs
FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL

FDS9N-24-10R

FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC/APC; OS2 FIBER AND STANDARD LOSS; MODIFIED METHOD A - PAIR FLIPPED

FHC9N-12-3GAF

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC/APC; OS2 FIBER AND STANDARD LOSS; MODIFIED METHOD A - PAIR FLIPPED
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM4 FIBER AND OPTIMIZED LOSS; METHOD A POLARITY

FHCZO-12-03AS

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM4 FIBER AND OPTIMIZED LOSS; METHOD A POLARITY
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM3 FIBER AND STANDARD LOSS; METHOD A POLARITY

FHCXN-12-03AS

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM3 FIBER AND STANDARD LOSS; METHOD A POLARITY
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OS2 FIBER AND STANDARD LOSS; UNIVERSAL

FHC9N-12-03U

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OS2 FIBER AND STANDARD LOSS; UNIVERSAL
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM4 FIBER AND OPTIMIZED LOSS; UNIVERSAL

FHCZO-12-03U

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC; OM4 FIBER AND OPTIMIZED LOSS; UNIVERSAL
HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC/APC; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

FHC9N-12-3GAS

HD FLEX CASSETTE; 1 MPO TO 6 DUPLEX SC/APC; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY
QUICKNET SFQ 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

FQ9N-12-LAAS

QUICKNET SFQ 1 MPO TO 6 DUPLEX LC/APC CASSETTE; OS2 FIBER AND STANDARD LOSS; METHOD A POLARITY

Frequently Asked Questions

What is the return loss for different fiber types?

Return loss is >20dB for OM1, >26dB for OM3/OM4, and >55dB for OS1/OS2 fiber types.

What is the connector durability rating?

Connectors meet TIA/EIA-568C.3 A.4.9 and have a durability of 500 mating cycles.

What fiber counts are available?

The cassettes are available with fiber counts of 6, 8, and 12.

What split sleeve materials are used?

Zirconia ceramic is used for OM3, OM4 multimode, and OS1/OS2 singlemode cassettes. Phosphor bronze is used for OM1 multimode cassettes.

What data rates and link lengths do the cassettes support?

Cassettes support 10 Gb/s data rates for link lengths up to 300 meters with OM3 fiber and up to 550 meters with OM4 fiber.

How many fiber connections fit in one rack unit?

High-density cassette patch panels can hold up to 8 cassettes, allowing up to 96 fiber connections in one rack unit (1 RU).

What is the operating temperature range?

The operating temperature range for the cassettes is 0°C to +70°C (32°F to 158°F).

What are the storage and shipping temperatures?

Storage and shipping temperatures range from -40°C to +70°C (-40°F to 158°F).

What is the recommended installation temperature?

The recommended installation temperature range is 0°C to +60°C (32°F to 140°F).

What industry standards do the cassettes comply with?

The cassettes comply with TIA/EIA-568-C.3, IEEE 802.3ae, ANSI T11.2, and ROHS 2002/95/EC standards.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.