Panduit FPONSS1X16 - The in-line, splice-ready fiber optic splitter is a small form factor passive device that fits in FPONE enclosures and uses a planar lightwave circuit to split one signal to sixteen signals for passive optical network applications. The splitter includes one bare fiber input on one side and sixteen bare fiber outputs on the opposite side.
Panduit

FPONSS1X16

UPC: 613056766563


Documents & Media
Technical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Minimum Qty: 10

Multiplier: 1

*Contact for lower quantities*

Overview

The Panduit FPONSS1X16 is a compact, in-line fiber optic splitter designed for Passive Optical Network (PON) applications. This splice-ready passive device utilizes advanced Planar Lightwave Circuit (PLC) technology to efficiently divide a single optical signal into sixteen separate outputs. Engineered for seamless integration within Panduit FPONE enclosures, the FPONSS1X16 offers a robust solution for signal distribution in telecommunications and data networking infrastructure. Its small form factor minimizes space requirements, making it ideal for densely populated network cabinets and distribution points. The splitter features a single bare fiber input on one side, directly connecting to the incoming optical signal. On the opposite side, sixteen bare fiber outputs are provided, each capable of carrying a portion of the original signal. This configuration is essential for expanding network reach and subscriber capacity in fiber-to-the-home (FTTH) and other PON architectures. The bare fiber termination simplifies field installation and splicing, reducing labor time and potential connection losses. Manufactured in the USA, the FPONSS1X16 (SKU: FPONSS1X16) adheres to high-quality standards. Its material composition is Fiber Optic, and the connection type is Bare Fiber, ensuring compatibility with standard fiber optic splicing equipment and connectors. The series is FPONE, indicating its design and compatibility within this specific Panduit product line. This splitter is a critical component for network operators looking to cost-effectively deploy and scale their fiber optic networks. By enabling one input to serve sixteen endpoints, it significantly reduces the need for active optical equipment and associated power consumption, aligning with the passive nature of PON deployments. The FPONSS1X16 is a reliable and efficient choice for signal splitting in modern optical networks.
  • Splits one optical signal into sixteen outputs
  • Utilizes Planar Lightwave Circuit (PLC) technology
  • Compact, in-line, splice-ready passive device
  • Bare fiber input and sixteen bare fiber outputs
  • Designed for Panduit FPONE enclosures

Specifications

Application
Passive Optical LAN
Depth
NA In.
Standard
GR-1209-CORE, GR-1221-CORE
Type
Fiber Optic Splitter
Width
NA In.
Package Dimensions (L x W x H)
7.8 IN x 4.5 IN x 1.5 IN
Package Weight (Imperial)
0.74 lbs
N-Type Front and Rear Cage Nut Equipment Rail Kit for 48 RU Cabinet

N8RCFR

N-Type Front and Rear Cage Nut Equipment Rail Kit for 48 RU Cabinet
Rack Access Kit NetBotz 125

NBHN125S

Rack Access Kit NetBotz 125

Frequently Asked Questions

What is the operating wavelength range for the splitters?

The operating wavelength range for the PLC splitters is 1260-1650nm.

What is the maximum optical power these splitters can handle?

The maximum optical power these PLC splitters can handle is 300 mw.

What is the operating temperature range for the splitters?

The operating temperature range for the PLC splitters is -40°C to +85°C.

What is the storage temperature range for the splitters?

The storage temperature range for the PLC splitters is -40°C to +85°C.

What is the acceptable storage relative humidity?

The acceptable storage relative humidity for the PLC splitters is 20-90% RH.

What is the insertion loss for a 1x16 PLC splitter?

The insertion loss for a 1x16 PLC splitter is 14.2dB. Note that these values do not include connector loss.

What is the IL uniformity for a 1x16 PLC splitter?

The IL uniformity for a 1x16 PLC splitter is 1.5dB.

What is the polarization dependency for a 1x16 PLC splitter?

The polarization dependency for a 1x16 PLC splitter is 0.4dB.

What are the directivity and return loss values?

The directivity is greater than 55dB and the return loss is greater than 55dB.

What are the available configurations for these PLC splitters?

The PLC splitters are available in 1x4, 1x8, 1x16, and 1x32 configurations. They can be bare-fiber or pre-connectorized with SC-APC connectors.

How to Install the FPONSS1X16 Fiber Optic Splitter

This guide provides step-by-step instructions for installing and configuring the FPONSS1X16 Fiber Optic Splitter.

Estimated time: 45m

Tools needed:

Screwdriver, Cable tie tool, Fusion splice equipment

Supplies needed:

Mounting screws, Cable ties, Splice covers, Labels

  1. Mount the splitter housing

    Secure the metallic housing of the FPONSS1X16 splitter in the splice tray above the splice holding slots using a cable tie.

  2. Route the input fiber

    Route the input fiber to the fiber storage spool area, ensuring it is organized and not under tension.

  3. Perform fusion splicing

    Using the fusion splice equipment, splice the input side of the splitter according to the manufacturer's instructions. Cover each splice with a splice cover and mount them in storage trays.

  4. Document and label fiber routing

    Document the fiber routing and label each fiber appropriately for future reference.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.