Panduit CUSREFRT9W1 The Net-Contain End of Row Frame is part of the Universal Single Row Containment system.…
UPC: 074983082469
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Part of the Universal Single Row Containment system
- Compatible with 48 and 52 RU cabinets
- Designed for a 40.5-inch (1030mm) aisle width
- White finish for clean integration
- Enhances data center thermal management
Specifications
Application | Universal Single Row Containment System will be able to retrofit in a Brownfield (existing Data Center) or Greenfield (new Data Center) application that uses non-Panduit cabinets. |
Color | White |
Material | Steel |
Series | Net-Contain Universal Single Row Containment |
Size | 48-52 RU |
Standard | RoHS Compliant |
Type | End of Row Frame |
Width | 59.83 in |
Width | 1519.682 mm |
Package Dimensions (L x W x H) | 97 IN x 40 IN x 7.75 IN |
Package Weight (Imperial) | 143 lbs |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What are Net-Access N-Type Cabinets designed for?
Net-Access N-Type Cabinets are designed for high-density network, storage, and compute applications requiring optimal thermal management and high cable density capacity.
How do the leveling feet simplify installation?
Heavy duty, M14 thread top drive leveling feet are easily accessed, reducing cabinet leveling time by up to 80% compared to typical leveling feet.
How is the N-Type cabinet grounded?
The entire N-Type cabinet is fully electrically bonded, requiring only a single connection to the grounding infrastructure. No grounding whips are needed for doors or side panels.
What are the load ratings for N-Type cabinets?
Net-Access N-Type cabinets have a static load rating of 3000 lbs. and a rolling load rating of 2500 lbs.
What is the purpose of the Dynamic Cabinet?
The Net-Access Dynamic Cabinet is designed for pre-installation of equipment at one facility and safe shipment to another location, ideal for system integrators.
What is the dynamic shipping load capacity?
The Net-Access Dynamic Cabinet has a dynamic shipping load capacity of 907kg (2,000 lbs.).
What are the available sizes and colors for S-Type cabinets?
S-Type cabinets are available in 600mm, 700mm, 800mm widths; 1070mm, 1200mm depths; 42 RU, 45 RU, 48 RU heights; and black or white colors.
What are the load ratings for S-Type cabinets?
Net-Access S-Type cabinets have a static load rating of 1,364kg (3,000 lbs.) and a rolling load rating of 1,136kg (2,500 lbs.).
What is the installation cost benefit of the top cable routing system?
When integrated into the cabinet, the Net-Access™ Integral Cabinet Top Cable Routing System can reduce installation costs by up to 30%.
What heat loads do Vertical Exhaust Ducts support?
Net-Contain Vertical Exhaust Duct (VED) Systems support high-density heat loads of 30kW or greater per cabinet, optimizing cooling energy utilization.
How to Install the CUSREFRT9W1 Universal Aisle Containment
This guide provides step-by-step instructions for installing the CUSREFRT9W1 Universal Aisle Containment system, including end of row frames, wall beams, and roofing components.
Estimated time: 2h
Tools needed:
Hex wrench, Drill, Measuring tape, Level
Supplies needed:
M6 x 1 x 70mm Hex Head Bolts, M6 Nuts, M5x10mm Hex Head Screws, Support Plates
- Attach Post Extensions and Supports
For 42RU or 48RU setups, attach the Post Extension LH and Post Extension RH to the Left and Right Posts using M6 x 12mm Bolts. For 45RU or 52RU setups, use M6 x 12mm Bolts and include the appropriate spacers (45 Spacer or 52 Spacer). Secure each support with M6 Nuts.
- Prepare for Floor Attachment
Determine the containment system layout and mark the post locations. Drill nine 8mm (5/16") clearance holes in the floor for each post, following the provided layout diagrams for 1200mm or 1800mm aisles.
- Attach Posts to Floor
Position a post over the pilot holes. Insert six M6 x 1 x 50mm hex head bolts through the post feet. From underneath the floor, slide a Support Plate over the bolts and secure with six M6 nuts. Repeat for the second post.
- Install Post Foot Covers
Slide the foot covers onto the base of each post. Secure the foot covers using two M5x10mm hex head screws per cover. If grounding is required, complete it before installing the foot covers.
- Install End of Row Beams
Attach the End of Row Beam to the posts. For 52RU setups, also attach the Transom with Panel. For 48RU setups, attach the Transom with Panel. For 42RU and 45RU setups, attach the Transom separately. Ensure all components are securely fastened according to the specific setup requirements.
- Install Wall Beams
Align the Wall Beams with the installed End of Row Frames. Attach the Wall Beam Connector and Wall Beam Ganging Bracket as needed. Secure the Wall Beams using the appropriate hardware, ensuring they are level and properly supported.
- Install Roofing Components (If Applicable)
For roofing containment, install the Aisle Containment Roofing Aisle Beam and secure it. Place and secure the Roof Panel onto the beam. Refer to the specific instructions for 600mm, 700mm, or 800mm roofing sections.
- Install Vertical Wall Components (If Applicable)
Install the Vertical Wall Brace or Vertical Wall Adapter. Attach the Wall Brace to the Vertical Wall. Apply foam seals as directed. Install the Vertical Wall, setting the panel height and attaching seals to ensure proper closure.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.