Panduit E42D02L EL2P MI PDU, 100/125 AMP, (21)C13/C15, (21)C13/C15/C19/C21, IEC 60309 3P+N+E 6h…
UPC: 613056916524
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 100/125A input via IEC 60309 3P+N+E 6h 100A/125A connector
- (21) C13/C15 outlets plus (21) C13/C15/C19/C21 outlets for flexible equipment compatibility
- 3-meter cable length for installation flexibility
- Black finish with corrosion-resistant properties
- 3-meter cable length for flexible placement
Specifications
Color | Black |
Connection Type | IEC 60309 |
Connection Type | IEC 60309 3P+N+E 6h |
Current Rating | 100/125 A |
IP Rating | IP67 |
Poles | 3P+N+E |
Series | EL2P MI |
Series | EL2P MI PDU |
Package Dimensions (L x W x H) | 78 IN x 10 IN x 5 IN |
Package Dimensions (L x W x H) | 198.12 cm x 25.4 cm x 12.7 cm |
Package Weight (Imperial) | 49.0000 L |
Package Weight (Metric) | 22.2264 kg |

ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.
UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.Frequently Asked Questions
What is the amperage rating of this Panduit PDU?
This Panduit EL2P MI PDU has a current rating of 100/125 AMP.
How many C13 and C19 outlets does this PDU have?
The PDU features (21) C13/C15 outlets and an additional (21) C13/C15/C19/C21 outlets, totaling 42 outlets.
What type of input connector does the PDU use?
The PDU uses an IEC 60309 3P+N+E 6h connector rated for 100A/125A.
Is this PDU suitable for wet environments?
Yes, the PDU has an IP67 rating, providing protection against dust and water ingress.
How to Install a Panduit EL2P Power Distribution Unit (PDU)
This guide provides step-by-step instructions for qualified personnel to safely install a Panduit EL2P Rack Power Distribution Unit (PDU) into a datacenter rack or cabinet, covering mounting, grounding, and power connection procedures for both vertical and horizontal models.
Estimated time: 1h
Tools needed:
#2 Phillips screwdriver, T10 Torx screwdriver, T20 Torx screwdriver, 2.5mm hex key Allen wrench
Supplies needed:
Mounting hardware (screws, cage nuts, brackets as applicable), Ground bonding cable, Star washer
- Review Safety Information and Prepare
Before beginning, carefully read all safety information in the PDU manual. Ensure the installation environment is temperature and humidity controlled, free of conductive contaminants. Verify that all circuit breakers are in the off position before connecting input power. Confirm that the PDU is intended for Information Technology Equipment (ITE) loads with linear/Power Factor Corrected (PFC) input current. Ensure you have a reliable grounded connection available. WARNING: This PDU contains LETHAL VOLTAGES. Installation must be performed by individuals knowledgeable about AC power products.
- Mount the PDU in the Rack
Secure the PDU within the datacenter rack. For vertical PDUs, insert the pre-installed mounting buttons into the keyhole slots on the rack's PDU mounting bracket and tighten with a #2 Phillips screwdriver to 3.0Nm. For horizontal 1U/2U PDUs, install cage nuts at the desired U-locations on the RETMA rails. Then, attach the PDU's mounting bracket ears to the rails using screws. For high-power horizontal PDUs, also secure front mounting brackets to the PDU chassis with a 2.5mm hex key Allen wrench.
- Ground the PDU Chassis
Connect a ground bonding cable from the external ground bonding point on the PDU chassis to a known earthed reference terminal in the building or the rack's grounding strip/bus bar. Ensure conductor sizes meet National or Local Electrical Codes (e.g., NEC Table 250.122). This provides supplementary Earth bonding to the rack metalwork. HIGH LEAKAGE CURRENT. Ensure a reliable grounded (earthed) connection.
- Connect the PDU to a Power Source
Ensure the feed circuit breaker for the power source is OFF. Verify all circuit breakers on the PDU are set to ON. Connect the PDU's input power cord to an appropriately rated, grounded branch circuit, adhering to all local and national electrical codes. Refer to the compliance label on the PDU for input ratings. Once connected, turn the feed circuit breaker ON and wait for the operating system to load.
- Rotate or Replace Network Controller (Optional)
If desired, rotate or replace the network control module. Use a T10 Torx screwdriver to remove the two retaining screws. If rotating, disconnect the ribbon cable to prevent damage, rotate the controller, and carefully reconnect the ribbon cable. If replacing, disconnect the old ribbon cable, connect the new ribbon cable to the new controller, and mate it to the PDU chassis. Reinstall and torque the two screws to 2.2–3.1 lbf-in [0.25–0.35 N-M]. WARNING: Overtightening may cause metal deformation.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.