Authorized Panduit Distributor
Panduit F8RNM5ENNAAM010 - OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Pigtail, Method A Polarity, Std IL, Pulling Eye on one end, 10 Meters
Panduit

F8RNM5ENNAAM010

UPC: 613056859371


Documents & Media
Technical DrawingFull Engineering DrawingSpecification Sheet

Contact for Pricing

Overview

The Panduit F8RNM5ENNAAM010 is a high-density OS2 Singlemode 864-fiber trunk cable, 10 meters in length, designed for data center and enterprise backbone applications. This cable features a Riser-rated LSZH (Low Smoke Zero Halogen) jacket, compliant with Cca fire safety standards, making it suitable for vertical riser installations. The termination on one end consists of a female MPO connector, and the other end is terminated with individual pigtail connectors, allowing for direct splicing to patch panels or network equipment. The Method A polarity configuration ensures consistent signal routing between the MPO connector and the pigtails. This trunk cable offers standard insertion loss, supporting high-speed data transmission for applications like 100G, 400G, and beyond within structured cabling systems. An integrated pulling eye on the MPO end facilitates easier installation in confined conduit or cable tray environments. The F8RNM5ENNAAM010 is compatible with Panduit and third-party MPO-based systems and adheres to TIA-568 and ISO/IEC standards for optical fiber cabling.
  • OS2 Singlemode 864-fiber count
  • 10-meter cable length
  • Riser-rated LSZH (Cca compliant) jacket
  • Female MPO to individual pigtail termination
  • Method A polarity for consistent signal routing

Specifications

Application
OS2
Color
Yellow
Connection Type
MPO Female to Pigtail
Connector 1 Type*
MPO-12 Female
Connector 2 Type*
Unterminated
Fiber Count*
864
Material
LSZH
Material
LSZH (Low Smoke Zero Halogen)
Poles
864
Series
Panduit OS2 Singlemode
Size
864-fiber
Special Features
Indoor/Outdoor
Temperature Rating
NA F
Type
Trunk Cable Assembly
Package Dimensions (L x W x H)
44 IN x 44 IN x 50 IN
Package Weight (Imperial)
162.56 lbs
Singlemode (OS2) 576-fiber I/O LSZH Riser Euroclass Cca Female MTP to Pigtail Trunk, Method A, Standard IL, 30 meter

F8ONM5ENNAAM030

Singlemode (OS2) 576-fiber I/O LSZH Riser Euroclass Cca Female MTP to Pigtail Trunk, Method A, Standard IL, 30 meter
OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Female MPO, Method A Polarity, Std IL, Pulling Eye on one end, 10 Meters

F8RNM5E5EAAM010

OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Female MPO, Method A Polarity, Std IL, Pulling Eye on one end, 10 Meters
OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Pigtail, Method A Polarity, Std IL, Pulling Eye on one end, 100 Meters

F8RNM5ENNAAM100

OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Pigtail, Method A Polarity, Std IL, Pulling Eye on one end, 100 Meters
OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Pigtail, Method A Polarity, Std IL, Pulling Eye on one end, 30 Meters

F8RNM5ENNAAM030

OS2 Singlemode 864-fiber I/O, Riser, LSZH, Cca Trunk, Female MPO to Pigtail, Method A Polarity, Std IL, Pulling Eye on one end, 30 Meters
The 6 fiber outside plant non-armored cable is OM3, non-rated and features 250µm fibers.

FLTNX06

The 6 fiber outside plant non-armored cable is OM3, non-rated and features 250µm fibers.
Clamp, Cable, 1/2 NPT, Atkinson

K150159A

Clamp, Cable, 1/2 NPT, Atkinson
OM3 HD FLEX CASSETTE, 4-PORT, 4-TO-1 CONVERSION CASSETTE, OPTIMIZED, METHOD A

FHC3XO-08H-10A

OM3 HD FLEX CASSETTE, 4-PORT, 4-TO-1 CONVERSION CASSETTE, OPTIMIZED, METHOD A
OM4 HD FLEX CASSETTE, 12-PORT DUPLEX LC TO (2) 12-FIBER MPOS, ULTRA LOW LOSS, METHOD B

FHCZA-24-10BN

OM4 HD FLEX CASSETTE, 12-PORT DUPLEX LC TO (2) 12-FIBER MPOS, ULTRA LOW LOSS, METHOD B

Frequently Asked Questions

What are the primary applications for this cable?

This cable consolidates multiple MPO-12 fiber connectors to reduce congestion and optimize cable management in large and hyperscale datacenters.

What type of fiber and cable jacket does it have?

It uses OS2 9/125μm Singlemode fiber with an Indoor/Outdoor Bend Insensitive Rollable Ribbon cable type. The jacket is Multi Rated Riser, LSZH, and Euroclass Cca.

What connector types are available for this cable?

End 'A' can have 12F-MPO APC Female or Male connectors. End 'B' can have 12F-MPO APC Female or Male, or Pigtail connectors.

What fiber counts are available for these assemblies?

The assemblies are available with fiber counts of 144, 288, 432, 576, and 864.

What is the maximum cable attenuation?

Maximum cable attenuation for Singlemode is 0.4dB/km at 1310nm and 0.3dB/km at 1550nm.

What is the maximum connector insertion loss?

The maximum connector insertion loss for Standard Singlemode MPO is 0.75dB.

What is the operating temperature range?

The operating temperature range is -20°C to +70°C (-4°F to 158°F).

What is the recommended installation temperature range?

The recommended installation temperature range is -10°C to +60°C (14°F to 140°F).

What is the cable tensile strength?

The cable tensile strength is 2670 N (600 lbs.).

How many mating cycles can the connectors withstand?

The connectors have a durability of 500 mating cycles, provided proper cleaning and inspecting are performed.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.