Authorized Panduit Distributor
Panduit FDCZA-24-10B2LH - 24F Front Access Cassette, OM4 LC Duplex to 2 x MPO12, Method B2, Ultra IL. LH
Panduit

FDCZA-24-10B2LH

UPC: 613056852365


Documents & Media
Technical DrawingFull Engineering DrawingSpecification SheetVideo Clip

Contact for Pricing

Overview

The Panduit FDCZA-24-10B2LH is a 24-fiber front-access cassette designed for high-density data center connectivity. This cassette facilitates the conversion of OM4 LC duplex connections to two MPO12 connectors, utilizing Method B2 polarity for consistent signal routing. It features Ultra Low Insertion Loss (Ultra IL) to minimize signal degradation and low polarization-dependent loss (LH) for stable performance across various wavelengths. The front-access design enhances port management and reduces cable congestion within high-density racks. Compatible with OM4 multimode fiber, this cassette supports 10G, 40G, and 100G Ethernet applications, accommodating up to 12 fiber strands per MPO12 connector. Housed in a durable metal enclosure, it ensures reliable operation in demanding data center and enterprise network environments. The FDCZA-24-10B2LH is ideal for migration paths to higher speeds, offering backward compatibility with existing LC-based systems while enabling scalable MPO-based infrastructure. Manufacturer: Panduit. SKU: FDCZA-24-10B2LH. UNSPSC Code: 43223310. Country of Origin: US.
  • 24-fiber front-access cassette for high-density data centers
  • Converts OM4 LC duplex to two MPO12 connectors
  • Method B2 polarity for consistent signal routing
  • Ultra Low Insertion Loss (Ultra IL) for minimal signal degradation
  • Low Polarization-Dependent Loss (LH) for stable performance

Specifications

Color
Black
Connection
MPO
Connection Type
LC Duplex to MPO12
Connection Type
OM4 LC Duplex to MPO12
Connector 1 Type*
LC Duplex
Connector 2 Type*
MPO-12 Male
Fiber Type
OM4
Insertion Loss
NA
Material
Metal
Material
Polycarbonate
Mounting Type
Front access
Series
FDCZA
Type
Fiber Cassette
Package Dimensions (L x W x H)
9.9 IN x 13 IN x 1.3 IN
Package Weight (Imperial)
0.81 lbs
OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Optimized Insertion Loss, No pulling Eye - 15 Meters

FZUYBXRNNONM015

OM4 Multi Mode 24 Fiber Indoor Small Diameter Trunk, Euroclass B2ca, FlexCore Front Access ODF LC Cassette, Right side Blunt end, Optimized Insertion Loss, No pulling Eye - 15 Meters
24F Front Access Cassette, OM5 LC Duplex to 2 x MPO12, Method B2, Ultra IL. LH

FDCWA-24-10B2LH

24F Front Access Cassette, OM5 LC Duplex to 2 x MPO12, Method B2, Ultra IL. LH
OM4 HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal

FHC3ZA-24H-10U

OM4 HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal
24F Front Access Cassette, Sig Core OM4+ LC Duplex to 2 x MPO12, Method B1, Ultra IL. RH

FDCSA-24-10B1RH

24F Front Access Cassette, Sig Core OM4+ LC Duplex to 2 x MPO12, Method B1, Ultra IL. RH
OS2 HD Flex Cassette, 6-Port, 4-to-1 Conversion Cassette, Optimized IL, Universal-2

FHC39O-08-10U2

OS2 HD Flex Cassette, 6-Port, 4-to-1 Conversion Cassette, Optimized IL, Universal-2
OM4+ HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal-2

FHC3SA-24H-10U2

OM4+ HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal-2
24F Front Access Cassette, Sig Core OM4+ LC Duplex to 2 x MPO12, Method A Flipped, Ultra IL. RH

FDCSA-24-10AFRH

24F Front Access Cassette, Sig Core OM4+ LC Duplex to 2 x MPO12, Method A Flipped, Ultra IL. RH
OM5 HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal-2

FHC3WA-24H-10U2

OM5 HD Flex Cassette, 12-Port, 4-to-1 Conversion Cassette, Ultra IL, Universal-2

Frequently Asked Questions

What is the operating temperature range?

The operating temperature range is 0°C to 70°C (32°F to 158°F).

Are the cassettes compatible with FlexCore™ frames?

Yes, the cassettes are designed for use within the FlexCore™ Optical Distribution and Splice Frame.

What fiber types are supported by the cassettes?

The cassettes support multimode fibers (OM4, OM5, OM4+ Sig Core) and singlemode fibers (OS2).

What is the installation temperature requirement?

The installation temperature should be between 0°C and 60°C (32°F to 140°F).

What is the connector durability rating?

Connectors meet ANSI/TIA-586C.3 standards and have a durability of 500 mating cycles.

What are the storage temperature limits?

The storage and shipping temperature range is -40°C to 70°C (-40°F to 158°F).

What safety standards do the cassettes meet?

The cassettes meet or exceed ISO/IEC 11801 and ANSI/TIA-568-C.3 standards.

What is the maximum insertion loss for multimode cassettes?

The maximum insertion loss for optimized multimode MPO-LC cassettes is 0.5dB.

What is the maximum cable outer diameter?

The maximum cable outer diameter for the cassettes is 8mm.

What types of cassettes are available?

Available types include MPO-LC, splice, and tethered cassettes with various configurations.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.