Contact for Pricing
Overview
- High-density (HD) FLEX LC splice/FAP cassette
- Six duplex LC/APC adapters (12 LC ports total)
- Singlemode fiber optic connectivity
- Green housing for APC connection identification
- Zirconia sleeves for precise adapter alignment
Specifications
Color | Black |
Connection | LC/APC |
Connector 1 Type* | LC Duplex APC |
Fiber Type | OS2 |
Insertion Loss | 0.75 |
Material | Polycarbonate |
Type | Fiber Cassette |
Package Dimensions (L x W x H) | 7.8 IN x 4.5 IN x 1.5 IN |
Package Weight (Imperial) | 0.407 lbs |

FDS9N-24-10R
FlexCore Front Access ODF Fiber Optic Splice Cassette, Singlemode (OS2) 24-fiber LC Duplex to Ribbon Pigtails, Standard IL
FHS9N-12-LAR
HD FLEX LC SPLICE CASSETTE PRELOADED WITH 12 OS2 LC RIBBON (250UM) AND STANDARD IL; 6-PORT DUPLEX LC/APC ADAPTERS WITH ZIRCONIA SLEEVES
FHSN-24
24F HD FLEX, BLANK FRONT, SPLICE-ONLY CASSETTE LOADED WITH PIGTAIL AND RIBBON SPLICE PROTECTORS
FHC9N-24-LAAF
HD FLEX CASSETTE; 2 MPO TO 12 DUPLEX LC/APC; OS2 FIBER AND STANDARD LOSS; MODIFIED METHOD A - PAIR FLIPPEDFrequently Asked Questions
What fiber types do HD Flex cassettes support?
HD Flex Fiber Optic Cassettes support multimode fiber types OM3, OM4, and OM4+ Sig Core, as well as singlemode fiber type OS2.
What are the operating temperature limits for these cassettes?
The operating temperature range for HD Flex Fiber Optic Cassettes is 0°C to 70°C (32°F to 158°F).
What front and rear connectors are available?
Front connectivity options include LC, LC/APC Duplex, SC, SC/APC Duplex, and MPO Adapters. Rear connectivity uses MPO Adapters or 12/24-fiber for splicing.
What is the connector durability of the cassettes?
The connectors meet ANSI/TIA-586C.3 and have a durability of 500 mating cycles.
What are the insertion loss values for multimode cassettes?
Multimode optimized cassettes have 0.5dB insertion loss, while ultra low loss versions have 0.35dB. Splice cassettes have 0.15dB or 0.10dB plus splice loss.
What are the insertion loss values for singlemode cassettes?
Singlemode standard cassettes have 0.75dB insertion loss, and the 24F MPO cassette has 1.2dB. Splice cassettes have 0.35dB plus splice loss.
What return loss can be expected for LC and LC/APC connectors?
Multimode LC connectors have >26dB return loss. Singlemode LC connectors have >55dB, and LC/APC connectors have >65dB.
What networks do HD Flex Fiber Optic Cassettes support?
HD Flex Fiber Optic Cassettes offer deployment options to support both Ethernet and Fibre Channel networks.
What configurations are available for HD Flex cassettes?
Cassettes are available in 4-port, 6-port, and 12-port configurations. Splice cassettes and adapter/coupler modules are also offered.
What standards do these fiber optic cassettes meet?
The cassettes meet or exceed ISO/IEC 11801, ANSI/TIA-568-C.3, TIA-604-5 (FOCIS-5), TIA-604-10 (FOCIS-10), and are RoHS Compliant.
How to Install the FHS9N-12-LAN HD Flex LC Splice Cassette and Fiber Adapter Panel (FAP)
Installation guide for mounting and wiring the FHS9N-12-LAN HD Flex LC Splice Cassette and Fiber Adapter Panel (FAP).
Estimated time: 30m
Tools needed:
Screwdriver, Lint-free tissue, Isopropyl alcohol
Supplies needed:
Pan-Ty Cable Ties, Splice sleeves
- Prepare the incoming field cable
Strip the outer jacket of the incoming field cable by 20 inches. Secure the cable with Pan-Ty Cable Ties and Kevlar with a screw if applicable. The maximum cable diameter is 7.4mm.
- Prepare fibers for splicing
Expose all fiber ends for splicing. Slide a splice sleeve onto either the pigtail or field fiber. Strip approximately 35mm of coating from each fiber. Wipe the bare fiber with a lint-free tissue soaked with isopropyl alcohol. Cleave the fiber so that 10mm of bare fiber extends past the fiber coating.
- Splice and route fibers
Splice all fibers and heat the splice sleeve(s) according to the splicer manufacturer's instructions. Route the spliced fibers into the cassette, ensuring they are located under the routing tabs. Secure the splice sleeves within the splice organizer.
- Install patch cords and close cassette
Remove the cover and internal dust caps from the cassette. Install patch cords and route cables as shown in Figure 2. Re-install the cover.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.