Panduit CUSR1SDLHS1 The Net-Contain Single Sliding Door is part of the Universal Single Row Containment…
UPC: 074983082988
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Part of the Net-Contain Universal Single Row Containment System
- Designed for 3-foot (900mm) aisle widths
- Features a left-hand opening for convenient access
- Durable silver finish for a professional look
- Optimizes data center airflow and cooling efficiency
Specifications
Color | Silver |
Standard | RoHS Compliant |
Type | Single Sliding Door |
Width | 48 in |
Width | 1219.2 mm |
Package Dimensions (L x W x H) | 96.25 IN x 30 IN x 70 IN |
Package Weight (Imperial) | 390 lbs |

UTP6AL1MBU
The TX6A™ 10Gig Cat 6A UTP Patch Cord is a 1-Meter, Blue cord constructed of 24 AWG, unshielded, twisted pair stranded, LSZH (60332-1) cable with high-performance modular plugs. Its MaTriX Tape Technology limits alien crosstalk, ensuring 10 Gb/s transmission. The tangle-free latch prevents snags and ensures a fast release, streamlining moves, adds, and changes. Enabled with RapidID, the product has pre-installed barcodes for simple port mapping using RapidID software.
CPP24FMWBLY
The Mini-Com Flush Mount Modular Patch Panel accepts up to 24 Mini-Com Modules for unshielded applications in 1 RU, and mounts to 19 inch and 23 inch racks and cabinets. The panel mounts flush with the rack and can be identified with adhesive labels and is black.
3085
Super-Safeway® Multiple Outlet Box, Extended Depth, 2-Sided, F2 (1/2") Cord Grip Body, with Flip Lids for (2) Duplex Not Included
ST4803PDGM
Surge-Trap® Surge Protective Device is a no-fuse surge suppressor. The Surge-Trap is a UL 1449 Third Edition compliant modular style surge protective device that is DIN-rail mountable featuring a fail-safe self-protected design, visual indicator and a small foot print. A remote indicator option provides status to critical control circuit. The Surge-Trap provides advanced overvoltage protection utilizing Mersen's patented TPMOV® technology without additional protection devices. 480 Volts 3P Delta system type without N-G mode, with microswitch .
F62ERLNSNSNM002
OM1 2 fiber, 16mm jacket, patchcord, Riser (OFNR) rated, LC duplex to SC duplex, Std IL
CESUM3-C15
Membrane plate cable entry system offers a good strain relief while maintaining IP/NEMA ingress sealing rating. The CESUM3-C15 is a Rectangular Un-Terminated Cable Entry System, 4.1" (103 mm) Long, with 8 Openings 0.12" (3.0 mm) to 0.31" (8 mm), 3 Openings 0.20" (5.1 mm) to 0.35" (9.0 mm), 4 Openings 0.3" (7.5 mm) to 0.47" (12.0 mm). Color is Black. Standard Package Quantity is 1 PC.Frequently Asked Questions
What is the dynamic shipping load for Net-Access Dynamic Cabinets?
Net-Access Dynamic Cabinets have a dynamic shipping load of 907kg (2,000 lbs.), allowing them to be shipped with equipment.
How is the cabinet bonded to the grounding infrastructure?
The entire cabinet is fully electrically bonded, requiring only a single connection to the telecommunications grounding infrastructure, without grounding whips to doors or side panels.
What cooling capacity can Vertical Exhaust Ducts support?
Net-Contain Vertical Exhaust Duct Systems optimize cooling energy utilization to support high density heat loads of 30kw or greater per cabinet.
How do Vertical Exhaust Ducts improve cooling efficiency?
VEDs passively separate hot exhaust air from cooling air, directing it to the CRAH air return system, which improves CRAH and heat exchanger system efficiency up to 40% or more.
What type of equipment rails do N-Type cabinets use?
Net-Access N-Type cabinets come with standard #12-24 tapped equipment rails and adjustable rear rails.
What type of equipment rails do S-Type cabinets use?
Net-Access S-Type cabinets include cage nut rails and adjustable rear equipment rails. S-Type Universal cabinets have adjustable front and rear cage nut rails.
What products are compatible with Net-Contain Cabinet Supported Containment?
This integrated system is compatible with Net-Access N-Type and S-Type Cabinets, FiberRunner®, and Wyr-Grid® Overhead Cable Routing Systems.
What is the load rating for Net-Access cabinet shelves?
Net-Access cabinet shelves (RSHLF23 and RSHLF) have a load rating of 275 lbs.
What are the available dimensions for S-Type cabinets?
S-Type cabinets are offered in 600mm, 700mm, 800mm widths; 1070mm, 1200mm depths; and 42 RU, 45 RU, 48 RU heights.
Can Net-Access Dynamic Cabinets be shipped with equipment?
Yes, the heavy-duty reinforced frame and shock pallet allow the cabinet to be safely shipped with pre-installed equipment.
How to Install the CUSR1SDLHS1 Net-Contain Universal Single Row Containment System
Installation guide for mounting and securing the CUSR1SDLHS1 Net-Contain Universal Single Row Containment System components.
Estimated time: 1h
Tools needed:
Screwdriver, Hex wrench, Drill
Supplies needed:
Mounting screws, Floor anchors, Level
- Prepare the floor layout
Determine the floor layout for the containment system. Ensure all components will be placed in 100mm increments. Mark the drill locations for the post supports according to the provided diagrams, ensuring a minimum distance of 1028mm [40.5"] between the front of the cabinet and the frame.
- Attach foot bases to the floor
Secure the Wall Side Post Foot and Cabinet Side Post Foot to the floor using the appropriate hardware (M6 x 1 x 70mm bolts and M6 serrated flange hex nuts). Ensure the Post Base is also securely fastened on the cabinet side.
- Attach the cabinet side post
Mount the Cabinet Side Post onto the Cabinet Side Post Foot. Secure it using two M6 x 12mm Hex Head SF Screws and two M6 Serrated Flange Hex Nuts.
- Attach the wall side post
Mount the Wall Side Post onto the Wall Side Post Foot. Secure it using four M6 x 12mm Hex Head SF Screws and four M6 Serrated Flange Hex Nuts. Ensure the tab on the Post Foot is oriented correctly.
- Attach door bracket frames
Attach the frame portion of the door brackets to the cabinet side and wall side posts using M6 Serrated Flange Hex Nuts. Ensure the cabinet side bracket with slots and the wall side bracket with threaded holes are correctly positioned.
- Install hangers and supports
Attach the Left Hand Hanger, Right Hand Hanger, and Supports to the posts using M6 x 12mm Hex Head SF Screws and M6 Serrated Flange Hex Nuts. The specific components may vary based on the RU height (e.g., 42RU, 45RU, 48RU, 52RU).
- Install post extensions and spacers (if applicable)
For 48RU and 52RU installations, attach the Post Extensions and Supports. For 52RU installations, also attach the 52 Spacers using M6 x 12mm Hex Head SF Screws and M6 Serrated Flange Hex Nuts.
- Attach single row end beams
Secure the appropriate Single Row End Beam (for 42RU/45RU or 48RU/52RU) to the posts using M6 Serrated Flange Hex Nuts.
- Install post seals
Assemble and attach the Post Seals to the posts using M5 x 0.8mm Hex Head Trilobular Screws. Trim the Flap Seal if necessary and install it onto the Post Seal. Select the appropriate location for the Post Seal based on panel placement (No Panel, 1150 Panel, or 1200 Panel).
- Attach post foot covers
Secure the Post Foot Covers to the cabinet side and wall side posts using M5 x 0.8mm Hex Head Trilobular Screws.
Frequently Asked Questions about Panduit
What environmental ratings do Panduit products have?
Panduit products feature comprehensive environmental ratings across multiple standards, including UL 508A Type 1, 2, 3, 4, 4X, 12, and 13; CSA Type 1, 2, 3, 4, 4X, 12, and 13; and NEMA Type 1, 2, 3, 4, 4X, 12, and 13. They meet IEC 60529 IP66 rating, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments, with operating temperatures ranging from -40°C to 130°C.
What certifications and standards do Panduit products comply with?
Panduit products are certified to multiple critical industry standards, including UL (Underwriters Laboratories) in the USA and Canada, CSA (Canadian Standard Association), EN IEC 61386, LVD 2006/G5/EC, and ARRA standards. Our products meet rigorous certifications for electrical safety, environmental compliance (WEEE and RoHS), and are designed to perform in extreme temperatures ranging from -55°C to 105°C, making them suitable for demanding industrial environments.
What industries and applications are Panduit products used for?
Panduit products are engineered for critical applications across multiple industries, including commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety-critical environments. Their solutions span electrical infrastructure, wire management, cable ties, power connectors, and safety systems designed to withstand extreme conditions like high vibration, temperature variations, UV exposure, and corrosive agents. Key industries include solar and wind energy, aerospace, heavy trucking, military, commercial transportation, and industrial manufacturing.
What are the main product lines offered by Panduit?
Panduit offers a comprehensive range of electrical infrastructure products including power connectors, cable ties, grounding connectors, identification products, safety solutions, terminals, cable cleats, wiring duct, and cable tie accessories. These products are engineered for industrial environments across multiple sectors like commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications.
What are the key features of Panduit products?
Panduit products are engineered for robust performance in heavy-duty industrial environments, featuring a comprehensive range of solutions including cable ties, power connectors, terminals, and identification products. Key features include proven quality performance, subject matter expertise, and customer-driven innovation across multiple industrial sectors such as commercial construction, food and beverage, oil and gas, renewable energy, transportation, and safety applications. The product line is designed to maximize productivity, reliability, and safety while meeting stringent industry standards.
What is Panduit's warranty policy?
Panduit provides a comprehensive Limited Product Warranty that can be fully reviewed on their official website at www.panduit.com/warranty. All Panduit products are subject to the terms, conditions, and limitations of this current warranty. Customers are advised to review the specific warranty details for their particular product, as Panduit requires buyers to determine product suitability for their intended use and assumes all associated risks.
What technical support does Panduit offer?
Panduit offers comprehensive technical support through their dedicated customer service team, accessible via phone at 1-800-777-3300. They provide expert assistance for their full range of industrial infrastructure products, including cable ties, power connectors, terminals, and identification solutions. Customers can also access additional technical resources and product information through their website at www.panduit.com.
What accessories are available for Panduit products?
Panduit offers a wide range of accessories across multiple product lines, including cable ties, cable tie accessories, cable tie tools, identification products, cable cleats, grounding connectors, and VeriSafe accessories like the VeriSafe Network Module and Insulation Piercing Connectors. For a comprehensive view of all available accessories, customers are recommended to visit www.panduit.com for the full product catalog.
How are Panduit products typically installed?
Panduit products are engineered for comprehensive installation across industrial environments, utilizing specialized tools and techniques for precise mounting. Installation methods vary by product line - from cable ties and power connectors to terminals and identification solutions - but all are designed for robust performance in heavy-duty settings. Technicians typically use Panduit's dedicated installation tools and follow manufacturer guidelines available at www.panduit.com to ensure proper fitting and maximum infrastructure reliability.