Panduit F8BNM9RBNSAF150 - FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 150 Feet
Panduit

F8BNM9RBNSAF150

UPC: 613056871717


Documents & Media
BrochureTechnical DrawingFull Engineering DrawingInstallation InstructionsSpecification Sheet

Contact for Pricing

Overview

The Panduit F8BNM9RBNSAF150 FlexCore Tethered Fiber Optic Enclosure provides a pre-terminated, high-density OS2 singlemode fiber solution with 288 fibers in a rollable ribbon trunk. This enclosure features right-side cable entry, multi-rated I/O riser compliance, and a Euroclass Cca LSZH jacket for enhanced safety in indoor environments. The pre-terminated duplex LC cassettes ensure straight-through polarity with standard insertion loss, eliminating on-site termination and reducing installation time. Designed for backbone and distribution applications, the 150-foot trunk length provides flexibility in routing while maintaining signal integrity. The enclosure supports multi-rated I/O riser compliance, making it suitable for commercial and industrial deployments where fire safety and performance are critical. Ideal for data centers, enterprise networks, and campus environments requiring scalable, low-loss fiber connectivity.
  • 288-fiber OS2 singlemode pre-terminated rollable ribbon trunk
  • Right-side cable entry with multi-rated I/O riser compliance
  • Euroclass Cca LSZH jacket for indoor fire safety
  • Pre-terminated duplex LC cassettes with straight-through polarity
  • 150-foot trunk length for flexible routing in backbone applications

Specifications

Separated compartments
NA
Package Dimensions (L x W x H)
30.4 IN x 12.9 IN x 31.1 IN
Package Weight (Imperial)
68.16 lbs
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity

F8BNMMRBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 200 Feet

F8BNM9LBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 200 Feet
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity

F8BNMMLBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 200 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity

F8BNM9RBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity
The Opticom Pre-loaded Fiber Tray includes 24 ST adapters with zirconia split sleeves. The tray is 1 RU and is 1.75 inches h x 8.01 inches d x 19.0 inches w (44.0mm x 203.4mm x 483.0mm).

FT1W24ST

The Opticom Pre-loaded Fiber Tray includes 24 ST adapters with zirconia split sleeves. The tray is 1 RU and is 1.75 inches h x 8.01 inches d x 19.0 inches w (44.0mm x 203.4mm x 483.0mm).
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 150 Feet Through Polarity

F8BNMMRBNSAF150

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 150 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 200 Feet

F8BNM9RBNSAF200

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 200 Feet
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 150 Feet

F8BNM9LBNSAF150

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC Cassettes, Standard Insertion Loss, Straight Through Polarity - 150 Feet
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

F8BNMMRBNSAF100

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity

F8BNMMRBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Right cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 50 Feet Through Polarity
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion, Loss, Straight Through Polarity- 50 Feet

F8BNMMLBNSAF050

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion, Loss, Straight Through Polarity- 50 Feet
FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

F8BNMMLBNSAF100

FlexCore Tethered Fiber Optic Enclosure with Left cable entry, Singlemode OS2 288 Fiber Rollable Ribbon Trunk, Multi Rated I/O Riser, LSZH, Euroclass Cca Jacket, Pre-Terminated to Duplex LC/APC Cassettes, Standard Insertion Loss, Straight - 100 Feet Through Polarity

Frequently Asked Questions

What is the Panduit FDUSP6 product?

The Panduit FDUSP6 is an ODF Spool available as a 6-pack with labels.

What does the FDUSP6 kit include?

The FDUSP6 kit includes six ODF spools and corresponding enclosure door labels for 11 x 4 RU enclosures.

How many FDUSP6 kits are needed for a single FlexCore frame?

One FDUSP6 Spool Kit (x6) is required for a single FlexCore 600mm frame configuration.

How many FDUSP6 kits are needed for a double FlexCore frame?

Two FDUSP6 Spool Kits (x6) are required for a double FlexCore 600mm compact cross connect frame.

What is the primary function of the FDUSP6 Spool Kit?

The FDUSP6 Spool Kit is a component of the FlexCore ODF's tool-free adjustable spool system, designed to optimize pathway space.

How to Install the FlexCore ODF Front Access 288 Fiber Tethered Universal Enclosure

This guide provides step-by-step instructions for installing the FlexCore ODF Front Access 288 Fiber Tethered Universal Enclosure, ensuring proper mounting and cable management.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Prepare the enclosure

    Open the box carefully to avoid cutting the cable. Remove all foam and packaging materials to access the enclosure and cable.

  2. Mount the enclosure

    Install the enclosure into the frame using the methods outlined in FS203. Ensure it is securely attached and level.

  3. Connect the cable

    Attach the cable transition to the ingress/egress plates on the 150mm vertical cable manager as specified in FS206, Section 4.

  4. Verify cable slack

    Pull out every tray in the enclosure to ensure there is enough slack for the tray to move without putting extra stress on the fibers.

  5. Complete installation

    Ensure all connections are secure and that the installation is complete as per the guidelines. Inspect individual cassettes if necessary.

Frequently Asked Questions about Panduit

What environmental ratings do Panduit products have?

Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.

What certifications and standards do Panduit products comply with?

Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.

What industries and applications are Panduit products used for?

Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.

What are the main product lines offered by Panduit?

Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.

What are the key features of Panduit products?

Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.

What is Panduit's warranty policy?

Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.

What technical support does Panduit offer?

Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.

What accessories are available for Panduit products?

Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.

How are Panduit products typically installed?

Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.